![Dabos PG25CSH Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/dabos/pg25csh/pg25csh_instructions-for-installation-and-operation-manual_495567014.webp)
28
the burner will run at Level1 for the set time, and then will stop. If room
thermostat changes back to ON before time elapses, the burner will revert
to normal operation.
11. If burner is stopped due to room thermostat, and (Parameter#28-“
AMB_DELAY”) is not “0”, after room thermostat changes back to “ON”
the burner will wait this time to elapse before initiating new ignition
cycle. (The minimal temperature should be reached also)
Operating at Level 1
-Pellets feeding pause (Parameter#13-“Burn Auger Pause 1”)
-The fan works at defined speed (Parameter#17-“Burn Fan1”
Operating at Level 2
-Pellets feeding pause (Parameter#12-“Burn Auger Pause 2”)
-The fan works at defined speed (Parameter#16-“Burn Fan2”
Operating at Level 3
-Pellets feeding pause (Parameter#11-“Burn Auger Pause 3”)
-The fan works at defined speed (Parameter#15-“Burn Fan3”
Mode”Turn Off”-the inscription “Turn Off” is displayed
1.The fan is operating at 100%.
2. After the flame turns off, the countdown timer starts
(Parameter#18-“StopMax Time”.
3.
After the time elapses, the burner goes into mode "Ready" or "Off"
depending on the preset mode.
4. Activation of purging/cleaning mode for a preset time.
Mode”
Standby”-the inscription “Standby” is displayed
1.You should wait the temperature to fall below “Tmin” and the ignition
will start again.
Mode”Off”
1.
Wait timer turn off the device or press buttons on the controller.