4
TENSIONED COSMOPOLITAN
®
ELECTROL
®
INSTALLATION
LOW-VOLTAGE WALL SWITCH
OPTIONAL IR AND RF
REMOTE CONTROL
MOTOR
BLUE (COMMON)
BROWN (HOT)
GREEN
GROUND TO CASE
240VAC 50HZ
240V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
RJ9
UP
STOP
DOWN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
RJ9
GREEN
FRONT
BACK
UP DN
GND +5V
3-POSITION
SWITCH
RJ9
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
DRY CONTACTS
SPLITTER
UP
+5V
COM
DN
IMPORTANT NOTE:
The wall switch is REQUIRED to make any limit
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the
switch or provide a 4-conductor connection that is
accessible.
CONNECT SUPPLIED
RJ9 CABLE TO
SPLITTER AND
SWITCH, OR USE 4
CABLE CONDUCTOR
TO CONNECT TO
SCREW TERMINALS.
The screen surface travel is stopped automatically in the fully opened and closed positions by limit switches that are
properly adjusted at Da-Lite. The screen should not be adjusted for more or less drop. The fabric cables are adjusted for
proper vertical and lateral tension at Da-Lite.
SCREEN ADJUSTMENT
CONTACT DA-LITE AT 800-622-3737 OR 574-267-8101 IF SCREEN MOTOR NEEDS ADJUSTMENT.
s
!
Содержание Tensioned Cosmopolitan electrol
Страница 7: ...6 ...