![Daewoo DWD-E113R Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/daewoo/dwd-e113r/dwd-e113r_service-manual_499136038.webp)
35
2) PRESSURE SWITCH
TROUBLE
SITUATION
CAUSE
CHECK POINT
SOLUTION
PCB
ERROR MODE
continuously
water supply
"E9"
ERROR
inlet valve is normal,
but continuous water
supply
water level frequence
below 15kHz or over
30kHz
bellows problem
hose problem
clogged hose
connector slipped out
pressure switch broken
connector short
change the
pressure switch
change the hose
change the hose
remove the alien
reconnecting
change the
pressure switch
"E2"
"E2"
"E2"
"E2"
"E9"
"E9"
"E9"
frequency Check : refer to below
frequency Check : refer to below
check the fine hole
check the hose condition
check the connector condition
frequency Check : refer to below
connector broken
Checking method of coil registance, harness, connector.
* E2 : overflow error ;Water level is higher than overflow level because of continuous water supply.
E9 : Pressure switch trouble, the frequency is less than 15kHz or more than 30kHz in the processing.
■
Checking method of the Frequency
1
Power ON
2
First, press the “DRY” button 3 times with pressing
the “WASH” button. The frequency of Air status will
be appeared.
ex) 623
➝
26.23kHz.
3
Press “TEMP” button
1 time: water supply
2 times: stop the water supply
3 times: start the drain
4 times: stop the drain
5 times: return to Air status mode
GROUND(GRAY)
OUTPUT
SIGNAL(WHITE)
INPUT SIGNAL
(PINK)
"12P" WHITE CONNECTOR
Содержание DWD-E113R
Страница 1: ...DRUM WASHING MACHINE DEC 2006 DWD E115R DWD E113R WDE115R001 ...
Страница 14: ...11 3 CABINETFASSY 1 PREMIUM TYPE ...
Страница 16: ...13 3 CABINETFASSY 2 LUXURY TYPE ...
Страница 18: ...15 4 CABINETASSY ...
Страница 20: ...17 5 BASEUAS ...
Страница 22: ...19 6 TUBASSY ...
Страница 24: ...21 7 DUCTBAS DUCTPIPEAS ...