Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 0
Page 3.5.5
Smoke elimination
1 -
Oxygen masks and goggles
Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
BLEED switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -
A/C switch
OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -
DUMP switch
Actuate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -
Wait until the differential pressure drops.
6 -
EMERGENCY RAM AIR control knob
Pull
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If smoke decreases :
►
Land as soon as possible
◄
End of procedure
■
If smoke increases :
7 -
EMERGENCY RAM AIR control knob
Push
. . . . . . . . . . . . . . . . . . . . . .
►
Land as soon as possible
◄
End of procedure.