11
1. Defrost Mode
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Defrosting Cycle
1. Compressor
2. Freezer - Fan
3. Refrigerator - Fan
4. Defrost - Heater
Pause
Fan-Delay
Heater
Defrosting
Heater
Defrosting
1) Comp, F-fan, R-fan : OFF & D-HTR : ON
2) Time limit
30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start
30 minutes : in case of D1- Error
60 minutes : in normal control state
3) If D-sensor
≥
10
℃
, Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F-fan, R-fan, Heater etc. : OFF
Fan-Delay
Time : 5 minutes
Comp : ON and F-fan, R-fan, Heater : OFF
4-4. Defrost Mode
2.The defrost mode start with the following conditions
1) Total operation time of comp. becomes : 6, 8, 10, 12 hours.
①
Comp. operating rate : more 85%
②
Total door open time : 3 minutes
(Any door, F or R open time is over 3 minutes.)
③
Any error mode : R1, F1, D1, F3, RT/S, Door-switch etc.)
2) Defrosting mode starts unconditionally as long as total compressor work time is
12 hours, even if the above conditions 1) are not satisfied.
3) Defrosting mode starts immediately as long as total time of [comp. ON +
comp. OFF] is over 60 hours, even if the above 1) and 2) conditions are not
satisfied.
3. Electrical Devices control Table
30 Min (Error)
(Max)
5 Min
7 Min
60 Min
Time limit
OFF
OFF
ON
Defrost Heater
OFF
OFF
OFF
Refrigerator Fan
OFF
OFF
OFF
Freezer Fan
ON
OFF
OFF
Compressor
Fan Delay
Pause
Defrost
Division