ENGLISH
GB
109
11.2.2. - Updating the e.sybox by e.sylink
An e.sybox can also be updated by e.sylink. For the procedure, refer to
the e.sylink manual.
12 - TROUBLESHOOTING
Before starting to look for faults it is necessary to disconnect the
power supply to the pump (take the plug out of the socket).
Solving typical problems
Fault
LED
Probable Causes
Remedies
The pump
does not
start.
Red: off
White: off
Blue: off
No electric power.
Check whether there is voltage
in the socket and insert the plug
again.
The pump
does not
start.
Red: on
White: on
Blue: off
Shaft blocked.
See paragraph 10.4 (motor shaft
maintenance).
The pump
does not
start.
Red: off
White: on
Blue: off
Utility at a level higher
than the system
restarting pressure
level (par. 3.2).
Increase the system restarting
pressure level by increasing SP or
decreasing RP.
The pump
does not
stop.
Red: off
White: on
Blue: off
1. Leak in the
system.
2. Impeller or hydrau
-
lic part clogged.
3. Air getting into the
suction pipe.
4. Faulty flow sensor
1. Check the system, find and
eliminate the leak.
2. Dismantle the system and
remove the obstructions (assis
-
tance service).
3. Check the suction pipe, find
and eliminate the cause of air
getting in.
4. Contact the assistance centre.
Insufficient
delivery
Red: off
White: on
Blue: off
1. Suction depth too
high.
2. Suction pipe
clogged or diame
-
ter insufficient.
3. Impeller or hydrau
-
lic part clogged.
1. As the suction depth increases
the hydraulic performance of
the product decreases (
De-
scription of the Electropump
).
Check whether the suction
depth can be reduced. Use
a suction pipe with a larger
diameter (but never smaller
than 1”).
2. Check the suction pipe, find the
cause of choking (obstruction,
dry bend, counterslope, …) and
remove it.
3. Dismantle the system and
remove the obstructions (assis
-
tance service).
The pump
starts with
-
out utility
request.
Red: off
White: on
Blue: off
1. Leak in the
system.
2.
Faulty non-return
valve.
1. Check the system, find and
eliminate the leak.
2. Service the non-return valve as
described in par. 10.3.
The water
pressure
when turn
-
ing on the
utility is not
immediate.
Red: off
White: on
Blue: off
Expansion vessel
empty (insufficient
air pressure) or has
broken diaphragm.
Check the air pressure through
the valve in the technical compart
-
ment. If water comes out when
checking, the vessel is broken:
assistance service. Otherwise
restore the air pressure according
to the equation par. 1.2.
Содержание E.sybox 30
Страница 6: ......
Страница 59: ...ITALIANO IT 56 ...
Страница 62: ......
Страница 116: ......
Страница 172: ......
Страница 228: ......
Страница 284: ......
Страница 340: ......
Страница 394: ......
Страница 448: ......
Страница 501: ...ROMÂNĂ RO 498 ...
Страница 504: ......
Страница 560: ......
Страница 616: ......
Страница 669: ...TÜRKÇE TR 666 ...
Страница 672: ......
Страница 728: ......
Страница 781: ...ČESKY CZ 778 ...
Страница 784: ......
Страница 838: ......
Страница 889: ......
Страница 906: ...903 فارسی ...