Degree of motor protection:
IP 44
Degree of terminal board protection:
IP 44
Protection class:
F
Environment temperature:
from -10 °C to +55 °C
Environment humidity:
≤
95%
Water temperature:
from 0 °C to +100 °C
Noise level:
For pumps intended for outdoor use: noise emission according to Directive
2000/14/CE.
For other pumps: noise emission according to Directive EC 89/392/CEE and
subsequent amendments.
Motor construction
in conformity with standards CEI 2-3 - CEI 61-69 (EN 60335-2-41)
5. MANAGEMENT
5.1 Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with
constant air humidity.
They are supplied in their original packaging and must remain there until the time of installation. If this is not
possible, the intake and delivery aperture must be accurately closed.
5.2 Transport
Avoid subjecting the products to needless jolts or collisions.
5.3 Weights
The adhesive label on the package indicates the total weight of the electropump.
6. WARNINGS
6.1 Skilled technical personnel
It is advisable that installation be carried out by skilled personnel in possession of
the technical qualifications required by the specific legislation in force.
The term
skilled personnel
means persons whose training, experience and instruction, as well as their
knowledge of the respective standards and requirements for accident prevention and working conditions,
have been approved by the person in charge of plant safety, authorizing them to perform all the necessary
activities, during which they are able to recognize and avoid all dangers.
(Definition for technical personnel IEC 364).
The appliance is not intended to be used by persons (including children) with reduced physical, sensory or
mental capacities, or who lack experience or knowledge, unless, through the mediation of a person
responsible for their safety, they have had the benefit of supervision or of instructions on the use of the
appliance. Children should be supervised to ensure that they do not play with the appliance
6.2 Safety
Use is allowed only if the electric system is in possession of safety precautions in accordance with the
regulations in force in the country where the product is installed (for Italy, CEI 64/2).
6.3 Responsibility
The Manufacturer does not vouch for correct operation of the pumps if they are
tampered with or modified, run outside the recommended work range or in contrast
with the other instructions given in this manual.
The Manufacturer declines all responsibility for possible errors in this instructions
manual, if due to misprints or errors in copying. The company reserves the right to
make any modifications to products that it may consider necessary or useful, without
affecting the essential characteristics.
Содержание K 40/22 HA
Страница 2: ...ITALIANO pag 1 FRAN AIS pag 11 ENGLISH pag 21 ESPA OL p g 31 PORTUGU S p g 41 51 61 Rte IZk...
Страница 56: ...54 7 7 1 K...
Страница 57: ...55 7 2 1 5 6 9 1 H 1 2 H 1 3 5 6 4 5 I MAN II AUT O STOP 100 C I MAN 8...
Страница 58: ...56 30 A I 30 A 14 4 65 9 10 0 C 11 I MAN II AUT O...
Страница 59: ...57 12 13 14 14 1...
Страница 60: ...58 14 2 220V PCB 3...
Страница 62: ...60 15 O I II 2 5 I 13 I II 0 13 16 Dab Pumps...
Страница 66: ...IZk 64 1 7 K...
Страница 70: ...IZk 68 2 14 220V PCB...
Страница 72: ...IZk 70 15 O I II 25 I 13 I II 0 13 16 Dab Pumps...
Страница 73: ......
Страница 74: ......
Страница 75: ......