Dacor Epicure ED30 Скачать руководство пользователя страница 11

Cabinet Panel Installation 

(Model ID30 Only)

 CAUTION

The provided mounting screws are designed for 

panels with a thickness of 5/8” to 3/4”. Smaller panels 

may require different mounting hardware to prevent 

damage to the outside surface.
To prevent corrosion and the possibility of the panel 

falling off, use only stainless steel screws.
Failure to construct the custom panel and/or toe kick 

as instructed on the installation template may result 

an improper fit and may prevent the door from closing 

properly.

See the included 

Custom Panel Installation 

Template

 (Dacor PN 101394) for complete installation 

instructions and dimensions of the custom panel and if 

desired, a custom toe kick. If the custom cabinet panel 

requires decorative door hardware, mount the hardware 

on the panel before proceeding to the next step.
With the dishwasher door in the closed position, align 

the custom panel flush with the control panel bezel and 

center it on the door front frame. Utilize the keyholes to 

hold the panel.

1.

2.

Align the cabinet panel and, using padded clamps, 

clamp the cabinet panel to the dishwasher front. Slowly 

lower the door and panel to it’s full open position. 

Attach it to the dishwasher door front utilizing the four 

(4) mounting holes. Four (4) #10 stainless steel flat-

head screws are provided for installation of decorative 

panels with a thickness of 5/8” to 3/4”. The four 

mounting holes are located on the inside of the door 

frame. Two holes are near the top of the door panel. 

Two other holes are approximately half way down the 

door panel.

If the door springs to do not work properly due to the 

weight of the panel, adjust the door counterbalance. 

The counterbalance adjustment screws are located on 

the far right side and far left side of the chassis below 

the door.

3.

4.

Installation Instructions

6 7/8" 

(175mm)

18"

(457mm)

1/2"

(13mm)

7/16" (11mm) 

CUSTOM PANEL HOLE 

ALIGNMENT

CUSTOM PANEL INSTALLATION (ID30 ONLY)

Conterbalance

screw

NOTE

: Do not install the toe kick until the dishwasher is 

completely installed and checked for leaks.

NOMINAL CUSTOM PANEL DIMENSIONS FOR ID30

WIDTH

MAXIMUM 

HEIGHT*

MAXIMUM 

THICKNESS

29 7/8” (606 mm)

30” (762 mm)

3/4” (19 mm)

* Dimension without installation of a custom toe kick. See 

included template for further details

Содержание Epicure ED30

Страница 1: ...Installation Instructions 30 Inch Dishwasher For use with models ED30 ID30 Part No 65538 Rev G...

Страница 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved...

Страница 3: ...The customer should not install repair or replace any part of the dishwasher unless specifically recommended in the literature accompanying it A qualified service technician should perform all other s...

Страница 4: ...hin the dishwasher achieve high temperatures Do not touch interior surfaces or items inside the dishwasher during or immediately after use Exercise caution when opening the door Let hot air and steam...

Страница 5: ...30 29 7 8 759mm Cycle ON indicating lights Water Pressure 20 to 120 psi 138 827 kPa Water Temperature 120 F minimum Power Requirements 120 Vac 15 Amp 60 Hz dedicated grounded three prong electrical ou...

Страница 6: ...ocation IMPORTANT Follow all cabinet and countertop minimum dimensions shown below to insure safe operation Plan the installation as shown so that all minimum product dimensions are met or exceeded se...

Страница 7: ...line where it is easily accessible after the dishwasher is installed The dishwasher water inlet hose is equipped with a 3 8 10mm compression fitting The water pressure must be between 20 and 120 psi...

Страница 8: ...er installation Unpack the parts located inside Verify that all required components have been provided If any item is missing or damaged please contact the dealer immediately Do not install a damaged...

Страница 9: ...alled or removed to reduce the likelihood of damage to the power cord or hoses With the assistance of at least one person set the unit in front of the cut out opening Feed the electrical cord drain ho...

Страница 10: ...prevent leaks square the dishwasher in the cutout When attaching the anti tip brackets make sure the tub and frame are not skewed so that the tub gasket contacts the door liner fully all the way aroun...

Страница 11: ...inet panel and using padded clamps clamp the cabinet panel to the dishwasher front Slowly lower the door and panel to it s full open position Attach it to the dishwasher door front utilizing the four...

Страница 12: ...ctly to the drain tee or disposal above the sink trap as shown below Tighten the holding clamp For installations with an air gap check to make sure the drain line from the air gap to the disposal drai...

Страница 13: ...fill with water Wait approximately two 2 minutes then carefully open the door to verify water is filling the dishwasher tank If there is water present close the door and continue the process Should t...

Страница 14: ...ligns with the adjacent cabinet toe kick Installing a Custom Toe Kick Model ID30 See the Custom Panel Installation Template Dacor PN 101394 for complete installation instructions of a custom toe kick...

Страница 15: ......

Страница 16: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: