1. Technical point of some key parts
1-1. Spin Timer
Function
Structure and Principle of Activation
1-2. Drain Pump
The Spin Timer is the switch providing to the Spin Motor(Drain Pump Motor) during the set
spin dry time, and is a spring-type time switch comes on upon turning and those contact
points comes off after the set time.
1) The main shaft turns due to the unwinding force when the spin timer is turned and the
spring timer wound, with that force being delivered through each gear and the spring slowly
unwinding at a speed finally controlled by the angle assembly.
2) The contact point turns ON and the assembly angle is set in motion, which is in the CAM
groove in the OFF state, comes off the groove when the MAIN SHAFT is turned to wind the
spring. The contact point turns OFF, return to CAM groove when the spring unwind
completely.
Drain pump is designed to drain the water in selecting drain, spinning and water level being
high. Draining capacity is 18l/min. when the drain hose is 1.5m height.
a) Drain
: The Drain Pump is turned on when the Drain Selector Knob is set to "DRAIN" while
the Wash Timer is ON. In this case the Drain Select Knob open the Drain Valve and drain
time can be controlled by Wash Timer.
b) Spinning
: The POWER is provided to Spin Motor and the Drain Pump Motor by Spin
Timer so that the water is drained simultaneously with spinning.