8

Installing the Duct Work

IMPORTANT - The installed duct work must:

•  Be centered on the vertical center line drawn on the 

• wall.

•  Fit flush into the half circle on the chimney mount-

ing • bracket, if the duct work is to enter the chimney 

through the ceiling rather than through the back wall).

•  Extend down as far as the top of the blower assem-

bly mounting bracket.

If mounting the hood to brick or masonry:
•  Drill five 5/16” X 1 1/2” holes in the locations 

marked.

•  Insert five of the provided wall anchors into the 

five holes. The anchors provided are for attaching 

the hood to masonry or brick only.

6.  Attach the blower assembly mounting bracket and the 

“L” brackets securely to the wall (5 places).

Installation Instructions

Duct through ceiling 

(option 1)

Duct through back 

wall (option 2)

End of duct, even with 

top of blower assembly 

mounting bracket

"L" brackets

Duct Work Installation

Ceiling mounting 

bracket

Wall

"L" brackets

Template

Mounting to Brick or Masonry

Mounting 

bracket

Anchor

Содержание Discovery PHW Series

Страница 1: ...Installation Instructions Discovery GlassWall Mount Range Hood PHW Model Series Part No 101745 Rev H...

Страница 2: ...installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Hel...

Страница 3: ...G a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the serv...

Страница 4: ...rfaces often to prevent grease fires and maintain performance If the cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could...

Страница 5: ...ation Contact your local building department for further information The minimum installed distance from the rear of blower unit base to the cooktop surface must be no less than 30 inches 76 2 cm 26 i...

Страница 6: ...ceilings or into attics crawl spaces or garages To prevent combustion by products smoke or odors from entering the home and to improve efficiency tape all duct joints securely Do not exhaust more than...

Страница 7: ...Work Design Tips Wherever possible reduce the number of transitions and turns to as few sharp angles as possible Two staggered 45 angles are better than one 90 Keep turns as far away from the hood exh...

Страница 8: ...ure Replacement kit PN 101963 includes both chimney and blower mounting bracket Order the correct size see page 3 A A B C C B D D E F G G H H F E 8 20 cm WARNING Do not install the range hood unless t...

Страница 9: ...7 Insert the two of the provided wall anchors into the holes on the ceiling 8 Place the chimney mounting bracket against the ceil ing and attach it using two included 1 1 2 screws Installing the Blowe...

Страница 10: ...k or masonry Drill five 5 16 X 1 1 2 holes in the locations marked Insert five of the provided wall anchors into the five holes The anchors provided are for attaching the hood to masonry or brick only...

Страница 11: ...er flaps on the top of the hood from opening 1 Inside the exhaust outlet on the top of the blower assembly there are metal or plastic damper flaps The flaps close to help prevent back drafts when the...

Страница 12: ...fire hazard make sure the power supply at the fuse or junction box is turned off before proceeding with final installation Improper connection of the hood electrical wiring may create an electric shoc...

Страница 13: ...on the bottom of the blower assembly 4 Insert all four thumb screws into the bottom of the glass and tighten into place Installing the Chimney 5 Carefully put the chimney over the blower assembly taki...

Страница 14: ...d filled out completely and mailed Verifying Proper Operation 1 Turn on power at the junction or fuse box 2 If the control panel is not lit turn on the main power switch located next to the light fixt...

Страница 15: ......

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: