S0702170K
Page 32
Hydraulic System Troubleshooting, Testing and
Adjustment
TROUBLESHOOTING – CONTROL VALVE
Check control valve problems only after other hydraulic circuit operational tests have been made. Refer to
the “Troubleshooting Baseline Recommendations” procedure. Pump flow, pilot pressure, Negacon
pressure, main relief pressure, and port relief pressure should all be checked before starting to work on the
control valve. Make sure the hydraulic system is topped up to the required level and free of oil leaks or air
in the system that could cause cavitation problems.
Problem
Possible Causes
Remedies
Main Relief Valve
Particulate contamination.
Disassemble, clean main
poppet.
Broken or damaged spring.
Replace.
Adjusting screw loose.
Readjust.
Main poppet sticking.
Repair/replace.
Clogged orifice in pilot passage
to control valve.
Clean/replace.
Cylinder goes down in spool
neutral.
Excessive clearance between
casing and spool.
Replace spool or casing.
Spool does not return to neutral/
sticking spool.
Check secondary pilot pressure.
Spool does not return to neutral
because of dirt or other
contaminants.
Clean.
Broken or damaged spring.
Replace.
Main relief or port relief not
operating properly.
See above.
Impurities in pilot circuit.
Clean.
Cylinder drops before start at
boom up operation
Rod check valve damaged or
clogged.
Clean/replace.
Poppet sticking.
Clean/replace.
Broken or damaged spring.
Replace.
Slow operation or response
Excessive clearance between
spool or casing.
Check pilot pressure and/or
replace spool or casing.
Sticking spool.
Clean/replace.
Broken or damaged spring.
Replace.
Main or port relief valve
damaged.
Check pressure/replace.
Swing priority not operating
correctly.
Sticking spool.
Clean/replace.
Solenoid valve faulty.
Replace.
Boom and arm cylinders do not
perform normally in combined
operation.
Priority valve faulty or spool
sticking.
Check pilot pressure.
Broken or deformed spring.
Replace.
Excess clearance between right
and left casing and valve spool.
Clean/replace.
Clogged spool passage.
Clean/replace, replace filter.
Relief valve malfunctions:
Pressure does not increase at
all.
Main poppet or pilot poppet
stuck open.
Clean/replace.
Содержание Solar 225LC-V
Страница 2: ......
Страница 4: ......
Страница 7: ...1SAFETY ...
Страница 8: ......
Страница 46: ...S0102000 Page 38 Track Excavator Safety ...
Страница 47: ...1SPECIFICATIONS ...
Страница 48: ......
Страница 54: ...S0205015K Page 6 Specifications for Solar 225LC V Return to Master Table of Contents ...
Страница 70: ...S0205015K Page 22 Specifications for Solar 225LC V Return to Master Table of Contents ...
Страница 71: ...1GENERAL MAINTENANCE ...
Страница 72: ......
Страница 86: ...S0302000 Page 14 General Maintenance Procedures ...
Страница 99: ...1UPPER STRUCTURE ...
Страница 100: ......
Страница 102: ...S0402040K Page 2 Cab TABLE OF CONTENTS Removal 3 Installation 6 ...
Страница 110: ...S0403050K Page 2 Counterweight Return to Master Table of Contents TABLE OF CONTENTS General 3 Removal 5 Installation 7 ...
Страница 116: ...S0403050K Page 8 Counterweight Return to Master Table of Contents ...
Страница 140: ...S0407000 Page 6 Swing Bearing ...
Страница 165: ...1LOWER STRUCTURE AND CHASSIS ...
Страница 166: ......
Страница 190: ...S0505030 Page 24 Track Assembly Return to Master Table of Contents 7 Tighten plug 1 Figure 49 Figure 49 ...
Страница 192: ...S0505030 Page 26 Track Assembly Return to Master Table of Contents ...
Страница 193: ...1ENGINE AND DRIVE TRAIN ...
Страница 194: ......
Страница 205: ...S0605060K Page 11 Air Conditioner Face and Defroster ARS1300L Figure 12 ...
Страница 229: ...S0609000 Page 9 Drive Coupling Main Pump Figure 10 DRIVE COUPLING INSTALLATION UCHIDA PUMP ...
Страница 234: ...S0609000 Page 14 Drive Coupling Main Pump ...
Страница 235: ...1HYDRAULICS ...
Страница 236: ......
Страница 249: ...S0702170K Page 13 Hydraulic System Troubleshooting Testing and Adjustment ...
Страница 272: ...S0702170K Page 36 Hydraulic System Troubleshooting Testing and Adjustment ...
Страница 274: ...S0703010K Page 2 Accumulator TABLE OF CONTENTS General Description 3 Specifications 4 ...
Страница 297: ...S0705000 Page 9 Cylinders ...
Страница 301: ...S0705000 Page 13 Cylinders ...
Страница 311: ...S0705000 Page 23 Cylinders ...
Страница 312: ...S0705000 Page 24 Cylinders SLIPPER SEAL JIG ARS4770L A 2 A A 14 B B 40 5 R 1 0 R1 1 0 Figure 10 ...
Страница 315: ...S0705000 Page 27 Cylinders ...
Страница 316: ...S0705000 Page 28 Cylinders SLIPPER SEAL STRAIGHTENING JIG ARS4780L 2 R1 50 25 100 A 15 A 2 5 R 2 C 1 Figure 11 ...
Страница 324: ...S0705000 Page 36 Cylinders 17 Force out pin bushing 1 from body of cylinder Figure 28 ...
Страница 328: ...S0705000 Page 40 Cylinders ...
Страница 335: ...S0707200 Page 7 Swing Motor Return to Master Table of Contents ...
Страница 336: ...S0707200 Page 8 Swing Motor Return to Master Table of Contents PARTS LIST Model Solar 250LC V 255LC V Figure 4 ...
Страница 341: ...S0707200 Page 13 Swing Motor Return to Master Table of Contents SPECIAL TOOLS Figure 6 ...
Страница 358: ...S0707200 Page 30 Swing Motor Return to Master Table of Contents ...
Страница 368: ...S0707330 Page 10 Travel Motor With Gearbox GM35VL Return to Master Table of Contents TRAVEL MOTOR PARTS LIST Figure 12 ...
Страница 424: ...S0708320 Page 12 Main Pump With Regulator Return to Master Table of Contents PARTS LIST Main Pump Figure 13 ...
Страница 426: ...S0708320 Page 14 Main Pump With Regulator Return to Master Table of Contents Pump Regulator Figure 14 ...
Страница 432: ...S0708320 Page 20 Main Pump With Regulator Return to Master Table of Contents Model SOLAR 225LC V BBS0030L Figure 16 ...
Страница 452: ...S0708320 Page 40 Main Pump With Regulator Return to Master Table of Contents ...
Страница 458: ...S0709401K Page 6 Main Control Valve Kayaba Figure 1 ...
Страница 459: ...S0709401K Page 7 Main Control Valve Kayaba Figure 2 ...
Страница 461: ...S0709401K Page 9 Main Control Valve Kayaba ...
Страница 463: ...S0709401K Page 11 Main Control Valve Kayaba Figure 4 ...
Страница 475: ...S0709401K Page 23 Main Control Valve Kayaba Figure 16 ...
Страница 508: ...S0709401K Page 56 Main Control Valve Kayaba Figure 54 ...
Страница 558: ...S0792105K Page 4 Hydraulic Schematic Solar 225LC V 225NLC V Return to Master Table of Contents SOLAR 225LC V Figure 2 ...
Страница 559: ...S0792105K Page 5 Hydraulic Schematic Solar 225LC V 225NLC V Return to Master Table of Contents BBS0070L SOLAR 225LC V ...
Страница 560: ...S0792105K Page 6 Hydraulic Schematic Solar 225LC V 225NLC V Return to Master Table of Contents SOLAR 225NLC V Figure 3 ...
Страница 561: ...S0792105K Page 7 Hydraulic Schematic Solar 225LC V 225NLC V Return to Master Table of Contents BDS0110L SOLAR 225NLC V ...
Страница 562: ...S0792105K Page 8 Hydraulic Schematic Solar 225LC V 225NLC V Return to Master Table of Contents ...
Страница 563: ...1ELECTRICAL SYSTEM ...
Страница 564: ......
Страница 618: ...S0802220K Page 54 Electrical System ...
Страница 637: ...S0802220K Page 73 Electrical System ...
Страница 644: ...S0892105K Page 4 Electrical Schematic Solar 225LC V 225NLC V Return to Master Table of Contents SOLAR 225LC V Figure 2 ...
Страница 647: ...S0892105K Page 7 Electrical Schematic Solar 225LC V 225NLC V Return to Master Table of Contents BDS0190L S225NLC V ...
Страница 648: ...S0892105K Page 8 Electrical Schematic Solar 225LC V 225NLC V Return to Master Table of Contents ...
Страница 649: ...1ATTACHMENTS ...
Страница 650: ......
Страница 665: ...S0904015K Page 7 Bucket 5 Roll the new O ring 1 Figure 9 into the O ring groove BBO0022L 1 Figure 9 ...
Страница 670: ......