Center Spray Arm and Upper Rack Manifold
Remove upper rack and place rack upside down on a flat surface.
Place blade of a very thin putty knife between retaining ring and center spray arm. Lightly twist
knife to lift arm from retaining ring. (See Figure 30)
Remove manifold from rack by compressing tube retainer clips and sliding tube backwards to clear
front mount. Reverse this procedure to reattach manifold.
To reinstall arm, place both halves of retaining ring onto manifold. Place center spray arm over
retaining clips and press into place.
After replacing rack in tub, reinstall rail end caps.
Main Delivery Tube
To gain access to main delivery tube, cabinet will need to be removed. See section on
CABINET
REMOVAL
for detailed instructions.
Place dishwasher on its back. Loosen and remove clamp-holding tube from inline heater.
Set dishwasher upright to remove nozzle from rear inside of tub. This unscrews counterclockwise.
Remove tube from tub.
Reverse procedure to reinstall. Be sure to check gasket on upper end of tube before tube end is
placed into tub.