background image

25

Wool

Anti-

Blanket Quick 30 Drum Drying Small Wash Memory

Small

Allergy

Middle

Middle

High

Small

Default Wash Temp

Cold

Cold

30°C

Cold

40°C

Soak

30min

Water Supply

2min

40min
35min
30min

Washing

25min
20min
15min
10min

8min

Drain

1min

Balancing Spin

2min

Mid.Spin

3min

Water Supply

2min

Rinse 1

3min

Drain

1min

Balancing Spin

2min

Mid.Spin

3min

Water Supply

2min

Rinse 2

3min

Drain

1min

Balancing Spin

2min

Mid.Spin

3min

Water Supply

2min

Rinse 3

3min

Drain

1min

Balancing Spin

2min

7min

Mid.Spin

5min
3min

Crease care

60sec

Dry

40min
30min

Cooling

5min

END

10min

Crease care

30min

Crease care

60sec

END

10sec

Remain Time Display

49

35

1:11

32

1:51

54

NOTE

W

a
s
h

i

n
g

R

i

n
s
e

S
p

i

n

D
R
Y

END

1. Anti-Allergy Course is for removing scent and sterilizing clothes by controlling temp.

about 70~80°C with heater dry on for 35 min.

DIVISION

Default Wash Temp

Содержание DWD-E113R

Страница 1: ...DRUM WASHING MACHINE DEC 2006 DWD E115R DWD E113R WDE115R001 ...

Страница 2: ...DRUM 2 2 SPECIFICATION OF DRUM WASHING MACHINE 6 3 VERIFICATION OF DRUM ASSY 8 4 SEQUENCE CHART OF PCB 24 5 TROUBLE SHOOTING 34 6 WIRING DIAGRAM 49 7 TROUBLE SHOOTING REGARDING DRAIN 50 8 INSTALLATION GUIDE 51 9 ATTENTION POINT WITH SERVICING 53 ...

Страница 3: ... NANO technology Sterilizing up to 99 9 No damage and entanglement but excellent washability 4way savings noise vibration washing times energy Self cleaning course of Drum Good washing performance with heating system Condensing dry system with saving energy Big door glass with easy laundry take in out The higest spin speed 1200rpm Superior Interior Design 2 Salespointofourwasher ...

Страница 4: ...3 DD CONTROL DIRECT DRIVE SYSTEM BLDC MOTOR 3 THEDIRECTDRIVESYSTEMOFDRUMWASHINGMACHINE TUB DRUM LIFTER WASH BLDC DRAIN PUMP MOTOR ...

Страница 5: ...W ADDING CLOTHES LOCK HINGE DOOR AS GLASS GASKET 7 DRAIN PARTS DRAIN PUMP MOTOR VALVE HOUSING DRAIN HOSE I 6 DRY PARTS HEATER DRY OPTION BLOWER FAN FAN MOTOR BLDC THERMISTOR THERMOSTAT FUSE BI METAL CONDENSING SYSTEM DRY FAN DRIVE GENERATION OF HEATER S HEAT TEMP SENSOR 110 C Off 100 C On OPTION DRAIN PARTS ...

Страница 6: ...SE FILTER POWER CORD 15A 2 DRIVE PARTS BLDC MOTOR DRUM BEARING SPIDER SHAFT TUB WEIGHT BALANCER 4 WASH HEATING WASH HEATER OPTION THERMISTOR 40 C FIXED TEMP CONTROL OPTION 60 C 90 C BOIL 8 SUPPORTER BASE DAMPER AS Right 2 60N Left 1 120N Spring 4 ...

Страница 7: ...ET F ASSY CABINET F AS 1 PANEL F ASSY 2 INLET BOX AS INLET BOX 2 INLET BOX AS 3 WAY INLET VALVE 2 WAY INLET VALVE 1 WAY INLET VALVE 4 CABINET AS 7 DOCT AS DUCT AS 7 DOCT AS DUCT AS 5 BASE U AS 6 TUB ASSY LIFTER AS 6 TUB ASSY 5 FUNCTION ...

Страница 8: ...S 5 BASE U AS PCB MAIN AS 6 TUB ASSY DRUM AS 6 6 6 3 6 4 6 1 6 2 6 8 6 7 6 4 6 5 6 TUB ASSY Parts For Driving 6 1 BLDC ROTOR BLDC MOTOR 6 2 BLDC STATOR 6 3 SHAFT 6 4 BEARING Parts For Transmitting 6 5 SPIDER 6 6 DRUM 6 7 TUB 6 8 BASE ...

