Installing the Downdraft Vent in 

the Cutout

1.

 

Cut a hole in the cabinet so the ducting can

 

pass to

the floor/wall for the planned ducting layout. Use the

 

dimensions on 

pa

g

e

s 9, 10 to decide the hole center

line locations. If using the 2” x 16” to 3 1/4” x 10” transi-

tion (REMP and ILHSF blower installations), the hole may

 

need to be enlarged slightly.

2. Gently slide the vent into the rear of the countertop cut-

out with the electrical access panel toward the front.

3. Adjust the anchoring leg height so that the top of the

downdraft vent rests on the counter, then tighten the hex

nuts. Secure the anchoring legs to the cabinet floor with

the provided wood screws.

Adapter Installation: CABP3 Blower

(Optional: MRV3015, MRV3615)

1. Remove the front cover so the AERVCAB cabinet

blower adapter can be installed. Remove and retain the

 

3 wing nuts and 3 flat washers on the front of the unit.

 

Discard the 3 lock washers (which will be replaced). Tilt

 

the cover out and pull up to remove it.

2.

Peel the backing off of some of the foam tape included

 

with the adapter. Attach it to the right and left flanges.

3.

Hold the adapter in front of the opening

, located

 on the 

front of

 

the unit with the adapter’s studs on top

,

 and all 

flanges

 

closest to the downdraft vent chassis.

4.

Slide the adapter’s bottom into the bottom retainer bracket

 

on the downdraft vent at an angle. Attach the adapter

 

using the 3 wing nuts and flat washers removed in Step 1

 

and 3 of the lock washers from the adapter kit.

Installation Instructions

Cover

Front of unit

Rear corner of cutout

(back of downdraft vent)

plumbed down

Exhaust: size and location 

varies with installation type

Front of unit

Floor

Top of vent resting 

on countertop

Electrical access 

panel

Anchor leg

Adapter

Front of unit

Studs

Bottom retainer bracket

Insert bottom 

flange into 

bottom retainer 

bracket

Attach foam

to right/left

flanges

For cabinet cutout, 

please refer to the 

range, rangetop or 

cooktop Installation 

Instructions for more 

details.

Содержание HRV46

Страница 1: ...RV48 ER Includes installation instructions for Dacor cabinet blower CABP3 which is an option for the indicated models Part No 113910 Rev E Use these downdraft vents only with approved Dacor appliances...

Страница 2: ...nd the local electrical inspector s use Customer Assurance Information All specifications subject to change without notice Dacor assumes no liability for such changes 2018 Dacor all rights reserved Mo...

Страница 3: ...an outlet is available for the appliance Do not remove the third ground prong from the power cord use an adapter plug use an extension cord use a damaged power cord Use a ground fault interrupter GFI...

Страница 4: ...s become blocked Do not let foreign objects be sucked into vent holes Clean the filters and all grease laden surfaces often to pre vent grease fires and maintain performance Clean the appli ance only...

Страница 5: ...for exhaust locations and dimensions Maximum height of downdraft vent must not exceed maximum specified counter height for cooking appliance See installation instructions for cooking appliance Total c...

Страница 6: ...down Tolerances 1 16 1 6 mm unless otherwise stated See Pg 9 for exhaust locations dimensions Max height of downdraft must not exceed cooking unit s max specified counter height See cooking unit s ins...

Страница 7: ...ust locations dimensions Max height of downdraft vent must not exceed cooking appliance s max specified counter height See cooking appliance s installation instructions IMPORTANT INSTALLER To ensure t...

Страница 8: ...f the downdraft vent for connecting blower wiring and strain relief Wire the blower to turn on when the downdraft vent is turned on When installing a remote or in line blower run the blower wiring con...

Страница 9: ...de wall Downdraft vent Downdraft vent configured for bottom exhaust Floor Wiring conduit from downdraft to in line blower Cabinet back Front of unit Connection to cabinet blower Blower wiring access h...

Страница 10: ...raft vent s air draw Building codes may require makeup air systems with ven tilation systems that move air greater than the specified movement rate CFM Consult a qualified HVAC specialist when designi...

Страница 11: ...ne of bottom knock out lines up with vertical center line of chassis On 30 and 36 wide models the vertical center line of bottom knock out is offset 3 Side Exhaust Knock Outs 1 5 8 x 16 Bottom Exhaust...

Страница 12: ...onnection center line A Downdraft vent center line Countertop 3 1 4 x 10 duct connection 26 1 4 66 7 cm Exhaust Locations and Side Dimensions for CABP3 Cabinet blower Front Exhaust Dimensions CABP3 Bl...

Страница 13: ...e above parts is 15 ft 15 ft 4 ft 2 ft 36 ft The max amount of straight duct that can be used with a REMP16 and the above parts is 60 ft 34 ft 24 ft Equivalent Number of Feet Nominal Duct Elbows and T...

Страница 14: ...cooktop Install the down draft vent before installing the range or cooktop 2 Start by loosely attaching the anchoring legs to the studs on the left and right sides of the downdraft vent using the prov...

Страница 15: ...ard the 3 lock washers which will be replaced Tilt the cover out and pull up to remove it 2 Peel the backing off of some of the foam tape included with the adapter Attach it to the right and left flan...

Страница 16: ...o right left flanges Adapter New label Existing label ILHSF or REMP Series Blower Installation If using a ILHSF or REMP series blower install it according to the blower installation instructions Duct...

Страница 17: ...cal Installation CABP3 Cabinet Blower Downdraft Vent Electrical Access Panel Front of unit Wire Colors Black Line L White Neutral N Green Ground Gnd Electrical connection from downdraft vent match Wir...

Страница 18: ...aft vent Ensure the downdraft vent supplies power to the blower If the vent will not raise properly or makes a scraping sound check for under counter obstructions If the downdraft vent fails to functi...

Страница 19: ...LK WHT WHT Wiring Diagram All Models CABP3 Cabinet Blower Ratings CABP3 Cabinet blower Airflow Nominal 600 CFM Actual 585 6 CFM At zero inches static pressure Performance varies based on duct system c...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: