background image

17

Installation Instructions

Verifying Proper Operation

1.  Remove any packaging from inside the oven.
2.  Slide the oven racks onto the supports inside the oven 

chamber(s) according to the use and care manual.

3.  Prior to operating the range, please read the accompanying 

use and care manual carefully. Important safety, service and 

warranty information are contained within.

4.  Turn on the power supply to the range.
5.  Set the clock according to the use and care manual.
6.  Press the 

BAKE

 key on the control panel. The default bake 

temperature should appear on the display.

7.  Press 

START

. After approximately three (3) minutes, check to 

make sure the oven is heating.

8.  Turn each of the knobs on the front counter-clockwise to the 

HI position, in turn. Make sure each element begins to heat. 

On the dual and triple elements, make sure all the elements 

are working. The residual heat indicator lights for each 

element should come on when each element is on.

9.  If either the oven or cooktop does not operate properly, follow 

these troubleshooting steps:

◊ 

Verify that power is being supplied to the range.

◊ 

Check the electrical connections to ensure that the 

installation has been completed correctly.

◊ 

Repeat the above tests.

◊ 

If the appliance still does not work, contact Dacor 

Distinctive Service at (800) 793-0093, extension 2822. 

Do not attempt to repair the appliance yourself. If you 

need service, be sure to have the model and serial 

numbers available when you call. See the inside cover 

for location.

Dacor is not responsible for the cost of correcting problems 

caused by a faulty installation.

Installation Checklist

 

wARNINg

To ensure a safe and proper installation, the installer must 

perform the following checklist to ensure that no part of the 

installation has been overlooked. Proper installation is the 

responsibility of the homeowner.

1.  Has the plastic coating been peeled off of the outside of the 

range? Have all packaging materials been removed from 

inside the oven?

2.  Are all of the legs extended down to make contact with the 

floor? Is the unit level? See page 16.

3.  Is the range secured in place with the provided anti-tip 

bracket according to these instructions? See page 8 and 

16.

4.  Is the range wired and grounded according to these 

instructions and in accordance with all applicable electrical 

codes? Has the electrical access cover been replaced? See 

pages 3 and 10.

5.  Is the oven door properly installed according to these 

instructions? See page 16.

6.  Has proper operation been verified?
7.  Has the warranty been activated on-line or the warranty card 

been filled out completely and mailed?

A

A

C

B

L O

H I

L O

H I

SINGLE

L O

H I

DUAL

L O

H I

L O

H I

L O

H I

SINGLE

DUAL

TRIPLE

Single element ON

Inner element ON

Inner element ON

Both elements ON

All elements ON

Inner and middle 

elements ON

Single Circuit Elements

A

Dual Circuit Element

B

Triple Circuit Element

C

Содержание Distinctive DR30E

Страница 1: ...Installation Instructions Distinctive Electric Range Part No 105906 Rev B Models DR30ES DR30EIS DR30EFS and DR30EIFS...

Страница 2: ...16 Re installing the Oven Door 16 Verifying Proper Operation 17 Customer Service Information If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Daco...

Страница 3: ...ages in the oven bottom or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause a fire hazard Aluminum foil linings may also trap heat caus...

Страница 4: ...owner is responsible to make sure this appliance is properly installed This appliance must not be used in combination with surface countertop ventilation systems The use of an overhead hood or Dacor r...

Страница 5: ...talled by a licensed electrician The appliance may be connected one of the following ways Using conduit A 4 wire conduit connected to a 4 wire junction box or A 3 wire conduit where local code permits...

Страница 6: ...lat stainless trim piece in place of a backguard A backguard may be purchased as an optional accessory Add an additional 1 16 inch to depth dimensions above when installing a backguard on models DR30E...

Страница 7: ...is to be provided directly above the range the risk of personal injury may be reduced by installing a range hood The range may be installed flush to the rear wall Dacor recommends installing a non com...

Страница 8: ...ountertop front Top View Slide In Self Rimming Installation 3 Side Panels Installed Top View Slide In Self Rimming Installation 3 Side Panels Removed Self Rimming Installation Cutout Options Models DR...

Страница 9: ...les above counter both sides 22 3 4 57 8 cm 2 5 8 6 7 cm 24 3 8 61 9 cm max Countertop front Self Rimming Installation with Raised Vent Cutout Options Models DR30EIS and DR30EIFS Only Countertop heigh...

Страница 10: ...quired The minimum full thread depth portion of screw threaded into wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See the table below to select the correct screw size Sub Floor Type Floor...

Страница 11: ...thod may not be used and the floor mounting method must be suitable or the wall must be modified so that the base plate is above the notches 4 To install the bracket place it against the wall in the m...

Страница 12: ...ance Dacor is not responsible for damages resulting from improper installation This range must be connected to a grounded metallic permanent wiring system Alternatively a grounding conductor should be...

Страница 13: ...in relief inside the box Tighten into place 6 Connect the white wire to the neutral terminal in the box 7 Connect the black wire to the L1 power supply terminal 8 Connect the red wire to the L2 power...

Страница 14: ...appliance to the junction box 2 Connect the white wire from the appliance to the neutral white supply wire in the junction box 3 Connect the black wire from the appliance to the black L1 power supply...

Страница 15: ...Conduit Junction Box Connection with External Ground Separate No 10 minimum copper grounding wire Wire nut 4 places Conduit to appliance Conduit to appliance Wire nut 3 places Junction box Junction b...

Страница 16: ...Do not connect the green appliance wire to the neutral white supply wire unless local building codes permit 1 Remove the range electrical access cover from the back of the range 2 If using a 4 wire c...

Страница 17: ...umper link Link removed Ground screw L2 terminal L2 terminal L1 wire L1 wire White wire White wire Green wire L2 wire L2 wire Strain relief Strain relief 3 Wire Appliance Cord Connection Where Local C...

Страница 18: ...loor to the countertop and adjust the leveling legs as required to position the top frame at the desired height based on the cabinet and countertop installation 2 Carefully slide the range into positi...

Страница 19: ...repair the appliance yourself If you need service be sure to have the model and serial numbers available when you call See the inside cover for location Dacor is not responsible for the cost of corre...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: