3. Operation
VMCTOPES8D51
3.7.6 Axis emergency stop reset
Operation becomes impossible with MACHINE READY button extinguished, when the emer-
gency stop switch is actuated, just after power on or on other occasion.
At this time, reset the state following the process described below.
1. Be careful of the direction and motion when the overtrav-
eled axis is returned into travel range. Severe collision
can be occured.
Step
Operation
Location
Remark
1
Check AXIS
EMERGENCY STOP
MDI/CRT
devices
– Check the axis and direction
– Operation call lamp lighting
2
Check the machine state
Each axis
– Check collision and
interference, and repair
3
Push MACHINE
READY and EMER-
GENCY RELEASE button
simultaneously
Main OP. panel
– Button lighting
after flickering
– Operation possible
4
Reset
5
Select JOG or HANDLE
mode
6
Return the axis into travel
range with JOG or HAN-
DLE with pushing
MACHINE READY and
EMERGENCY RELEASE
button simultaneously
– Refer to 3.3.11
3.3.12
Inspection/adjustment/maintenance
3 – 34
3
4
5