background image

i

nsTallaTion

 i

nsTRuCTions

i

nsTalling

 b

uRneR

 C

omponenTs

Before beginning the test procedure, ensure that the gas supply 

is turned off at the shut-off valve, all cooktop control valves are in 

the “OFF” position, and all burner heads, burner caps, and grates 

are properly positioned on the cooktop.

Depress and rotate one knob at a time counterclockwise to the 

“HIGH” position. Verify that associated burner igniter sparks, then 

return the knob to the “OFF” position. Repeat for all knobs.

IMPORTANT:

When installing the burner components, twist each 

piece back and forth until it drops completely

 

into 

place.  The burners will not operate properly unless 

all of the burner pieces are properly seated.

Burner Components

Remove the burner covers, brass burner heads, burner caps, 

and porcelain grates from their shipping packages. Assemble 

the burners as shown in the diagram. Make sure each piece is 

properly seated. Place each grate onto the cooktop. Be certain 

that the rubber feet are positioned in the locating dimples.

e

leCTRiCal

 C

onneCTion

1.  Ensure that the power supply is disconnected 

before proceeding.

2.  Verify that the power supply matches the 

ratings found on the appliance data plate before 

proceeding.

3.  The complete appliance must be properly 

grounded at all times when electrical power is 

applied.

4.  Do not ground the appliance with the neutral 

(white) house supply wire. A separate ground 

wire must be utilized.

5.   If aluminum house supply wiring is utilized, 

splice the appliance copper wires to the 

aluminum house wiring using special connectors 

designed and agency-certified for joining copper 

and aluminum.

Plug the three-prong plug from the appliance into the properly 

grounded and polarized wall receptacle.

 WARNINGS:

V

eRifying

 p

RopeR

 o

peRaTion

 WARNING:

1.  The cooktop and shut-off valve must be 

disconnected from the gas supply piping during 

any pressure testing exceeding 1/2 pound per 

square inch (3.5 kPA).

2.  The cooktop must be isolated from the gas 

supply piping by closing the shut-off valve 

during any pressure testing at or below 1/2 

pound per square inch (3.5 kPA).

 WARNING:

Never attempt to operate the cooktop with any of the 

burner heads, burner caps, or grates removed.  

Burner Cap

Burner Head

Base

Cross Ring

Skirt

Cap Cover

Wide Side

Down!

Insert Pin on Bottom

of Cross Ring into

Hole on Base

Put Hole in Bottom 

of Burner Head Over Pin 

on Top of Cross Ring

PGM Burner Components

Burner Head

Grate

Cap Cover

Line Up Notch

on Bottom of

Head with Igniter

Single Burner Assembly

Dual Burner Assembly

Base

Содержание Preference PGM304-1

Страница 1: ...Installation Instructions PGM 1 Cooktops For use with models PGM304 1 versions M B PGM365 1 versions M E M F M G Part No 65476 Rev B...

Страница 2: ......

Страница 3: ...ditions you do not understand Safety Symbols Words Labels DANGER DANGER Immediate hazards which WILL result in severe personal injury or death WARNING WARNING Hazards or unsafe practices which COULD r...

Страница 4: ...ids Do not use or attempt to use this appliance in the event of a power failure 4 This unit is designed as a cooking appliance Never use it for warming or heating a room 5 This appliance must not be u...

Страница 5: ...caused by open doors and windows or by HVAC duct outlets Make certain that gas and electrical power can be provided in the selected locations Plan the installation so that all minimum clearances are m...

Страница 6: ...wire size and grounding must be done in accordance with National Electric Code ANSI NFPA 70 and local codes and ordinances A copy of this standard may be obtained from National Fire Protection Associa...

Страница 7: ...cooktop Complete connection of the gas supply to the cooktop by installing a minimum 1 2 inch flexible gas line not included with the cooktop between the pressure regulator and the shut off valve IMP...

Страница 8: ...he appliance data plate before proceeding 3 The complete appliance must be properly grounded at all times when electrical power is applied 4 Do not ground the appliance with the neutral white house su...

Страница 9: ...he appliance still does not work contact an authorized DACOR service company If you are unable to locate a DACOR Servicer please contact DACOR at 800 793 0093 or visit us on the web at www dacor com D...

Страница 10: ...NOTES...

Страница 11: ...NOTES...

Страница 12: ...10 NOTES...

Страница 13: ...11 NOTES...

Страница 14: ...12 NOTES...

Страница 15: ...13 NOTES...

Страница 16: ...ained herein may be copied or used in whole or in part without the express written permission of Distinctive Appliances Inc 2006 Distinctive Appliances Inc all rights reserved Specifications contained...

Отзывы: