DXS-3600 Series 10GbE Layer 2/3 Switch Hardware Installation Guide 

Features 

This switch is action packed with an abundance of networking features that span inside and outside of the traditional 

Layer 3 framework. The list below highlights the significant protocols and features supported by this switch. 
 
Features that can be found on this switch are: 
 

  D-Link License Management System (DLMS) 

  Jumbo Frames (12 KBytes) 

  Port Mirroring 

  Priority-based Flow Control (PFC) 

  IGMP Snooping (Versions 1, 2, 3) 

  Secure Shell (SSH) 

  Port-based VLAN 

  VLAN Trunking 

  Subnet-based VLAN 

  VLAN Translation 

  Queue Handling 

  Bandwidth Control 

  Congestion Control 

  Time Based ACL 

  Port Security 

  BPDU Attack Protection 

  802.1X Network Access Control 

  Guest VLAN 

  RADIUS Accounting 

  Link Layer Discovery Protocol (LLDP) 

  Web-based Graphical User Interface (Web 

GUI) 

  Traffic Monitoring 

  TFTP Client 

  Simple Network Management Protocol (SNMP) 

  DHCP Server and Client 

  DHCP Relay 

  Multiple Image and Configuration 

  Password Recovery and Encryption 

  Debug Command 

  DNS Resolver and Relay 

  Routing Information Protocol (RIP) 

  Border Gateway Protocol (BGP) 

  Route Preference and Distribution 

  Multicast Duplication 

  Distance Vector Multicast Routing Protocol 

(DVMRP) 

  IP Interface 

  Spanning Tree Protocol (STP, RSTP, MSTP) 

  Link Aggregation 

  Layer 2 Multicast Filtering 

  IGMP and MLD Proxy 

  802.1Q VLAN 

  MAC-based VLAN 

  Private VLAN 

  Q-in-Q 

  Quality of Service (QoS) 

  Class of Service (CoS) 

  Three Color Marker 

  Access Control List (ACL) 

  Traffic Segmentation 

  Broadcast/Multicast/DLF Storm Control 

  DoS Prevention 

  Access Authentication Control (AAA) 

  User Account Privilege for Management 

Access 

  Address Resolution Protocol (ARP) 

  Static Routing 

  Command Line Interface (CLI) 

  Telnet Server and Client 

  FTP Client 

  System Log 

  CPU Monitoring 

  Trap/ Log Severity Control 

  Flash File System (FFS) 

  Simple Network Time Protocol (SNTP) 

  Traceroute and Ping 

  Virtual Router Redundancy Protocol (VRRP) 

  Open Shortest Path First (OSPF) 

  Multicast Listener Discovery (MLD) 

  Internet Group Management Protocol (IGMP) 

  Protocol Independent Multicast (DM, SM, SSM, 

Sparse-Dense) 

  Management Information Base (MIBs) for 

MIBII, Bridge MIB, SNMPv2 MIB, RMON MIB, 
RMONv2 MIB, Ether-like MIB, 802.3 MAU MIB, 
802.1p MIB, IF MIB, RADIUS Authentication 
Client MIB, IGMPv3 MIB, RIPv2 MIB, IP 
Forwarding Table MIB (CIDR), IPv4 Multicast 
Routing MIB, PIM MIB for IPv4, RADIUS 
Accounting Client MIB, Ping MIB, Trace out 

Содержание DXS-3600 Series

Страница 1: ...SBG 3000 Series Web Smart Switch Hardware Installation Guide ...

Страница 2: ...used in accordance with this manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may...

Страница 3: ...r New Font This font is used to indicate CLI command examples used in this document Initial capital letter The use of initial capital letters indicates that a referral to a specific name was made This will be seen a lot when referring to protocols standards keyboard keys and when we refer to the Switch as a generic name for all switches with in the series For example Click Enter Menu Name Menu Opt...

Страница 4: ...ble that is approved for use in your country The power cable must be rated for the product and for the voltage and current marked on the product s electrical ratings label The voltage and current rating of the cable should be greater than the ratings marked on the product To help prevent electric shock plug the system and peripheral power cables into properly grounded electrical outlets These cabl...

Страница 5: ... locking position and then slide the component into the rack Do not overload the AC supply branch circuit that provides power to the rack The total rack load should not exceed 80 percent of the branch circuit rating Ensure that proper airflow is provided to components in the rack Do not step on or stand on any component when servicing other components in a rack CAUTION Never defeat the ground cond...

Страница 6: ...ng Transceivers into the Transceiver Ports 15 Installing Power Modules into the Power Module Ports 16 Installing an AC Power Module 16 Installing a DC Power Module 17 Installing Fan Modules into the Fan Module Ports 18 Switch Connections 20 Switch to End Node 20 Switch to another Switch 20 Switch Stacking 21 Switch to a Server 23 Switch Management 24 Management Options 24 Connecting to the Console...

Страница 7: ...sing the Graphical User Interface GUI and Command Line CLI IEEE 802 1X ports and MAC based authentication help provide added network security by requiring all users attempting to connect to your network to provide a username and password This username and password must then be authenticated on a RADIUS or TACACS server ensuring only authorized users have access to the network Access Control Lists ...

Страница 8: ...way Protocol BGP Route Preference and Distribution Multicast Duplication Distance Vector Multicast Routing Protocol DVMRP IP Interface Spanning Tree Protocol STP RSTP MSTP Link Aggregation Layer 2 Multicast Filtering IGMP and MLD Proxy 802 1Q VLAN MAC based VLAN Private VLAN Q in Q Quality of Service QoS Class of Service CoS Three Color Marker Access Control List ACL Traffic Segmentation Broadcast...

Страница 9: ... port that can be used to connect to the Command Line Interface CLI of this switch for configuration management and monitoring This port uses a special console cable included with the packing with a DB9 interface to connect the Switch to a PC s COM port 10 Gigabit ports This switch is equipped with SFP SFP WDM ports These ports can operate at 10Gbps speeds and support a vast collection of SFP SFP ...

Страница 10: ...the DXS 3600 32S with EM 8XS module Figure 1 7 Front panel view of the DXS 3600 32S with EM Stack module LED Indicators Located on the front panel of the switch are LED indicators Power1 Power2 MGMT Console Fan1 Fan2 Fan3 and SD Additionally the DXS 3600 32S also has a Seven segment stacking ID LED For each SFP port there is a Link Act light Figure 1 8 LED indicators for the DXS 3600 16S Figure 1 ...

Страница 11: ...is not receiving power SD This LED will light solid green if a Secure Digital SD card is plugged in This LED will blink green when the Switch is reading or writing data to and from the SD card This LED will be off when no SD card is plugged into the SD port This LED will light solid red when an SD card failure has been detected Link Act LEDs This LED will light solid green when there is a secure c...

Страница 12: ...C power connector and the other end into a properly grounded electrical outlet The switch will automatically adjust the power setting to adapt to any voltage supply in the range from 100 240VAC at 50 60Hz In addition an optional second power supply module can be plugged into the second power supply connector slot displayed above When the primary power connection fails the secondary power connectio...

Страница 13: ... heat Do not block these openings Leave at least 4 inches of space at the rear and sides of the switch for proper ventilation Be reminded that without proper heat dissipation and air circulation system components might overheat which could lead to system failure or even severely damage components Figure 1 12 Side panels of the DXS 3600 16S Figure 1 13 Side panels of the DXS 3600 32S ...

Страница 14: ...otors vibration dust and direct exposure to sunlight Installing the Switch without a Rack This section is used to guide the user through installing the switch in an area other than a switch rack Attach the rubber feet included to the bottom of the switch Take note that there should be marked blocks on the bottom of the switch to indicate where to attach the rubber feet These marking are usually fo...

