background image

8

Verifying the Package Contents

•  Hold-down brackets (2)
•  Grates: DYCT304G (2), DYCT365G (3)
•  Burner sets: DYCT304G (4), DYCT365G (5)
•  Gas pressure regulator (1)
•  Stainless steel cleaner (1)    

 

 

(stainless steel models only)

If any parts are missing, see the 

Replacement Parts List

 

section on page 12 for Dacor Customer Service and 

ordering information.

Installing the Cooktop

 WARNING

•  Verify that the power supply meets the specifications 

on page 3 before proceeding.

•  To prevent damage to the gas pressure regulator, 

install it only after the cooktop is mounted in its per-

manent position.

 IMPORTANT

•  Do not over-tighten the hold-down bolts. Over tight-

ening the hold down bolts may result in improper 

operation of the dual gas burners.

•  Do not use a hardening compound or caulk to perma-

nently seal the cooktop into place. The cooktop must 

be readily removable if service is required. Removal 

of sealant to service the unit will be performed at the 

customer’s expense.

1.  If the cooktop will be used with a downdraft, first install 

the downdraft according to the downdraft installation 

instructions.

2.  Lower the cooktop into the cutout and center it. 
3.  Secure the cooktop to the countertop using the two (2) 

hold-down brackets as shown (included).

Installation Instructions

Connecting the Gas Line

 WARNING

•  Verify that the gas supply meets specifications before 

connection. See page 3.

•  Do not install or use the cooktop without the included 

gas regulator installed.

•  Ensure that the arrow on the regulator points in the 

direction of the gas flow, toward the cooktop.

•  Do not apply excessive pressure when tightening gas 

connections and fittings.

•  Do not use Teflon tape or plumber’s putty on flexible 

gas line connections.

•  Before use, test the gas lines for leaks as instructed. 

Do not use a flame to check for leaks. 

•  The maximum gas supply pressure to the regulator 

must never exceed 1/2 pounds per square inch (psi) 

or 3.5 kPa.

•  The cooktop and shut-off valve must be disconnected 

from the gas supply piping system during any pres-

sure testing exceeding 1/2 psi (3.5 kPa).

•  The cooktop must be isolated from the gas supply 

piping system by closing the shut-off valve to the 

cooktop during any gas supply piping system pres-

sure testing equal to or less than 1/2 psi (3.5 kPa).

•  For LP gas installations, the LP gas tank must have 

its own high-pressure regulator in addition to the 

pressure regulator supplied with the cooktop.

Refer to the figure 

Underneath the Cooktop 

on the left 

while following these gas hookup instructions.
1.  Attach the gas pressure regulator (included) to the gas 

inlet on the cooktop. 

•  When working in tight space constraints, the regulator 

can be installed anywhere between the cooktop and 

gas supply/shut-off valve.

•  For best performance, attach the regulator as close as 

possible to the cooktop. This will minimize gas pressure 

loss.

2.  Connect regulator to the gas supply/shut-off valve with 

a minimum 1/2” flexible gas line (not included). 

3.  Check for gas leaks:

◊ 

Turn all 

cooktop

 control valves to OFF.

◊ 

Make a soap and water solution or use a gas leak 

detector and check all lines and connections for 

gas 

leaks. 

 

 

     

* Make sure the gas supply/shut-off valve is ON.

◊ 

Turn the gas supply/shut-off valve OFF.

Hold-down bracket 

mounting holes

(both sides)

Gas inlet

Power cord

Below the Cooktop

Model DYCT365G/

HPCT365G shown

Содержание Discovery HPCT304G

Страница 1: ...Installation Instructions Discovery Gas Cooktop Models DYCT304G DYCT365G HPCT304G HPCT365G Part No 108861 Rev B ...

Страница 2: ...e consumer Write the Product Data Label information inside the Use and Care manual for the consumer s future reference Consumer Keep these Installation Instructions for future reference and for the local electrical inspector s use Note Dacor is not responsible for service required to correct a faulty installation 2018 Dacor all rights reserved If You Need Help If you have questions or installation...

Страница 3: ...appliance Do not touch any electrical switch or use any electri cal devices including the telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s instructions If you cannot contact the gas supplier call the fire department DANGER IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline on or in the v...

Страница 4: ... of the appliance WARNING General Safety Precautions To reduce the risk of fire electric shock or serious injury or death when using your appliance follow basic safety precautions including the following Do not leave the cooktop unattended while in use to avoid the possibility of a fire Do not leave children alone or unattended in the area around the cooktop Do not allow children to play with the ...

Страница 5: ...Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Units equipped for LP operation have LP in the model number listed on the product data label See the Product Data Label section for label location Check your local building codes for the proper method of installation In the absence of local codes this appliance should be installed i...

Страница 6: ...rface Bottom of spill tray to 19 1 2 49 5 cm 4 10 2 cm 13 16 2 1 cm 3 3 4 9 5 cm Gas inlet Power cord Chassis Front of cooktop Top panel overhang 2 1 8 5 4 cm 5 8 1 6 cm DYCT304G HPCT304G PowerCord and Gas Inlet Location Model DYCT304G HPCT304G WARNING Observe all governing codes and ordinances during planning and installation Contact your local building department for further information Product ...

Страница 7: ...of cooktop Top panel overhang 2 1 4 5 7 cm DYCT365G HPCT365G PowerCord and Gas Inlet Location 36 76 2 cm 21 53 3 cm 4 10 2 cm Chassis height 19 1 2 49 5 cm 33 5 8 85 4 cm Including raised embosses on sides of chassis 2 1 8 5 4 cm top of cooking surface Bottom of spill tray to Model DYCT365G HPCT365G ...

Страница 8: ...en the unit is installed The 40 inch 101 6 cm power cord must be able to reach an electrical outlet and that electrical outlet must be easily accessible after the cooktop is installed Access to the underside of the cooktop for service and inspection purposes Clearance inside the counter to allow for correct instal lation of the hold down brackets To allow underneath access to the utilities and coo...

Страница 9: ...tolerances 1 16 0 1 6 mm unless otherwise noted Installation Type C Minimum D E F DYCT304G HPCT304G no downdraft 2 7 8 7 3 cm 19 3 4 50 2 cm 27 5 8 70 1 cm 7 1 2 19 1 cm DYCT304G HPCT304G with ERV3015 or PRV30 3 8 1 0 cm 22 1 2 57 2 cm DYCT304G HPCT304G with RV30 5 8 1 6 cm 22 1 4 56 5 cm DYCT365G HPCT365G no downdraft 2 7 8 7 3 cm 19 3 4 50 2 cm 33 3 4 85 7 cm 7 17 8 cm DYCT365G HPCT365G with ERV...

Страница 10: ...ly excessive pressure when tightening gas connections and fittings Do not use Teflon tape or plumber s putty on flexible gas line connections Before use test the gas lines for leaks as instructed Do not use a flame to check for leaks The maximum gas supply pressure to the regulator must never exceed 1 2 pounds per square inch psi or 3 5 kPa The cooktop and shut off valve must be disconnected from ...

Страница 11: ...it drops completely into place The burners will not function properly unless all of the burner pieces are correctly seated 3 Gently set the grates on top of the spill tray Make sure that the rubber feet are placed in the indentations located in the spill tray The SimmerSear burner head is permanently attached to the burner base It cannot be removed by the user Burner and Grate Diagram for DYCT304G...

Страница 12: ...he flame height SimmerSear burners turn the control knob to the simmer setting and make sure the low level flame can be adjusted When the unit is installed correctly the flame will burn steadily It will have a sharp blue inner cone that will vary in length proportional to the burner size The flame will be reduced by the Smart Flame feature under the grate fingers to increase the life of the grate ...

Страница 13: ...ice for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 3 Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions See page 3 Is the cooktop secured using the provided hold down brackets See page 8 Is the cooktop connected to the gas supply according to these in...

Страница 14: ... 108900 PN 108900 Grate small PN 108901 Grate support feet 4 PN 103712 PN 103712 Stainless steel cleaner PN A302 PN A302 Model DYCT365G HPCT365G See Burner Parts and Cooktop Layout next page Burner Part Dacor P N Cap Cover LF left front 92232 Burner Cap LF left front 92230 Burner Skirt LF left front 92226 Cap Cover LR RR left rear right rear 92235 Burner Head LR RR left rear right rear 103735 Cap ...

Страница 15: ...he igniter Feet bottom view Cap cover Cap cover Burner base DYCT304G HPCT304G Replacement Parts List Cooktop Layout Left Rear Right Rear Center Rear Left Front Right Front Center Front Burner Location LR RR CR LF RF CF DYCT365G HPCT365G Trim ring Spill tray Grate SimmerSear control knobs LR CR RR LF CF Burner control knob Trim ring Grate Spill tray LR RR LF RF Trim ring SimmerSear control knob Bur...

Страница 16: ...SERVICING VERIFY PROPER OPERATION 120V 60Hz POWER SUPPLY CAUSE IMPROPER AND DANGEROUS OPERATION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WIRING DIAGRAM DYCT304G DYCT304G HPCT304G ...

Страница 17: ...TOR LED RR BK INDICATOR LED CR BK INDICATOR LED LR ISOLATOR BOARD P N 106104 L1 IGNITOR LR BURNER W N RE IGNITOR RED NO SWITCH S1 BK BK BK W RE IGNITOR IGNITOR CR BURNER N S2 BK NO SWITCH L1 RED W BK RE IGNITOR IGNITOR RR BURNER N S3 BK NO SWITCH L1 RED W BK L1 NO SWITCH N NEON SIMMER INDICATOR LIGHT BK IGNITOR LF BURNER W IGNITOR CF BURNER S5 BK BK RE IGNITOR RED BK BK RE IGNITOR BK S4 L1 W S4 RE...

Страница 18: ...Notes ...

Страница 19: ...Notes ...

Страница 20: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Отзывы: