27
F-30. DAC mode (Setting Analog output type)
①
DN-10W, DN-25W, DN-27W, DN-50W, DN-70,80
(Standard setup value : b_10V)
Display data
Setting
b_05v
-5 ~ +5V output
bidirectional, polarity
b_10v
-10 ~ +10V output
b_02A
0 ~ 20mA output
unidirectional, unipolar
b_42A
4 ~ 20mA output
U_05v
0 ~ 5V output
bidirectional,
unipolar
U_10v
0 ~ 10V output
U_02A
0 ~ 20mA output
U_42A
4 ~ 20mA output
②
DN-20W, DN-30W
(Standard setup value : b_10V)
Display data
Setting
b_05v
0 ~ 5V
출력
unidirectional, unipolar
b_10v
0 ~ 10V
출력
b_02A
0 ~ 20mA
출력
b_42A
4 ~ 20mA
출력
U_05v
0 ~ 5V
출력
bidirectional,
unipolar
U_10v
0 ~ 10V
출력
U_02A
0 ~ 20mA
출력
U_42A
4 ~ 20mA
출력
F-31. DAC capacity (Analog Outupt value setup)
(Standard setup value : 30000)
Display data
Setting
0
Set the rated capacity of the Analog output
< If Setting value 10000>
Display
data
F-30
setting data
b_05v b_10v b_02A b_42A U_05v U_10v U_02A
U_42A
-10000
-5V
-10V
0
4mA
0
0
0
4mA
0
0
0
0
4mA
2.5V
5V
10mA
12mA
10000
+5V
+10V
20mA
20mA
5V
10V
20mA
20mA
~
+99999
Note) Models DN-20W and DN-30W cannot be negative (-) output.
Содержание DN-10W
Страница 12: ...11 6 Wiring Diagram DN 10W DN 50W DN 20W ...
Страница 13: ...12 DN 25W DN 27W DN 30W ...
Страница 14: ...13 DN 70 DN 80 Example External Input PLC Connection ...
Страница 17: ...16 ...