10. Trouble shooting and correction

   

problem

 

cause

 

correction

 

Display 

drifts 

* Defective Sensor 
* AC noise in power line 
* Defective connection 
to sensor (Noise) 
* Input filter set incorrectly 

* Check sensor state and output 
* Check power line and connection 
* Check connection to sensor 
* Check filter DIP switch   
* 6-2) check display time 
* 6-3) Change to AV mode 

Display 

19999 only 

* Discordance between   
   sensor output and DIP 
   S/W   setting 
* Open and short of 
   sensor in/output line 

* Check DIP switch about   
sensor output 
* Check sensor wiring 

Display 

change -- 

* Exchange of sensor 
   input line. 
* data setting error 

* Check sensor connection. 
* refer to 6-3) 

Not able to 

select 

FS,DP,CAL 

* Data Protection 

* Turn off data protection 
   refer to 3- 4) 

Analog output 
Problem 

* Defective voltage and current 

signal 

* Difficulty of setting 

* When 0

5V output is 

   required. 

* Check DIP Switch 5 
* Adjust zero and span VR 
      refer to 2-3) 
* Connect 1/4W 500

   

accuracy resistor between 
GND and OUT port 
* Contact the manufacturer. 

Other noise 
protection 

  

* Connection noise filter with 
AC input line 
* Set noise filter to coil in parallel   
* Check the shield. 

* If you have any questions, please contact the manufacturer. 

 

Содержание SM110

Страница 1: ...LTD http www dacell com TEL 82 43 2602242 FAX 82 43 2602245 1 DIGITAL INDICATOR SM110 150 INSTRUCTION MANUAL DACELL CO LTD TEL 82 43 260 2242 FAX 82 43 260 2242 WEBSITE http www dacell com EMAIL info...

Страница 2: ...ricity DACELL is not liability for mistake to use that change a property voluntarily change design adjustment voluntarily user carelessness cause defect 1 Installation 1 Product Spec Spec 96 48 3 78 1...

Страница 3: ...on mode 3 ANALOG OUTPUT 4 GND 5 Analog output is as following voltage or current DIP switch 5 on voltage output DIP switch 5 off current output ON Voltage Output 0 5V 1 5V 0 10V 2 10V OFF Current Outp...

Страница 4: ...ed on only one in accordance with kind of sensor Under 0 700mV V or over 3 500mV V are option SOFTWARE setting In cal mode input as follows according to sensor output 5 RELAY OUTPUT A NO and B NC cont...

Страница 5: ...Display operation mode of high relay HI setting Confirm and adjust high data operation Display operation mode of low relay LO setting Confirm and adjust low data FS setting Confirm and adjust full sca...

Страница 6: ...2 3 4 5 6 7 8 9 0 Input 8 Input data After setting up must press key therefore become input Auto zero 9 Sensor No load state 0V 4 10 Display 0 4 PROTECTION mode Use this mode for protection and secur...

Страница 7: ...AUTO CALIBRATION mode Convenience to use when do not know calibration data of sensor or displayed the measurement value differently 1 Adjust zero point of indicator 2 Apply known load to sensor Large...

Страница 8: ...calibration Check function Relay output analog output reset hold peak Press key data protection mode 5 HARDWARE 1 Selection of AC input power 1 Separate P C B from case 2 The following label is exist...

Страница 9: ...calibration execution 1 mV V range 0 700 1 249 mV V 1 5 mV V range 1 250 1 749 mV V 2 mV V range 1 750 2 499 mV V 3 mV V range 2 500 3 500 mV V 2 Adjustment of display time and measurement data unit 1...

Страница 10: ...y x 1 x x display to signal and display indicate opposite ex 20mA display 760 0 x x 0 x standard type Display 0 trace minute signal to 0 Tracking mode of zero point x x 1 x Display 0 display minute si...

Страница 11: ...ct relay response Max 66 sec nonlinear characteristics 0 02 F S temperature coefficient 0 02 F S display size 14 8 sampling time 15 times sec 30 times sec filter frequency 1 10 100 4 short protection...

Страница 12: ...rt of sensor in output line Check DIP switch about sensor output Check sensor wiring Display change Exchange of sensor input line data setting error Check sensor connection refer to 6 3 Not able to se...

Отзывы: