9
1. By pressing the ‘FRZ. SET’ button.
-15 (Min) , -16, -17, -18, -19 (Medium), -20, -21, -22, -23 (Max)
2. Compressor & Freezer Cooling Fan controlled by each dial ON/OFF point.
3. Freezer compartment ON/OFF diff is 4 degree.
- Freezer ‘Middle’ OFF point is -21 degree.
- If RT <= 13 degree, Freezer ‘Middle’ OFF point is -19 degree. ( 2 degree up )
4. Freezer Step Diff is 1 degree.
( but -15 -> -16 step is 1.8 degree. )
5. Control point at each dial ( Freezer sensing point )
INPUT
CONTROL OBJECT
CONTENTS
1. FRZ. SET
2. Freezer Temperature Sensor
4-2. Freezer temperature control
1. Compressor
2. Freezer Cooling Fan
1 degree
1.8 degree
1 degree
Step Diff
-18
-17
-16
-14.2
-22
-21
-20
-19
Sensor Off
-14
-13
-12
-10.2
-18
-17
-16
-15
Sensor On
RT <= 13C
-20
-19
-18
-16.2
-24
-23
-22
-21
Sensor Off
-16
-15
-14
-12.2
-
-20
-19
-18
-17
Sensor On
Normal
Control
Medium Min
MIN
QUICK
Max
Medium Max
Medium
Temperature
temperature
-18
-17
-16
-15
QUICK
-23
-22
-20
-19
Setting
8th Press
7th Press
6th Press
5th Press
4th Press
3rd Press
2nd Press
1st Press
Initially On
Division
6. Super freeze (QUICK)
- Compressor, Freezer cooling fan is ON without sensing point for 150 min.
- Freezer cooling fan voltage is 14V for 90 min and 12V for 60 min.
- Dial changes into -19C (Medium) after 150 min.
* The temperature can vary depending on the load condition.
Содержание FRS-T24BB
Страница 3: ...3 2 1 External Size 2 EXTERNAL VIEWS...
Страница 5: ...5 Freezer Compartment Refrigerator Compartment 2 3 Cold Air Circulation...
Страница 25: ...25 DIAGRAMA ALAMBRADO...