
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 3
Page 3.9.4
and
1/3
MAIN GEN
LOW VOLTAGE
an
With GENERATOR selector on ST-BY (after MAIN generator failure), functioning on
ST-BY generator.
1 -
GENERATOR selector
MAIN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
MAIN GENERATOR RESET push-button
Press
. . . . . . . . . . . . . . . . . . . . . . . .
►
Fly the airplane
◄
If MAIN GENERATOR successfully connected :
3 -
Disconnect non-essential systems.
4 -
Voltmeter and ammeter
Monitor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
►
Land as soon as possible
◄
End of procedure
■
If MAIN GENERATOR not successfully connected :
5 -
GENERATOR selector
ST-BY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -
ST-BY GENERATOR RESET push-button
Press
. . . . . . . . . . . . . . . . .
If ST-BY GENERATOR successfully connected :
7 -
Disconnect non-essential systems.
8 -
Voltmeter and ammeter
Monitor
. . . . . . . . . . . . . . . . . . . . . . . . . .
►
Land as soon as possible
◄
End of procedure
■
If ST-BY GENERATOR not successfully connected :
Both generators failure is confirmed.
Return to VMC conditions, if possible.
Continue
►
PIM - DO NOT USE FOR FLIGHT OPERATIONS