12 English
Ins
tallation r
equir
ement
s
Installation requirements
13 in (33 cm)
Overhead
Cabinet Depth
0 in (0 cm)
24.2 in
(61.5 cm)
24 in
(61 cm) Lower
Cabinet Depth
4 in*
(10.2 cm)
6 in*
(15.2 cm)
36 in
(91.4 cm)
30 in
(76.2 cm)
18 in
(45.7 cm)
30 in (76.2 cm)
30 in (76.2 cm)
0 in (0 cm)
Clearance Below
Cooking Top
and at Rear and
Sides of Range
* Side clearance above cooking surface to any objects, i.e., wall.
CAUTION
DO NOT
install the oven so that the door is flush with the cabinet.
Installation requirements
Location requirements
Clearances and dimensions
NOTE
•
For OTR over Gas Stove, please follow local GAS CODE.
•
BEFORE YOU BEGIN
to install this appliance, refer to the following information,
dimensions, and clearances.
Do not locate the range where it may be subject
to strong drafts.
Provide adequate clearances between the range and adjacent
combustible surfaces. These dimensions must be met for safe use of the range.
The location of the electrical outlet and gas piping may be adjusted to meet
the following dimensions and clearances.
•
For installation in Canada, a free-standing range is not to be installed closer
than 4.7 in (12 cm) from any adjacent surface.
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops,
and cabinets around the range can withstand the heat (up to 194 °F [90 °C])
generated by the range. If not, discoloration, delamination, or melting may occur.
INSTALL_DOP30T840GS_DA_DG68-01456A-00_EN.indd 12
INSTALL_DOP30T840GS_DA_DG68-01456A-00_EN.indd 12
2022-10-06 오후 6:51:56
2022-10-06 오후 6:51:56