45
✦
SWITCH THERMOSTAT(BIMETAL)
function : control the duct temperature, if the temp reached over 150°C, all power supply will be cut. and if the temp go down
120°C the power will be ON.
protecting overheating by cutting off heater power supply if the temperature rises over 150°C, and reoperating heater
by connecting heater power supply if the temperature falls under 120°C.
• OPERATING TEMPERATURE
• PICTURE
✦
UNIT FAN MOTOR
function : circulating the inside air during dry process.
• SPEC
• PICTURE
• FAILURE MODE : * E3 shown : FAN MOTOR cannot work.
• CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.
OPEN TEMPERATURE(OFF)
150°C ± 5°C
CLOSE TEMPERATURE(ON)
120°C ± 5°C
ITEMS
SPEC
RATING VOLTAGE
24V
RPM
MOTOR
3700 ± 10%
DUCT FAN AS
1900 ± 10%
ROTAING DIRECTION