10
1. By pressing the ‘REF. SET’ button.
8 (Min), 7, 6, 5, 4 (Medium), 3, 2, 1, 0 (Max)
2. Compressor & Refrigerator Cooling Fan controlled by each dial ON/OFF point.
3. Refrigerator compartment ON/OFF diff is 0.5 degree.
- Refrigerator ‘Middle’ OFF point is 0.7 degree.
- If RT <= 13 degree, Freezer ‘Middle’ OFF point is 2.7 degree. ( 2 degree up )
4. Freezer Step Diff is 1 degree.
( but 8 -> 7 step is 2 degree and 1 -> 0 step is 0.5 degree )
5. Weak Refrigeration.
- When sensing weak refrigeration, compressor is ON without Freezer sensing point.
- When Refrigerator sensor reaches sensor Off point, compressor depends upon Freezer sensor.
- Weak Refrigeration sensing ON point : Each dial Off point + 7 degree.
- Weak Refrigeration sensing Off point : same as each dial Off point.
6. Control point at each dial ( Refrigerator sensing point )
INPUT
CONTROL OBJECT
CONTENTS
1. REF. SET
2. Refrigerator Temperature Sensor
4-3. Refrigerator temperature control
1. Compressor
2. Refrigerator Cooling Fan
7. Super cool (QUICK)
- For 40 min.
- Refrigerator cooling fan & Compressor is ON until Refrigerator sensing -7 degree.
- Inter Cooler fan is ON for 10 min. ( When Door opens Inter cooler is off, the remaining time will go on.)
- During QUICK mode the dial setting is same as Max ( 0 degree)
- After 40 min (QUICK mode) the dial changes into Medium ( 4 degree).
1 degree
2 degree
0.5 degree
1 degree
Step Diff
Refrigeration
8.7
9.7
10.7
11.2
2.7
4.7
5.7
6.7
7.7
Sensor
On
Weak
3.7
4.7
5.7
6.2
-2.3
-0.3
0.7
1.7
2.7
Sensor
Off
4.2
5.2
6.2
8.2
-1.8
0.2
1.2
2.2
3.2
Sensor
On
RT <= 13C
1.7
2.7
3.7
4.2
-4.3
-2.3
-1.3
-0.3
0.7
Sensor
Off
2.2
3.2
4.2
6.2
-
-3.8
-1.8
-0.8
0.2
1.2
Sensor
On
Normal
Control
Medium Min
Min
QUICK
Max
Medium Max
Medium
Temperature
temperature
5
6
7
8
QUICK
0
1
2
3
4
Setting
9th
Press
8th
Press
7th
Press
6th
Press
5th
Press
4th
Press
3rd
Press
2nd
Press
1st
Press
Initially
On
Division