Страница 9: ... Digital condensing dry system OPERATION WATER PRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 1 PREMIUM TYPE 2 DRUMWASHINGSPECIFICATIONOFMACHINE 1 EXTERIORDIAGRAM NO PARTSNAME 1 FRAMEDOORO 2 DOOR GLASS PLATE 3 DOOR GLASS BAND 4 HANDLEDOORUPPER 5 HANDLE DOOR LOWER 6 HANDLE DOOR COVER 7 PANELOUTER 8 PANELINNER 9 PANEL PLATE 10 BUTTON DIAL OUT 11 BUTTON DIAL IN 12 CASE HANDLE 13 CASE HANDLE PLATE 14 CABIN...

Страница 10: ...TYPE DRUM TYPE DRY TYPE Digital condensing dry system OPERATION WATER PRESSURE 29kPa 784kPa 0 3kgf cm2 8kgf cm2 2 LUXURY TYPE 1 EXTERIORDIAGRAM NO PARTSNAME 1 FRAMEDOORO 2 DOORPLATEGUIDE 3 PROTECTOR GLASS 4 HANDLE DOOR UPPER 5 HANDLE DOOR LOWER 6 PANELOUTER 7 PANELINNER 8 BUTTONSELECT 9 BUTTONPOWER 10 BUTTON DIAL OUT 11 BUTTON DIAL IN 12 CASE HANDLE 13 WINDOW DISPLAY 14 CABINET F OUTER 15 COVERPUM...

Страница 11: ...10RP 1 A03 CASEPCBF 3611143600 HIPS 1 A04 PCBAS PRPSSW2D21 DWD E110RFRONTPCBASSY 1 A05 BUTTONDIALAS 3616634700 130RP SBUTTONDIALAS 1 A06 HOLDERDIAL 3613052100 HIPS 1 A07 CASEHANDLE 3611143800 ABS 1 A08 CASEHANDLEPLATE 3611143900 ACRYLIC 1 A09 PANELINNER 3614286200 ABS 1 A10 PCBAS PRPSSW2D22 DWD E110RTOUCHPCBASSY 1 A11 PANELPLATE 3614286300 ACRYLIC 1 1 PREMIUM TYPE ...

Страница 12: ...E PCB F 3611143600 HIPS 1 A04 PCB AS PRPSSW2D24 DWD E112R FRONT PCB ASSY 1 A05 BUTTON DIAL AS 3616634700 130RP S BUTTON DIAL AS 1 A06 HOLDER DIAL 3613052100 HIPS 1 A07 CASE HANDLE 3611143800 ABS 1 A08 PANEL INNER 3614286400 ABS 1 A09 BUTTON POWER 3616635600 ABS 1 A10 BUTTON SELECT 3616635500 ABS 1 A11 WINDOW DISPLAY 3615504700 ABS 1 2 LUXURY TYPE ...

Страница 13: ...INLET 3613271000 EPDM 1 B07 HOSE A 3613266640 EPDM ID 10 L 280MM MAIN B110RN 1 B08 HOSE B 3613266740 EPDM ID 10 L 370MM HOT B110RN 1 B09 HOSE C 3613267040 EPDM ID 10 L 160MM SHOWER B110RN 1 B10 PIPE JOINT HOSE INLET 3614413300 PP 1 B11 HOSE SHOWER 3613270100 EPDM ID 8 5 OD 12 5 GASKET SHOWER 1 B12 CLAMP HOSE 3611205800 100H ID 13 8 W 10 0 0 9T 8 B13 VALVE INLET 3615415050 220 240V 3WAY RINSE GUIDE...

Страница 14: ...11 3 CABINETFASSY 1 PREMIUM TYPE ...

Страница 15: ...50V16A BITRON 1 C06 FRAMEDOORO 3612207300 ABS 1 C07 FRAMEDOORI 3612207400 ABS 1 C08 DOORGLASSPLATE 36117ABJ00 GLASS 1 C09 DOORGLASS 361A110600 GLASS DWD 100DR 1 C10 CUSHIONDOOR 3611568400 DWD E110RP 3 C11 HOOKDOOR 3613100900 ZNDC 1 C12 PINHANDLE 3618200100 SUS D3 0 1 C13 DOORGLASSBAND 36117ABK00 ABS 1 C14 HANDLEDOORCOVER 3612610200 ABS 1 C15 HANDLEDOORUPPER 3612610000 ABS 1 C16 HANDLEDOORLOWER 361...

