34
6-4. LE (Lock Error) - Door opening error
1) Conditions of Occurrence
①
When intending to begin cycle by pressing start/ temporary stop button while door is opened
2) All LEDs are turned off and 'LE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-5. E1 - Water level detection error
1) Conditions of Occurrence
①
In case water level is below reset or overflow is detected in line test mode
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E1' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
6-6. E2 - Overflow error
1) Conditions of Occurrence
①
In case water level in water tank is above overflow level due to continuous operation of water supply
valve
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E2' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
Содержание DWD-L100 Series
Страница 10: ...8 B01 B02 B03 B05 B04 B08 B07 B06 B10 B09 B11 B12 B13 B14 3 INLET BOX AS...
Страница 12: ...10 4 CABINET F ASSY C12 C01 C02 C03 C14 C15 C06 C07 C04 C05 C11 C08 C09 C10 C13 1st Model...
Страница 14: ...12 5 DOOR AS C11 C01 C02 C03 C12 C10 C09 C04 C07 C05 C06 C08 2st Model...
Страница 20: ...18 8 DUCT B for dry model E01 E15 E13 E14 E12 E11 E04 E07 E06 E10 E08 E03 E05 E02 E09...
Страница 22: ...20 9 CABINET AS F07 F01 F03 F02 F04 F05 F10 F09 F08 F06 1 F06 2 F06 F11 F12 F13...
Страница 41: ...39 39 6 WIRINGDIAGRAM DWC LD S...
Страница 42: ...40 40 DWD LD S...
Страница 43: ...41 DWC LU S...
Страница 44: ...42 DWD LU S...