1. CIRCUIT CHECK PROCEDURE
1) Low Voltage Transformer (DMR-210P) Check
The low voltage transformer is located on the PCB
Measuring condition : Input voltage : 120 V
Frequency : 60Hz
2) Voltage Check
- KEY CHECK POINT
- CHECK METHOD
PRINTED CIRCUIT BOARD
Voltage
Terminal
6 - 7
8 - 10
LOAD
AC 17V
AC 2.6V
NO LOAD
AC 20V
AC 3.1V
NOTE :
Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source
voltage.
NOTE :
The allowable tolerance of the secondary voltage is within 5% of normal voltage.
NOTE :
Each measure point must be measured with GND points.
NO
CHECK POINT
REMARK
1
IC1 PIN 63, 64
+5VDC
2
IC1 PIN 25
–24VDC
3
IC1 PIN 38
4
IC1 PIN 33 OR 34
5
DP1 PIN 1, 2 & PIN 32, 33
2.6 VAC (DISPLAY FILAMENT VOLTAGE)
NO
MEASURE POINT (page 55)
WAVE FORM
REMEDY
REMARK
1
MP1
DC +5V±0.25
REPLACE Q5, EC1, C8, ZD4
NO LOAD
2
MP2
DC +24V±1.0
REPLACE EC6, R28, D21~D24
NO LOAD
3
MP3
DC -24V±1.0
REPLACE ZD3, ZD6, C7, EC4
NO LOAD
T : 16.67ms (60Hz)
T : 250 ns