Страница 16: ...13 3 CABINETFASSY 2 LUXURY TYPE ...

Страница 17: ...47200 DL S1 250V16A BITRON 1 C06 FRAMEDOORO 3612207800 ABS 1 C07 FRAMEDOORI 3612207400 ABS 1 C08 DOORPLATEGUIDE 36117ABL00 ABS 1 C09 PROTECTORGLASS 3618304201 ABSTRANSPARENT 1 C10 DOORGLASS 361A110600 GLASS DWD 100DR 1 C11 CUSHIONDOOR 3611568400 DWD E110RP 3 C12 HOOKDOOR 3613100900 ZNDC 1 C13 PINHANDLE 3618200100 SUS D3 0 1 C14 HANDLEDOORUPPER 3612610300 ABS 1 C15 HANDLEDOORLOWER 3612610100 ABS 1 ...

Страница 18: ...15 4 CABINETASSY ...

Страница 19: ...DR 1 D04 CABINET 3610810900 SGCD1 0 8 925 7 1922 PAINTING DWD 110RP 1 D05 COVERBACKAS 3611425510 COVERBACK PADCABINETAS 1 D06 STOPPERSPRING 3615202200 POM DWD 100DR 4 D07 FIXTUREPLATE 3612008000 130RP POM 4 D08 FRAMEUPPER 3612207600 SBHG1 2T 1 D09 FRAMELOWER 3612207500 SBHG1 2T 1 D10 HANDLECABINET 3612608100 PP DWD 100DR 4 D11 SPECIALBOLT 3616029100 M4X12 5MACHINE DWD 100DR 4 ...

Страница 20: ...17 5 BASEUAS ...

Страница 21: ...1910 PP DWD 100DR 1 E05 SUPPORTERLEG 3615303600 PO 3 0T 4 E06 FIXTURELEG 3612006400 ABS DWD 100DR 4 E07 SPECIALBOLT 3616029000 10X1 25 51MM 4 E08 FOOT 3612100600 BUTYL DWD 100DR 4 E09 ABSORBERBASE 3610115200 PEFOAM 8X1425 20T 1 E10 DAMPERFRICTION 361A700130 60NAKSST 170 260DL 197 5LOWNOISE 2 E11 DAMPERFRICTION 361A700120 120NAKSST 170 260DL 197 5LOWNOISE 1 E12 DAMPERPIN 361A700200 AKSD 14 5 3 E13 ...

Страница 22: ...19 6 TUBASSY ...

Страница 23: ... 361A400350 DWD A11 S LIFTBODY FILTERAS 3 F17 SPIDERAS 361A300200 11KG 1 F18 GASKETTUB 3612321100 EPDMFORM 1 F19 DRAINMOTOR 36196TAJ00 SV MX7T20D220 50 60ST23 56 5 1 F20 VALVEDRAINAS 3615415100 DWD 100DR 1 F21 AIRTRAPAS 3610AAR101 110RP HOSE TRAP 1 F22 TUBREAR 3618820501 FRPPFH7300GM 1 F23 BEARINGINNER 3616303100 6206ZFAB 1 F24 BEARINGHOUSING 3616303000 ALDC 1 F25 BEARINGOUTER 3616303200 6205ZFAG ...

Страница 24: ...21 7 DUCTBAS DUCTPIPEAS ...

Страница 25: ...61A201800 ALDC 1 G11 PACKING THERMOSTAT 3614009900 SILICON DWD 100DR 1 G12 SWITCH THERMOSTAT 3619046500 ON120 C OFF150 C 230V 15A VDE 1 G13 HEATER DRY 3612800900 220V2100W23 05OHM6 1W SQINCOLOY8001R1A034001 1 G14 THERMISTOR DRY 361AAAAC00 R40 26 065kΩ R90 4 4278kΩ 1 G15 PACKING RUBBER 3614009800 SILICON DWD 100DR 1 G16 CUSHION DRY 3611562800 NBR DWD 100DR 2 G17 GASKET SEAL A 3612320820 DWD 110RP ø...

Страница 26: ...SY No PARTS NAME PARTS CODE DESCRIPTION Q TY REMARK H01 PLATE T 3614539500 SECD 1 2T 1 H02 LABEL CAUTION 3613553830 DRUM 11KG DRY WASH KOR PVC 95 143 SILK 2 1 H03 LABEL INSTALL 3613555700 ART OPP WATER VALVE STICKER 1 ...

Страница 27: ...2min Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 2min 7min Main Spin 5min 3min Crease care 60sec END 10sec Remain Time Display 1 25 1 30 1 54 2 06 2 16 1 41 1 51 NOTE Pre Wash W a s h i n g R i n s e S p i n END Normal 40degree 40degree 95degree 60degree Heavy Stain White Eco White 1 In the Heavy...

Страница 28: ...in Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min Mid Spin 3min Water Supply 2min Rinse 3 3min Drain 1min Balancing Spin 2min 7min Mid Spin 5min 3min Crease care 60sec Dry 40min 30min Cooling 5min END 10min Crease care 30min Crease care 60sec END 10sec Remain Time Display 49 35 1 11 32 1 51 54 NOTE W a s h i n g R i n s e S p i n D R Y END 1 Anti Allergy Course is for ...

Страница 29: ...Mid Spin 3min Water Supply 2min Rinse 2 3min Drain 1min Balancing Spin 2min 7min Main 5min 3min Crease care 60sec END 10sec Remain Time Display 1 27 1 30 1 35 1 30 NOTE S t e a m W a s h i n g R i n s e S p i n END 1 Cotton Course is for all cooton clothes such as towel diaper and the same course as Normal Steam Course 2 At the Steam Washing Washing Time is 30min for Heavy Stain and 20 min for the...

Страница 30: ...ng the same 45 rpm with left and right direction alternatively 2 Attaching stop Attaching the laundry to drum inside with constant speed 3 Unbalance checking point First step check the U B at 95 rpm 160 rpm Second step check the U B at 95 rpm 350 rpm Third step at 300 rpm if the unbalance data is over the criterion This process will be repeated 4 Drain step Drain at water around 160 rpm 5 After dr...

Страница 31: ...msec pulse until unlock 3 After door locking all parts can work normally 4 After pressing power button if the temperature of wash thermistor is over 50 C or the water level is over the safety level the door will be locked 6 The door will be unlocked immediately after all processes are finished 7 The door can be opened during processing if there is no problem to unlock ...

Страница 32: ...Display LOCK off Dooropen drain fanmotoron coldwatersupply waterlevelis lessthansafetylevel NO NO YES YES Temperatureis lessthan50 C 2 DOOROPENSYSTEM 1Ifaddthelaundryduringwashing pressthedoorunlockbutton 2Dooropensequenceatabnormalcondition ...

Страница 33: ...k mode press TEMP and DRY simultaneously 2 5 The sequence of drain 1 If the checking time to reset point is below 1 min the remaining drain time is 30 sec 2 If the checking time to reset point is over 1 min the remaining drain time is 2 min 3 If the checking time to reset point is over 10 min OE singal will be appeared on PCB 4 If the temperature is over 50 C the water will be supplied to high wat...

Страница 34: ...urnon LOCK signal allprocessisconductingnormaly 2Whenworkingstarts thePCBdisplaysallthesensorconditions 3Inthiscase BLDCMotorisnottested Inordertotestit selectspinorrinse 2 Continoustestingmode 1 Process afterpressing WASH RINSE SPIN buttonsimultaniously press POWER button ALLLEDOn Off1time L C LockClosed R Motorright L MotorLeft F FanMotor H HotV V C ColdV V b pre washV V d dryV V bb bubble h1 HE...

Страница 35: ...pressure is inferior sensor pressure The drain motor dose not work Change the drain motor The drain motor is an inferior product or broke down The fan motor does not work Change the fan motor The fan motor is an inferior product or broke down The PCB ASS Y does not control the fan motor Check the connector or change the PCB ASS Y Water leaks from the tub or the hose drain Check the leak of the tub...

Страница 36: ...mistor wash The water temp is over 45 C in delicate wool course Change the thermistor wash The heater wash dose not work Change the heater wash The water temp doesn t rise over 2 C during 15min The heater dry dose not work Change the heater dry The water temp doesn t rise over 3 C during 8min The heater worked without the water in the tub Check the water level and the heater wash The drain pump fi...

Страница 37: ...y assembled Openthewatertap Cleanthefilter ChangetheInlet Valve Thecontactofthe Connector ChangetheInlet Valve ChangetheSensor Pressure Changethebad parts ChangetheInlet Valve ChangetheInlet Valve IE IE IE IE IE IE IE E2 E2 checkthewatertapopened checktheresistance4320 5280Ω checkthefilter checktheconnector checktheresistance4320 5280Ω checktheconnector checkthepressureswitch checkthehosetornortwi...

Страница 38: ...checkthehosecondition checktheconnectorcondition frequencyCheck refertobelow connectorbroken Checkingmethodofcoilregistance harness connector E2 overflowerror Waterlevelishigherthanoverflowlevelbecauseofcontinuouswatersupply E9 Pressureswitchtrouble thefrequencyislessthan15kHzormorethan30kHzintheprocessing Checking method of the Frequency 1 Power ON 2 First press the DRY button 3 times with pressi...

Страница 39: ...eplaceDOORAS ReplaceDOORS W AssembleConnector InsertReceptacleno 2 orno 3 ReplaceDOORS W Afterdrainingwater openthedoor LE LE LE LE LE LE LE checkthejoiningstatusof connectorbyeye Ticksoundhappen checkthejoiningstatusof connectorbyeye Refertobelowchecking method Refertobelowchecking method Checkwhetherthewater levelisoversafetylevel WhenDoorislocked unlocked thisSolenoidWorking soundisheard Preven...

Страница 40: ...37 2 CheckingmethodofDOORLOCKSWITCH 3 CheckingmethodofDOORLOCKSWITCH 2345 Nono 1 BetweenNo 3 No 4 if156 234Ω itisnormal BetweenViloetandBluewire If156 234Ω itisnormal PIN array ...

Страница 41: ... the resistancebetweentwoendsis23 3 25 7Ω Checkwhetherdisconnectedornot SeeFig A Measuretheresistanceoftwoendsofthesensor if 11 981KΩatR25 itismormal Measuretheresistanceoftwoendsofthesensor if 11 981KΩatR25 itismormal Checkwhetherdisconnectedornot SeeFig B Checkwhetherdisconnectedornot ifnormal the resistancebetweentwoendsis22 3 24 7Ω Shippedout Checkwhetherdisconnectedornot SeeFig B ExcessiveNoi...

Страница 42: ...ing In Wool Lingerie courses sensing temp is over 45 C 6 H6 Abnormal condition of Heater Wash when the temp increase at 10 minutes after heater operation is under 10 C 7 H7 Abnormal condition of Heater Dry when the temp increase at 10 minutes after heater operation is under 10 C 8 H8 Heater Wash Overheating when the temp increase within 30sec after heater operation is over 5 C without water 9 E3 F...

Страница 43: ...DrivingmechanismofBLDCMOTOR BLDCMOTOR MagneticdensityflowofBLDCMotor SequencediagramofBLDCMOTOR 5 MOTOR Rotor Insulator Core Insulator electromagnet generatinghighpowerbyrotator apermanentmagnet andstator multiplecoils ...

Страница 44: ... 6 DRY SYSTEM OPTION E J C D G F I B A H Division Parts Name A DUCTCOVER B FANMOTOR C HEATERDRY D DUCTBLOWER E VALVEINLET DRY F THERMOSTAT Bimetal G THERMISTOR TemperatureSensor H DUCTBUPPER I FANAS J FUSETEMPERATURE ...

Страница 45: ...CT andcondensedinDUCTcontactingWATERSUPPLY condensedwater isextractedthroughDRAINHOUSING Dryfunctionisperformedbycontinuousrepetitionofevaporatingandcondensingcirculationasabove DRY DUCT T Thermistor CONTROL HEATER S TEMPERATURE HEATER FANMOTOR CONDENSING DUCT DRUM DRAIN HOUSING 온도 건조진행구간 예열 구간 DRUM 내부온도 시간 T WATER SUPPLY INSIDE TEMPERATURE OF DRUM TIME DRYINGPROCESS ZONE TEMP PREHEATING ZONE ...

Страница 46: ...drying time is 166 min Drying Time is 150 210min according to Load Sensing Data STRONG Heater control temperature is 100 C On 110 C Off drying time is 216 min Drying Time is 210 270min according to Load Sensing Data SELECTING TIME Heater control temperature is 100 C On 110 C Off customer can select the drying time 1Hr 2Hr 3Hr out of 1 00 2 00 3 00 Inordertocheckthedryingtemperatureduringprocessgoi...

Страница 47: ...ingtheairtemperature FAILUREMODE Theaircannotbeheatedeventhoughwaterissupplied H1 shotorcut off H3 airtemp isreachedover150 C CHECKINGMETHOD Checktheresistanceofthermistor replacewithnewone FUSETEMPERATURE function protectingfromthefirehazardoroverheating ifthetemp risesover128 C powersupplywillbecut off Pictures FAILUREMODE Dryisnotperformed CHECKINGMETHOD Checkiffuseisshort andreplacewithnewone ...

Страница 48: ... C andreoperatingheater byconnectingheaterpowersupplyifthetemperaturefallsunder120 C OPERATINGTEMPERATURE PICTURE UNITFANMOTOR function circulatingtheinsideairduringdryprocess SPEC PICTURE FAILUREMODE E3shown FANMOTORcannotwork CHECKINGMETHOD ChecktheFANMOTORisshort andreplacewithnewone OPENTEMPERATURE OFF 150 C 5 C CLOSETEMPERATURE ON 120 C 5 C ITEMS SPEC RATINGVOLTAGE 24V RPM MOTOR 3700 10 DUCT ...

Страница 49: ...donebeforethedryhadstarted Situation PCBshows H1 or H3 cause Thermistorisbroken Thermistorisshortorcut off countermeasures replacetheThermistor part name checking point checking results jurge repair method BELLOWS DUCT VALVE INLET Condensing HOSE clogging bellowsduct nowatersupply frominletvalve heaterwas overheated owingtopoorair circulation VALVEINLET connectorslipped out VALVEINLET broken ill c...

Страница 50: ...heater replacetheFusetemp checking point part name checking results repaire method HEATER SENSORTEMP FUSE TEMP dryHeaterisshortorcut off Thermistorisshortorcut off FUSETEMPERATUREiscut off replacethe dryHeater replacethe Thermistor replacethe FUSE TEMPERATURE THERMISTOR HEATER DRY FUSE TEMPERATURE ...

Страница 51: ...ure replace fanmotor 1DisassembleDuctCoverAsfromDuctBAs Screw4EA 2DisassembleFANASFromDuctCoverAs Fixedby8mmNUT 3DisassembletheFANMOTOR SCREW3EA parts Control time MOTOR 10 sec On 10sec Off DRAIN MOTOR Continous working FAN MOTOR Continous working DRY HEATER 100 C On 110 C Off INLET VALVE 5sec On 20sec Off Remarks controltimesofeachpartsduringdryprocess DUCTCOVERAS FixedBy8mmNUT ...

Страница 52: ...49 DOUBLE VALVE BUBBLE DOUBLE VALVE N BUBBLE 6 WIRING DIAGRAM OPTION OPTION DRAIN PUMP Or DRAIN MOTOR DRAIN PUMP Or DRAIN MOTOR OPTION OPTION ...

Страница 53: ...ingdrainduring10min ThewaterlevelcannotreachtoRESETPOINTduring10minofdrain Checking Methods Check the hose drain O condition twisted or frozen Check the hose drain O condition blocked DRAIN MOTOR is broken Replacing methods replace HOSE DRAIN O clean the inside of Filter replace DRAIN MOTOR ...

Страница 54: ... AS by turning CCW direction Please keep FIXTURE UP DOWN AS for later use When fixing FIXTURE UP DOWN AS turn it CW direction PARTS NAME FIXTUREUP DOWNAS UNIT SERVICE WRENCH LEG ADJUST AS REMARKS SPECIAL SCREW UP L 109mm SPECIAL SCREW DOWN L 145mm 1Usethisparttoremove FIXTUREUP DOWN 2Adjustlegwiththispart FIGURES SPECIAL SCREW UP FIXTURE UP FIXTURE DOWN FOOT FIXTURE LEG CAP HOLDER SPECIAL SCREW DO...

Страница 55: ...singLEGADJUSTAS Adjusting Method Remarks If turned CW the LEG ADJUST AS moves the washer upward If turned CCW the LEG ADJUST AS moves the washer downward 5Afteradjustinglevel fixSPECIALBOLT Adjusting Method Remarks Please fix the SPECIAL BOLT by rotating it CCW in order to prevent washer vibration ...

Страница 56: ...ingconditionbetween fixtureheateristight littlegaponleft right Atfasteningthenutforfixingtheheaterwash keeptheprotrusionlength ofboltto10 12mm ifunder10mm watercanleak andifover12mm fixtureheatercan deform 7 Replacing ThermistorWash UnfastentheNutforfixingheater replacethethermistor and ThermistorWash fastenthenutforfixingheater 8 Assembling HingeDoor AtfasteningscrewforfixingDoorAS becarefulsotha...

Страница 57: ...2006 12 DRUM WASHING MACHINE DAEWOO ELECTRONICS CORP 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC ...

Отзывы: