10
16 VOLTS AC
EARTH to green wire
220 VOLTS AC From mains supply
ELECTRICAL WIRING (SOLO AND CONDO )
•
The transformer must be plugged into a normal plug socket in the house. 16 Volts AC is then run directly
to the P.C.Board 16 Volts AC connection. The distance between the transformer and the motor should
not exceed 50 meters.
•
Take care that the wires are connected the correct way. AC TO AC and EARTH TO EARTH
•
The cable should be run in a 300 mm deep trench in a water proof conduit and must be terminated
inside the motor
.
•
There must be no joins in the cable underground.
•
The cable should be a three core 1.5mm cable. Do not use communication cable as this will void
any warranty
NOTE the transformer must not be opened in any way as this may cause electrical shock
Connect from the transformer 16volts AC to the 16v AC on the main P.C. board.
Connect from the ETH (earth) on the transformer to the GREEN wire on the main P.C.Board
WIRING DIAGRAM FROM TRANSFORMER TO CHARGER (SOLO AND CONDO)
The following section explains how the wiring should be done for the CONDO and SOLO motors only.
For the wiring of the CONDO AC / DC motor see “AC / DC wiring” section.