30
1-2) PLAYBACK PHASE Adjustment
• Adjustment Procedure
1. Preparation
1) Play back the Test tape (Color Bar).
2) Connect scope's connector to PY 09
3) Set the Oscilloscope to the chop mode.
Connect CH1 to the H/SW(PY09) and CH2 to the V-OUT(PY09) and trigger the scope with the signal from CH1.
2. Adjustment
1) Adjust RN90 to position the rising edge of SW PULSE at 6.5H from the V-SYNC.
Mode
Adjustment parts
Check point
Test equipments
Test tape
Input signal
Play
RN90
RY05
Oscilloscope
DN-1
Location of Adjustment Parts
Observation Waveform
MAIN PCB
Horizontal Axis : 100µS/DIV
Vertical Axis : CH1 : SW30, CH2:V.OUT
DECK A'S
PY09
PY05
Y/C
BOARD
⊕
RN90