ENGLISH
105
The values 50 and 60 [Hz] have priority over other selections as they are the most common: on entry of any frequency value, when
the value 50 or 60 [Hz] is reached, the increment or decrement stops; to modify the frequency from one of these two values, release
each button and then press "+" or "-" for at least 3 seconds.
On initial start-up and when default settings are restored, FN is set at 50 [Hz] and the correct value must be entered, as
stated on the pump
.
Each modification to FN is interpreted as a system change, and therefore the parameters FS, FL and FP are adjusted automatically
according to the set FN. On each variation to FN re-check FS, FL, FP to ensure settings are as required.
6.5.4
OD: Type of system
Set with two possible values (1 and 2) according to a rigid or flexible system.
The inverter leaves the factory set to mode 1, suited to most systems. In the event of pressure variations that cannot be stabilised by
adjusting parameters GI and GP, switch to mode 2.
IMPORTANT:
In the two configurations, the values of adjustment parameters
GP
and
GI
also change. Furthermore, the values
of GP and GI set in mode 1 are stored in a different memory from the GP and GI values set in mode 2. Therefore,
for example, the value of GP in mode 1, when switching to mode 2, is replaced by the GP value of mode 2, but is
stored and restored on return to mode 1. The same value seen on display has a different meaning in each of the
modes, as the check algorithm is different.
6.5.5
RP: Setting the pressure drop for restart
This shows the drop in pressure, with respect to the value SP which causes pump restart.
For example, if the setpoint pressure is 3.0 [bar] and RP is 0.5 [bar] the pump is restarted at 2.5 [bar].
RP is normally set from a minimum of 0.1 to maximum 5 [bar]. In special conditions (for example in the case of a setpoint lower than
RP) this can be limited automatically.
To facilitate the work of the user, the RP setting page, highlighted below the symbol RP, shows the effective restart pressure; see
Figure 17.
Figure 19: Setting the restart pressure
6.5.6
AD: Address configuration
This is only applicable on multi-inverter systems. It sets the communication address to be assigned to the inverter. The possible values
are: automatic (default), or manually assigned address.
The manually assigned addresses can have values from 1 to 8. Configuration of the addresses must be uniform for all inverters in the
series: either all automatic or all manual. Identical addresses are not admitted.
If the address assignment modes are mixed (some manual and some automatic), and also if an address is duplicated, the relative
error is shown. The error is indicated with a flashing “E” in place of the unit address.
If selected assignment is automatic, each time the system is turned on, the addresses are assigned automatically and may be different
from the previous time; this has no effect on correct operation.
6.5.7
PR: Pressure sensor
Setting of the type of pressure sensor used. This parameter enables selection of a ratiometric or current type pressure sensor. For
each type of sensor, different full scales can be selected. When a ratiometric sensor is selected (default) the input Press 1 must be
used for connection. When a 4-20mA current sensor is used, the relative screw terminals on the input terminal board must be used.
(See Collegamento del sensore di pressione par 2.2.3.1)
Содержание AD 1.0 AC
Страница 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Страница 74: ...ENGLISH 72 Figure 2 Fixture and minimum clearance for air circulation...
Страница 135: ...FRAN AIS 133 Figure 2 Fixation et distance minimum pour la circulation de l air...
Страница 196: ...DEUTSCH 194 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Страница 257: ...ESPA OL 255 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Страница 269: ...ESPA OL 267 Figura 13 Ejemplo de conexi n de las entradas...
Страница 312: ...310 IEC 60634 1...
Страница 313: ...311 1 6 1 1...
Страница 317: ...315 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Страница 318: ...316 2...
Страница 319: ...317 2 2 3 3 15 2 2 1 1a 2a...
Страница 320: ...318 4a 5b 1b 127 240 240 480 3 6 3b...
Страница 324: ...322 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Страница 326: ...324 10 4 20 7 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 o OUT 7 J5 4 20 7 OUT 8 10 11 IN...
Страница 327: ...325 8 J5 1 7 J5 2 8 10 J5 9 11 4 20 PR 6 5 7 BP1 2 2 3 2 Flow 7 DIN 43650 6 0 5 DIN 43650 4 20 A A OUT B IN C D...
Страница 329: ...327 2 2 4 2 18 J5 1 I 1 16 17 I 2 15 16 I 3 13 14 I 4 12 13 50 60 7 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 9 11 8...
Страница 330: ...328 13 J5 I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 10...
Страница 331: ...329 11 I1 1 I2 3 I3 5 I4 10 I1 F1 I1 6 6 13 2 I2 P2 6 6 13 3 I3 F3 6 6 13 4 I4 1 F4 6 6 13 5 11 GND 7 I1 I2 I3 I4...
Страница 332: ...330 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Страница 333: ...331 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 12...
Страница 335: ...333 3 2 2 13 SET 15 15 14 16...
Страница 336: ...334 3 3 12 14 GO SB BL LP HP EC OC OF SC OT OB BP NC F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E0 E16 0 16 EE EEprom WARN...
Страница 337: ...335 17 15 15 3 4 PW 6 6 16 GO SB...
Страница 338: ...336 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Страница 341: ...339 I3 3 I4 4 OD PR PW 4 3 1 2 1 4 3 1 3 SET MODE LA RC MS FS SO AE O1 1 O2 2 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL...
Страница 346: ...344 6 6 1 MODE MODE 6 1 1 FR 6 1 2 VP 6 1 3 C1 A C1 RC 6 5 1 6 1 4 PO PO 6 1 5 SM 15 SB F 17 SM 15 F Sb RC A...
Страница 347: ...345 SM 6 1 6 VE 26 1 0 S 5 6 2 2 SET MODE 6 2 1 VF 6 2 2 TE 6 2 3 BT 6 2 4 FF FF x y x y x 1 x y 64 RF 6 2 5 CT 6 2 6 LA...
Страница 364: ...362 6 6 16 PW PW 0 PW 0 PW XXXX 10 PW 2 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...
Страница 367: ...365 OC 10 6 OF 10 6 33 8 8 1 PMW 4 2 8 2 8 3 8 3 SET EE EEprom FLASH...
Страница 379: ...NEDERLANDS 377 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Страница 440: ...SVENSKA 438 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Страница 501: ...T RK E 499 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Страница 556: ...554 IEC 364 1 inverter...
Страница 557: ...555 1 Inverter inverter inverter 6 inverter 1 1...
Страница 561: ...559 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Страница 562: ...560 2...
Страница 563: ...561 2 2 3 3 inverter 15 inverter 2 2 1 inverter inverter 1a 2a...
Страница 564: ...562 4a 5b 1b V 127 240 240 480 mm 3 6 3b azione...
Страница 568: ...566 2 2 2 inverter inverter GP GI 6 6 4 6 6 5 inverter 8 A B C D...
Страница 574: ...572 13 J5 pin Pin I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 10...
Страница 575: ...573 11 I1 1 I2 3 I3 5 I4 10 I1 F1 I1 6 6 13 2 I2 P2 6 6 13 3 I3 F3 6 6 13 4 I4 1 F4 6 6 13 5 11 V GND 7 1 2 3 4...
Страница 576: ...574 3 14 oled 64 X 128 4 MODE SET 12 inverter 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Страница 577: ...575 3 2 1 2 3 2 1 MODE SET Setpoint MODE 10 ONOMA TOY MENOY 2 Setpoint 2 5 5 5 2 2 12...
Страница 579: ...577 3 2 2 13 SET 15 MAIN UTENTE MONITOR MENU ESTESO MENU ESTESO PASSWORD PASSWORD Setpoint 15 14 16...
Страница 581: ...579 17 15 15 3 4 Password inverter password password inverter password PW 6 6 16 GO SB FAULT...
Страница 623: ...ROM N 621 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Страница 684: ...POLSKI 682 Rys 2 Mocowanie oraz minimalna odleg o na potrzeby cyrkulacji powietrza...
Страница 745: ...MAGYAR 743 2 bra R gz t s s minim lis t vols g a szell z leveg kering se rdek ben...
Страница 800: ...798 IEC 364 1...
Страница 801: ...799 1 3 1 1...
Страница 805: ...803 1 2 1 1 1 1 2 5 2 1 2 1 2 C...
Страница 806: ...804 2...
Страница 807: ...805 2 2 3 3 15 2 2 1 1 2a...
Страница 808: ...806 4a 5b 1b V 127 240 240 480 3 6 3b...
Страница 812: ...810 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Страница 814: ...812 10 4 20 A 7 4 20 A 4 20 A 18 J5 GND 1 J5 GND o 11 J5 o 7 J5 8 J5 7 J5 8 10 J5 4 20mA 7 8 10 11...
Страница 817: ...815 V 36 36 12V A 3 3 3 3 2 13 9 11 8 13...
