ENGLISH
8
6. TROUBLESHOOTING
FAULTS
CHECKS (possible causes)
REMEDIES
1.
The system cuts out
abnormally.
–
The system has continued
pumping too long (thermal safety
switch).
–
Error in the control system.
–
Take the plug out of the
socket. Wait an hour and
reconnect the system.
Otherwise contact an
authorised customer service
centre.
2.
The system switches on
with interruptions.
–
The connected plumbing systems
are not sealed (valves, etc.).
–
The check valve is not closing
properly.
–
Check the system.
–
Clean or change the check
valve.
3.
The motor works
discontinuously and the
water is flowing very
slowly.
–
The ventilation hole in the cover
is blocked.
–
Clean the ventilation hole.
4.
The motor is working
correctly but it does not
switch off, remaining
operating for a long time.
–
Discharge too high or too long or
presence of too many bends in the
pipes with consequent loss of
pressure.
–
The bottom of the pump is
clogged.
–
Check the system.
Otherwise contact an
authorised customer service
centre.
5.
The motor does not start. –
The system is not connected to
the power mains.
–
The power socket is damaged.
–
There is a problem with the motor
or with the control system.
–
Connect the system to the
power mains.
Otherwise contact an
authorised customer service
centre.
6.
The motor is working
with a loud knocking
noise, or it is buzzing
and not working.
–
The motor is blocked by a foreign
body.
–
There is a problem with the motor
or with the control system.
–
Remove the foreign body.
Otherwise contact an
authorised customer service
centre.
7.
For FEKALIFT 200-A:
cloudy water returning
into the shower.
–
The shower is too low with
respect to the Fekalift system.
–
The check valves of the side
inlets are clogged.
–
Check the system installation.
–
Clean the check valves from
the outside, otherwise contact
an authorised customer
service centre
FEKALIFT 300-A LIFTING STATION
1.
TECHNICAL DATA AND LIMITATIONS OF USE
–
The FEKALIFT 300-A system is a small lifting station with extremely compact dimensions,
suitable
ONLY
for suspended toilets, to be installed behind ordinary wall modules, fig.A-B page 63
–
The system is used for the disposal of waste water from a toilet and possibly from other plumbing
equipment.
–
The system is
NOT
intended for use in public and/or commercial settings.
2. INSTALLATION
FEKALIFT 300-A is a built-in system. It may be fitted only and exclusively by a qualified, specialised
technician.
The small lifting station is equipped with retaining devices which prevent the unit becoming accidentally
detached from the toilet.
2.1 System
assembly
To assembly the Fekalift 300-A system follow see page 63
An inspection/maintenance hatch must be provided with ventilation slots in the frame