ENGLISH
GB
37
INDEX
Key
40
Warnings
40
Responsibility
41
1. General
41
1.1
Description of the Integrated Inverter
42
1.2
Integrated expansion vessel
42
1.3
Integrated electropump
43
1.4
Technical characteristics
44
2. Installation
44
2.1
Vertical Configuration
45
2.1.1
Hydraulic connections
45
2.1.2
Loading operation – Installation above head and below head
46
2.2
Horizontal Configuration
46
2.2.1
Hydraulic connections
47
2.2.2
Orientation of the interface panel
47
2.2.3
Loading operation – Installation above head and below head
48
3.
Commissioning
48
3.1
Electrical connections
48
3.2
Configuration of the integrated inverter
49
3.3
Priming
49
4.
The keypad and the display
50
4.1
Direct access with a combination of keys
51
4.2
Access by name with a drop-down menu
54
4.3
Structure of the menu pages
54
4.4
Blocking parameter setting by Password
55
4.5
Enabling and disabling the motor
55
5.
Meaning of the individual parameters
56
5.1
User Menu
56
5.1.1
Status
56
5.1.2
RS: Rotation speed display
56
5.1.3
VP: Pressure display
56
5.1.4
VF: Flow display
56
5.1.5
PO: Absorbed power display
56
5.1.6
C1: Phase current display
56
5.1.7 Operating hours and number of starts
56
5.1.8
PI: Power histogram
56
5.1.9 Output flow meter
56
5.1.10 VE: Version display
56
5.1.11 FF: Fault log display
57
5.2
Monitor Menu
57
5.2.1
CT: Display contrast
57
5.2.2
BK: Display brightness
57
5.2.3
TK: Backlight switch-on time
57
5.2.4
LA:
Language
57
5.2.5
TE: Dissipator temperature display
57
5.3
Setpoint Menu
57
5.3.1
SP: Setting the setpoint pressure
57
5.4
Manual Menu
58
5.4.1 Status
58
5.4.2 RI: Speed setting
58
5.4.3 VP: Pressure display
58
5.4.4 VF: Flow display
58
5.4.5 PO: Absorbed power display
58
5.4.6 C1: Phase current display
58
5.4.7 RS: Rotation speed display
58
5.4.8 TE: Dissipator temperature display
58
5.5
Installer Menu
58
5.5.1 RP: Setting the pressure fall to restart
59
5.5.2 OD: Type of plant
59
5.5.3 MS: Measuring system
59
5.5.4 EK: Setting the low pressure function on suction
59
5.5.5 PK: Low pressure threshold on suction
59
5.5.6 T1: Low pressure delay (function detecting low pressure on suction)
60
5.6
Technical Assistance Menu
60
5.6.1 TB: Water lack blockage time
60
5.6.2 T2: Delay in switching off
60
5.6.3 GP: Proportional gain coefficient
60
5.6.4 GI: Integral gain coefficient
60
5.6.5 RM: Maximum speed
60
5.6.6 AY: Anti Cycling
60
5.6.7 AE: Enabling the anti-block function
60
5.6.8 AF: Enabling the anti-freeze function
60
5.7 Setting low pressure detection on suction
61
5.8
RF:
Fault and warning reset
61
5.8.1
PW:
Change password
61
6.
Protection systems
61
6.1
Description of blockages
62
6.1.1
“BL”
Anti Dry-Run (Protection against dry running)
62
6.1.2
“
Anti-Cycling (Protection against continuous cycles without utility request)
62
6.1.3
“
Anti-Freeze (Protection against freezing of water in the system)
62
6.1.4
“BP1” Blockage due to fault of the delivery pressure sensor
63
6.1.5
“BP2” Blockage due to fault of the suction pressure sensor
63
6.1.6
“PB” Blockage due to supply voltage outside specifications
63
6.1.7
“SC” Blockage due to short circuit between the motor phases
63
Содержание DAB E.SYBOX
Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE...
Страница 2: ...Manual valid for firmware versions 4 x 1 x...