Страница 819: ...817 3 14 64 X 128 4 MODE SET and 12 9 MODE 1 SET 11 3 EEprom SET 6 SET MODE 3 1 11...
Страница 820: ...818 3 2 1 2 3 2 1 10 2 2 5 5 5 2 2 12...
Страница 824: ...822 15 3 4 GO SB FAULT...
Страница 825: ...823 4 4 1 8 4 2 4 2 1 16 18...
Страница 828: ...826 4 3 1 3 SET MODE LA RC MS FS SO AE O1 1 O2 2 4 4 2 2 4 2 5 4 5 FL 4 5 1 4 5 1 1 ET ET ET ET 0 ET 6 6 9 4 5 1 2...
Страница 832: ...830 6 6 1 MODE MODE 6 1 1 FR Hz 6 1 2 VP bar psi 6 1 3 C1 A C1 RC 6 5 1 6 1 4 PO kW PO 6 1 5 SM SB F 17 RC A SM...
Страница 862: ...ESKY 860 Obr zek 2 P ipevn n a minim ln vzd lenost kv li cirkulaci vzduchu...
Страница 917: ...915 IEC 60634 1...
Страница 918: ...916 1 6 1 1...
Страница 922: ...920 1 2 1 1 1 1 2 5 2 1 2 1 2 2...
Страница 923: ...921 2...
Страница 924: ...922 2 2 3 3 15 2 2 1 1a 2a...
Страница 925: ...923 4a 5b 1b 127 240 240 480 3 6 3b...
Страница 929: ...927 2 2 2 GP GI 6 6 4 6 6 5 8 A B C D...
Страница 931: ...929 10 4 20 6 4 20 PR 6 5 7 4 20 2 18 J5 GND 1 J5 GND o IN 11 J5 4 20 7 OUT 8 10 11 IN...
Страница 932: ...930 o OUT 7 J5 8 J5 1 7 J5 2 8 10 J5 9 11 4 20 PR 6 5 7 BP1 2 2 3 2 Flow 7 DIN 43650 6 0 5 DIN 43650 4 20 A OUT B IN C D...
Страница 934: ...932 2 2 4 2 18 J5 1 I 1 16 17 I 2 15 16 I 3 13 14 I 4 12 13 50 60 7 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 8 11 8...
Страница 935: ...933 13 J5 I1 11 17 16 18 16 17 I2 11 15 16 18 15 16 I3 11 14 13 18 13 14 I4 11 12 13 8 12 13 9...
Страница 936: ...934 11 I1 1 I2 3 I3 5 I4 10 I1 F1 I1 6 6 13 2 I2 P2 6 6 13 3 I3 F3 6 6 13 4 I4 1 F4 6 6 13 5 11 V GND 7 I1 I2 I3 I4...
Страница 937: ...935 3 14 64 X 128 4 MODE SET 12 9 MODE 1 SET 10 3 EEprom SET 6 SET MODE 3 1 11...
Страница 938: ...936 3 2 1 2 3 2 1 MODE SET MODE 10 2 2 5 5 5 2 2 11...
Страница 940: ...938 3 2 2 13 SET 15 15 14 16...
Страница 941: ...939 3 3 psi 12 13 GO SB BL LP HP EC OC OF SC OT OB BP NC F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E0 E16 0 16 EE EEprom WARN...
Страница 942: ...940 17 14 15 3 4 PW 6 6 16 GO SB FAULT...
Страница 943: ...941 4 4 1 Link 8 4 2 4 2 1 Link Link 16 18 Link...
Страница 946: ...944 4 3 1 2 1 4 3 1 3 SET MODE LA RC MS FS SO AE O1 1 O2 2 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL...
Страница 951: ...949 6 6 1 MODE MODE 6 1 1 FR 6 1 2 VP psi 6 1 3 C1 A C1 RC 6 5 1 6 1 4 PO PO 6 1 5 SM 15 SB F 16 SM 15 Sb F RC A...
Страница 952: ...950 SM 6 1 6 VE 26 1 0 S 5 6 2 2 SET MODE 6 2 1 VF 6 2 2 TE 6 2 3 BT 6 2 4 FF FF x y x y x 1 x y 64 RF 6 2 5 CT 6 2 6 LA...
Страница 969: ...967 10 0 Mode Set PW 0 PW 2 7 3 6 6 16 1 PW PW PW PW 0 PW 0 0 PW PW PW PW PW 0 PW...