28
Remove and clean the burner’s throat, remove and clean the burner and screw it
to the boiler again, every 24 or 48 hours.
Periodically check the flue of the boiler and if there is congestion it should be
cleaned.
Check the burner control with a gas analysis instrument once a year.
ATTENTION! ALL SERVICES ON THE ELECTRICAL SYSTEM AND THE
BURNER MUST BE DONE BY AN AUTHORISED MANUFACTURER’S
SERVICE.
POSSIBLE TROUBLESHOOTING
The device does not work:
- check if the pellets quantity is enough ;
- check if the auger transporter works (whether there is pellets feeding);
The device does not start
:
- check if the burner’s electrical supply is present;
- check the safety valve in the feeding module.
ATTENTION! SWITCH OFF THE POWER SUPPLY BEFORE
OPENING THE COVER! The check must be done by a qualified electrical
technician!
- check the voltage source, check for loose connections;
- check the boiler’s thermostat if a start signal does not come from the boiler;
- if a lamp ALARM lights, remove the reason for the disturbance
-check chimney if there is enough draught.
Unsuccessful ignition
-there is not enough initial quantity of pellets
-there is a problem with the igniter.
The fuel feeding is OK but there is no fire:
- check the ignition heater;
- check the voltage supply to the ignition heater.
The feeding and the ignition are both OK but the fan does not turn on:
- check the fan engine.
- check the ignition heater;
- check the voltage supply to the ignition heater.
Wrong parameter settings or parameters mismatch
-Recover the wrong parameters or perform factory reset