background image

DAAB INTERFACE CARD DB409 INSTRUCTION MANUAL

Revision 7 

7

•  Setting of frequency converter

Note that the switches above the terminal block must be in the upward position! (NPN/AVI)

Содержание DB409

Страница 1: ...trol unit EP104 version 4 08 EP105 INSTRUCTION MANUAL DAAB INTERFACE CARD DB409 FOR FREQUENCY CONVERTER VFD EL FAAC Nordic AB BOX 125 SE 284 22 PERSTORP SWEDEN 46 435 77 95 00 support faac se www faac...

Страница 2: ...ter and the automatic control unit may be permanently damaged Pick out the following EP104 1 EP104 2 The cable in X12 The cable in X12 The cable in X7 The cables between X4 and X11 The illustration sh...

Страница 3: ...nd the automatic control unit may be permanently damaged Pick out the following EP105 1 EP105 2 The cable in X12 The cable in X12 The cable in X7 The cables between X4 and X11 The illustration shows E...

Страница 4: ...tomatic control unit Power Must not be used Network cable L1 C1 L1 1 L1 C1 L1 1 L2 1 L3 1 Important BEFORE connection takes place the cable in X12 must be removed A Mains connection B Control panel C...

Страница 5: ...C1 L1 C2 L2 1 L3 1 L1 1 L1 2 L3 2 L2 2 Power Must not be used L1 C1 L1 C2 L2 1 L3 1 L1 1 L1 2 L3 2 L2 2 Important BEFORE connection takes place the following cables must be removed The cables between...

Страница 6: ...shows H for the output frequency concerned Tip By pressing MODE once more when stepping between the program channels you change to stepping between the program groups instead Channel settings in the f...

Страница 7: ...DAAB INTERFACE CARD DB409 INSTRUCTION MANUAL Revision 7 7 Setting of frequency converter Note that the switches above the terminal block must be in the upward position NPN AVI...

Страница 8: ...io is not stated in the documentation belonging to the motor winder a measurement can be done by displaying channel F031 or F041 and then letting the motor winder open or close until a value appears a...

Страница 9: ...in channel F005 and how long it is to go on is selected in the channels for run on In optimal adjustment there must be time for the frequency in F008 and F009 to be read on the display on the frequenc...

Страница 10: ...Hz 0 5 9 9 seconds 2 0 F008 Low speed frequency for opening movement motor 1 and 2 5 20 Hz 5 F009 Low speed frequency for closing movement motor 1 and 2 5 20 Hz 10 F012 Opening frequency Opening speed...

Страница 11: ...min ratio 1485 1 F031 Measured ratio motor 1 Only when F030 0 0 9999 F040 Choice of ratio for motor 2 0 9 0 0 Not selected in this position the motor only rotates at 25Hz 1 MK with pulleys 40 71 ratio...

Страница 12: ......

Отзывы: