background image

i

nsTallaTion

 s

peCifiCaTions

NOTES:

1.  If cabinet storage space is to be provided directly 

above the cooktop, the risk of personal injury 

may be reduced by installing a ventilating hood 

that projects horizontally a minimum of 5 inches 

beyond the face of the cabinets.

2.  Allow a minimum 1/4 inch clearance between 

the bottom of the cooktop chassis and all 

combustible surfaces, including the upper edge of 

a drawer installed below the cooktop.

3.  Access to the underside of the cooktop and the 

junction box must be provided for inspection and 

service.

4.  A fixed shelf should not be installed below the 

cooktop.

5.  Clearance inside the cabinet must allow for proper 

side mounting bracket installation.

6.  All models are designed for 24” (610mm) 

minimum base cabinet depth.

7.  The maximum depth of cabinets installed above 

cooktop is 13 inches (330mm).

Plan the installation so that the electrical connection, gas shut-off 

valve, and pressure regulator are accessible from the front of the 

cabinet.

Model

“A”

Minimum

“A”

Recommended

PGM304-1 30” (762mm)

36” (914mm)

PGM365-1 36” (914mm)

42” (1067mm)

Model

“B”

Minimum

PGM304-1

29” (737mm)

PGM365-1

35 1/4” (895mm)

13"

(330mm)

Maximum

A

3 1/8"

(79mm)

18"

(457mm)

Minimum

30"

(762mm)

Minimum

Clearances to Combustibles

1/4” (6mm)

Mimimum clearance

to combustible

surfaces

B

Under Cabinet Clearances

g

as

 

and

 e

leCTRiCal

 s

upply

R

equiRemenTs

The PGM cooktops are supplied with a factory installed three-

prong, grounding plug.

It is the owner's responsibility to ensure that the electrical 

connection of this appliance is performed by a qualified 

electrician. The electrical installation, including minimum supply 

wire size and grounding, must be done in accordance with 

National Electric Code ANSI/ NFPA 70* and local codes and 

ordinances. 

*A copy of this standard may be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02269-9101

NOTES:

1.  All gas cooktops have the utilities located in the 

back right corner as you face the front of the 

appliance.

2.  Each cooktop ships with a factory regulator in the 

box.

Check your local building codes for the proper method of 

installation. In the absence of local codes, this appliance should 

be installed in accordance with the National Fuel Gas Code ANSI 

Z223.1/NFPA 54. Be certain that the appliance being installed is 

correct for the gas service being provided. Refer to the data plate 

located on the side of the cooktop chassis.

The correct voltage, frequency and amperage must be supplied to 

the appliance from an isolated, grounded circuit which is protected 

by a properly sized circuit breaker or time-delay fuse.

The cooktop must be connected to the power supply with copper 

wire only. The use of aluminum wire may result in unsatisfactory 

connections. Flexible armored or non-metallic, sheathed copper 

cable (with a grounding wire) should be used to supply electrical 

power to the junction box or receptacle. 

The cooktop’s factory-equipped, three-prong grounding plug must 

be inserted into a mating grounding-type receptacle in accordance 

with National Electric Code and applicable state, municipal and 

local codes.

Be certain to locate the junction box or electrical outlet so the 

electrical supply may be easily disconnected in the event that 

service becomes necessary. Also, provide extra slack in the cable 
to allow the cooktop to be removed for servicing.

g

as

 s

upply

 R

equiRemenTs

e

leCTRiCal

 R

equiRemenTs

g

as

 

and

 e

leCTRiCal

 s

upply

R

equiRemenTs

Содержание Preference PGM304-1

Страница 1: ...Installation Instructions PGM 1 Cooktops For use with models PGM304 1 versions M B PGM365 1 versions M E M F M G Part No 65476 Rev B...

Страница 2: ......

Страница 3: ...ditions you do not understand Safety Symbols Words Labels DANGER DANGER Immediate hazards which WILL result in severe personal injury or death WARNING WARNING Hazards or unsafe practices which COULD r...

Страница 4: ...ids Do not use or attempt to use this appliance in the event of a power failure 4 This unit is designed as a cooking appliance Never use it for warming or heating a room 5 This appliance must not be u...

Страница 5: ...caused by open doors and windows or by HVAC duct outlets Make certain that gas and electrical power can be provided in the selected locations Plan the installation so that all minimum clearances are m...

Страница 6: ...wire size and grounding must be done in accordance with National Electric Code ANSI NFPA 70 and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Associa...

Страница 7: ...cooktop Complete connection of the gas supply to the cooktop by installing a minimum 1 2 inch flexible gas line not included with the cooktop between the pressure regulator and the shut off valve IMP...

Страница 8: ...he appliance data plate before proceeding 3 The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house su...

Страница 9: ...he appliance still does not work contact an authorized DACOR service company If you are unable to locate a DACOR Servicer please contact DACOR at 800 793 0093 or visit us on the web at www dacor com D...

Страница 10: ...NOTES...

Страница 11: ...NOTES...

Страница 12: ...10 NOTES...

Страница 13: ...11 NOTES...

Страница 14: ...12 NOTES...

Страница 15: ...13 NOTES...

Страница 16: ...ained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc 2006 Distinctive Appliances Inc all rights reserved Specifications contained...

Отзывы: