background image

12

Replacement Parts List

Replacement parts can be obtained by contacting 

 

Dacor Customer Service.

Dacor Customer Assurance

Phone: 833-35-ELITE (833-353-5483) USA, Canada)

Mon – Fri 5:00 

a

.

m

.

 to 5:00 

p

.

m

.

 Pacific Time

Model DYCT3xxG/HPCT3xxG Cooktop Parts

 See 

Burner Parts

 and 

Cooktop Layout

 (next page)

Cooktop Part

DYCT304G,

HPCT304G

DYCT365G,

HPCT365G

Hold-Down Bracket 

w/screws (set of 2)

PN 12269

PN 12269

Regulator (Natural Gas models)

PN 62834

PN 62834

Regulator (LP Gas models)

PN 72980

PN 72980

Knobs

PN 109321

PN 109321

Trim Rings: Single LR (left rear)

PN 108924-03

--

Trim Rings: Single RF, RR (right 

front, right rear)

PN 108924-02

--

Trim Rings: SimmerSear™ 

LF (left front)

PN 108925-02

--

Trim Rings: Single RR, CR, LR 

(right rear, center rear, left rear)

--

PN 108924-01

Trim Rings: SimmerSear™ LF, 

CF (left front, center front)

--

PN 108925-01

Grate: large

PN 108900

PN 108900

Grate: small

--

PN 108901

Grate support feet (4)

PN 103712

PN 103712

Stainless steel 

cleaner

PN A302

PN A302

Model DYCT365G/HPCT365G

See 

Burner Parts

 and 

Cooktop Layout

 (next page)

Burner Part

Dacor P/N

Cap Cover: LF (left front)

92232

Burner Cap: LF (left front)

92230

Burner Skirt: LF (left front)

92226

Cap Cover: LR, RR (left rear, right rear)

92235

Burner Head: LR, RR (left rear, right rear)

103735

Cap Cover: CF (center front)

92231

Burner Cap: CF (center front)

92460

Burner Skirt: CF (center front)

92459

Cap Cover: CR (center rear)

92236

Burner Head: CR (center rear)

103737

Model DYCT304G/HPCT304G

See 

Burner Parts

 and 

Cooktop Layout

 (next page)

Burner Part

Dacor P/N

Cap Cover: LF (left front)

92231

Burner Cap: LF (left front)

92460

Burner Skirt: LF (left front)

92459

Cap Cover: LR, RF (left rear, right front)

92235

Burner Head: LR, RF (left rear, right front)

103735

Cap Cover: RR (right rear)

92236

Burner Head: RR (right rear)

103737

Replacement Parts List

Large:

Small:

Grate Sizes

Models

Models

DYCT304G, DYCT365G,

HPCT304G, HPCT365G

DYCT365G, HPCT365G

Содержание Discovery HPCT304G

Страница 1: ...Installation Instructions Discovery Gas Cooktop Models DYCT304G DYCT365G HPCT304G HPCT365G Part No 108861 Rev B ...

Страница 2: ...e consumer Write the Product Data Label information inside the Use and Care manual for the consumer s future reference Consumer Keep these Installation Instructions for future reference and for the local electrical inspector s use Note Dacor is not responsible for service required to correct a faulty installation 2018 Dacor all rights reserved If You Need Help If you have questions or installation...

Страница 3: ...appliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s instructions If you cannot contact the gas supplier call the fire department DANGER IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline on or in the v...

Страница 4: ... of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock or serious injury or death when using your appliance follow basic safety precautions including the following Do not leave the cooktop unattended while in use to avoid the possibility of a fire Do not leave children alone or unattended in the area around the cooktop Do not allow children to play with the ...

Страница 5: ...Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Units equipped for LP operation have LP in the model number listed on the product data label See the Product Data Label section for label location Check your local building codes for the proper method of installation In the absence of local codes this appliance should be installed i...

Страница 6: ...rface Bottom of spill tray to 19 1 2 49 5 cm 4 10 2 cm 13 16 2 1 cm 3 3 4 9 5 cm Gas inlet Power cord Chassis Front of cooktop Top panel overhang 2 1 8 5 4 cm 5 8 1 6 cm DYCT304G HPCT304G PowerCord and Gas Inlet Location Model DYCT304G HPCT304G WARNING Observe all governing codes and ordinances during planning and installation Contact your local building department for further information Product ...

Страница 7: ...of cooktop Top panel overhang 2 1 4 5 7 cm DYCT365G HPCT365G PowerCord and Gas Inlet Location 36 76 2 cm 21 53 3 cm 4 10 2 cm Chassis height 19 1 2 49 5 cm 33 5 8 85 4 cm Including raised embosses on sides of chassis 2 1 8 5 4 cm top of cooking surface Bottom of spill tray to Model DYCT365G HPCT365G ...

Страница 8: ...en the unit is installed The 40 inch 101 6 cm power cord must be able to reach an electrical outlet and that electrical outlet must be easily accessible after the cooktop is installed Access to the underside of the cooktop for service and inspection purposes Clearance inside the counter to allow for correct instal lation of the hold down brackets To allow underneath access to the utilities and coo...

Страница 9: ...tolerances 1 16 0 1 6 mm unless otherwise noted Installation Type C Minimum D E F DYCT304G HPCT304G no downdraft 2 7 8 7 3 cm 19 3 4 50 2 cm 27 5 8 70 1 cm 7 1 2 19 1 cm DYCT304G HPCT304G with ERV3015 or PRV30 3 8 1 0 cm 22 1 2 57 2 cm DYCT304G HPCT304G with RV30 5 8 1 6 cm 22 1 4 56 5 cm DYCT365G HPCT365G no downdraft 2 7 8 7 3 cm 19 3 4 50 2 cm 33 3 4 85 7 cm 7 17 8 cm DYCT365G HPCT365G with ERV...

Страница 10: ...ly excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Before use test the gas lines for leaks as instructed Do not use a flame to check for leaks The maximum gas supply pressure to the regulator must never exceed 1 2 pounds per square inch psi or 3 5 kPa The cooktop and shut off valve must be disconnected from ...

Страница 11: ...it drops completely into place The burners will not function properly unless all of the burner pieces are correctly seated 3 Gently set the grates on top of the spill tray Make sure that the rubber feet are placed in the indentations located in the spill tray The SimmerSear burner head is permanently attached to the burner base It cannot be removed by the user Burner and Grate Diagram for DYCT304G...

Страница 12: ...he flame height SimmerSear burners turn the control knob to the simmer setting and make sure the low level flame can be adjusted When the unit is installed correctly the flame will burn steadily It will have a sharp blue inner cone that will vary in length proportional to the burner size The flame will be reduced by the Smart Flame feature under the grate fingers to increase the life of the grate ...

Страница 13: ...ice for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 3 Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions See page 3 Is the cooktop secured using the provided hold down brackets See page 8 Is the cooktop connected to the gas supply according to these in...

Страница 14: ... 108900 PN 108900 Grate small PN 108901 Grate support feet 4 PN 103712 PN 103712 Stainless steel cleaner PN A302 PN A302 Model DYCT365G HPCT365G See Burner Parts and Cooktop Layout next page Burner Part Dacor P N Cap Cover LF left front 92232 Burner Cap LF left front 92230 Burner Skirt LF left front 92226 Cap Cover LR RR left rear right rear 92235 Burner Head LR RR left rear right rear 103735 Cap ...

Страница 15: ...he igniter Feet bottom view Cap cover Cap cover Burner base DYCT304G HPCT304G Replacement Parts List Cooktop Layout Left Rear Right Rear Center Rear Left Front Right Front Center Front Burner Location LR RR CR LF RF CF DYCT365G HPCT365G Trim ring Spill tray Grate SimmerSear control knobs LR CR RR LF CF Burner control knob Trim ring Grate Spill tray LR RR LF RF Trim ring SimmerSear control knob Bur...

Страница 16: ...SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPER AND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WIRING DIAGRAM DYCT304G DYCT304G HPCT304G ...

Страница 17: ...TOR LED RR BK INDICATOR LED CR BK INDICATOR LED LR ISOLATOR BOARD P N 106104 L1 IGNITOR LR BURNER W N RE IGNITOR RED NO SWITCH S1 BK BK BK W RE IGNITOR IGNITOR CR BURNER N S2 BK NO SWITCH L1 RED W BK RE IGNITOR IGNITOR RR BURNER N S3 BK NO SWITCH L1 RED W BK L1 NO SWITCH N NEON SIMMER INDICATOR LIGHT BK IGNITOR LF BURNER W IGNITOR CF BURNER S5 BK BK RE IGNITOR RED BK BK RE IGNITOR BK S4 L1 W S4 RE...

Страница 18: ...Notes ...

Страница 19: ...Notes ...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Отзывы: