23
CONDITION
CHECK
RESULT
Continuity
Continuity in
backward
direction
0 Ω
or
¡Ä
No
Continuity
No
Continuity
0 V
Approx
15 VDC
CAUSE
Defective
high voltage
transformer
Defective
high voltage
rectifier
Defective
magnetron
Defective
magnetron
Defective
high voltage
transformer
Defective
high voltage
transformer
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY1) or open
relay coil
REMEDY
Replace
Replace
Replace
Replace
Replace
Replace
Replace
Replace
No microwave
oscillation
Check continuity of high
voltage rectifier in
forward and backward
direction with DC
megger
Check continuity of high
voltage capacitor
terminals with wires
removed
Connect megger leads to
magnetron terminal and
magnetron body
Check resistance of
primary and secondary
coil of high voltage
transformer
Check continuity of
magnetron with wires
removed
Check continuity of
filament terminal of high
voltage transformer
Check D.C. voltage
being supplied to
RELAY (RY1) coil
Continuity
TROUBLE SHOOTING GUIDE
(
TROUBLE 3 )
No microwave oscillation even though fan motor rotates.
Содержание KOR-131G0A
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION ...
Страница 29: ...28 WIRING DIAGRAM ...
Страница 31: ...30 MP1 MP2 PRINTED CIRCUIT BOARD Measure Point ...
Страница 33: ...32 PRINTED CIRCUIT BOARD 2 P C B CIRCUIT DIAGRAM ...
Страница 37: ...36 PRINTED CIRCUIT BOARD PRINTED CIRCUIT BOARD MP1 MP2 MP3 Measure Point ...
Страница 40: ...39 PRINTED CIRCUIT BOARD 2 PCB CIRCUIT DIAGRAM ...
Страница 46: ...45 EXPLODED VIEW AND PARTS LIST 2 KOR 131H4 and KOR 131G4 ...
Страница 48: ...47 EXPLODED VIEW AND PARTS LIST 3 KOR 131S4 ...