Страница 15: ...et C in the appropriate open space in the rack using the screws provided as seen in the figure below 3 Simply slide the switch fastened bracket B into fastened bracket C into the rack 4 Lastly fasten mounting bracket A to the rack using the screws provided Figure 2 3 Installing the Switch in a rack Make sure that there is adequate space around the Switch to allow for proper air flow ventilation an...

Страница 16: ...les into the Power Module Ports The power module slots located on the rear panel of this switch support two types of power supply modules AC Power Supply Module DXS 3600 PWR FB A 300W AC power supply tray with front to back airflow DXS 3600 PWR BF A 300W AC power supply tray with back to front airflow DC Power Supply Module DXS 3600 PWRDC FB A 300W DC power supply tray with front to back airflow N...

Страница 17: ...le meaning that they can be inserted and removed while the switch is powered on This feature enhances the reliability of this switch Installing a DC Power Module This switch supports a unique dual power input feature Connect the one end of the DC power cord supplied to a DC power source 48VDC 5 2A that will be activated when the AC power is not working Please make sure that connection polarity pos...

Страница 18: ...s wire size must be 18AWG Connect the DC power cable to a DC main circuit breaker rated no greater than 15A If you are installing a DC powered switch you must ground the chassis before connecting the switch to the DC power source following the following instructions Use a minimum of 18 AWG stranded copper wire for grounding The wire should be long enough to reach from the installed switch to the f...

Страница 19: ...nstallation Guide 19 NOTE The Power Modules all support a specific air flow direction This air flow direction must be the same as the Fan Module installed By default the air flow direction of the Power Module and Fan Module installed is front to back ...

Страница 20: ...hat packet activity is taking place on that port The diagram below display a typical end node connected to the Switch Figure 3 1 Connecting the Switch to an End Node Switch to another Switch Another popular configuration is to connect this switch to another switch or hub This network typography is considered when one Switch does not have enough ports to cater for all the end nodes in the network T...

Страница 21: ...transfer is only possible in one direction and if there is a break in the chain then data transfer will obviously be affected Duplex Ring The Duplex Ring stacks switches in a ring or circle format where data can be transferred in two directions This topology is very resilient due to the fact that if there is a break in the ring data can still be transferred through the stacking cables between swit...

Страница 22: ...ely uses the last two QSFP ports to make the following stacking topologies The figure below illustrates how switches can be stacked in a Duplex Chain formation using the DXS 3600 EM 4QXS module Figure 3 5 Duplex Chain physical stack using the DXS 3600 EM 4QXS module The figure below illustrates how switches can be stacked in a Duplex Ring formation using the DXS 3600 EM 4QXS module ...

Страница 23: ...t likely have to add a server or two to this switch Generally any port on this switch can be used to connect to a server as they all operate at a maximum speed of one 10Gbps What sets this switch apart is the fact that there are powerful software applications available on this switch that specifically caters for better server access management and security Figure 3 7 Connecting the Switch to a ser...

Страница 24: ...and counters Web based Management Interface After successfully installing the switch the user can configure the switch monitor the LED panel and display statistics graphically using a Web browser such as Microsoft Internet Explorer version 6 0 and later Mozilla Firefox version 3 0 and later Safari version 4 0 and later Google Chrome version 5 0 and later Opera version 9 0 and later and Netscape ve...

Страница 25: ... for Function Arrow and Ctrl keys Make sure to use Terminal keys not Windows keys are selected Figure 4 2 COM1 Properties General Settings NOTE When using HyperTerminal with the Microsoft Windows 2000 operating system ensure that Windows 2000 Service Pack 2 or later is installed Windows 2000 Service Pack 2 allows use of arrow keys in HyperTerminal s VT100 emulation See www microsoft com for inform...

Страница 26: ...ware Build 2 40 038 Copyright C 2015 D Link Corporation All rights reserved Switch Figure 4 4 The Switch s Login Screen By default there is no Username and Password configured in the account settings of this switch This will allow the user to simply connect to this Switch for the first time by pressing the Enter key After pressing Enter access will be given to enter commands after the command prom...

Страница 27: ...NMP network manager or other TCP IP applications The switch s console default IP address is 10 90 90 90 8 and the management port default IP address is 192 168 0 1 24 You can change the switch s default IP address to fit into your networking address range The IP address of the Switch must be configured before it can be managed by the user via the Web User Interface An example to change the IP addr...

Страница 28: ...anaged objects is maintained by the SNMP agent and used to manage the device These objects are defined in a Management Information Base MIB which provides a standard presentation of the information controlled by the on board SNMP agent SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network This switch supports SNMPv1 SNMPv2c and SNM...

Страница 29: ... events that occur on the switch The events can be as serious as a reboot someone accidentally turned OFF the switch or less serious like a port status change The switch generates traps and sends them to the trap recipient or network manager Typical traps include trap messages for Authentication Failure and Topology Change Management Information Base MIB The Management Information Base MIB stores ...

Страница 30: ...on this Switch Below we have an example of how to access the Web User Interface from a normal LAN port The IP address configured for this port is 10 90 90 90 For more information about configuring the IP address refer to Configuring the IP Address on page 23 Figure 4 9 Displays entering the IP address in Internet Explorer This will open the user authentication window as seen below Figure 4 10 Ente...

Страница 31: ...ns including port monitoring are accessible from here Click the D Link to go to the D Link website AREA 2 This area displays a file explorer type menu tree of all configurable options Select the folder or window to display Open folders and click the hyperlinked window buttons and subfolders contained within them to display information pertaining to that category AREA 3 This area displays a toolbar...

Страница 32: ... DXS 3600 32S Supports 4 stacking units with EM Stack EM 4QXS modules DXS 3600 16S Supports 4 stacking units with EM 4QXS modules via the last two ports Virtual Stacking Clustering Support D Link Single IP Management v1 61 Use a single IP to manage the virtual stack with up to 32 D Link Layer 2 3 switches Performance Specifications Switch Capacity DXS 3600 16S 480Gbps DXS 3600 32S 960Gbps Packet F...

Страница 33: ...2 3ab compliance DXS 3600 EM 4XT Expansion Module 10GBASE T ports compliant to the following standards IEEE 802 3an compliance SFP Ports Compliant to following standards IEEE 802 3z compliance IEEE 802 3x Flow Control support for Full Duplex mode Support Auto negotiation for Full Duplex flow control operations SFP Transceivers Supported DEM 310GT 1000BASE LX Single mode 10km DEM 311GT 1000BASE SX ...

Страница 34: ... CWDM SFP Transceiver 1571nm SFP Direct Attached Cables DAC Direct Attached Cables are cables with built in SFP transceivers at both ends DEM CB100S 10GbE SFP 1m Direct Attach Cable DEM CB300S 10GbE SFP 3m Direct Attach Cable DEM CB700S 10GbE SFP 7m Direct Attach Cable QSFP Ports Compliant to following standards IEEE 802 3ba compliance IEEE 802 3ae compliance QSFP Expansion Module DXS 3600 EM 4QXS...

Страница 35: ...ght on Solid Console on Light off Console off Fan 1 Fan 2 Fan 3 Green Light on Solid Diagnostics pass Functioning normal Light off No Power Amber Light on Solid Busy booting or running diagnostics Light blinking Fan failure or reversed airflow fan was inserted SD Green Light on Solid SD plugged in Light blinking Busy reading writing Light off No link Red Light on Solid Read Write failure Stacking ...

Страница 36: ...hen there is reception or transmission of data occurring at 10 100Mbps Off Light off No link LED Per Port SFP 10Gbps Link Act Speed Green Light on Solid When there is a secure connection or link to 10Gbps Ethernet device at any of the ports Light blinking When there is reception or transmission of data occurring at 10Gbps Amber Light on Solid When there is a secure connection or link to 1000Mbps E...

Страница 37: ...s Description Light blinking When there is reception or transmission of data occurring at 10 40Gbps Amber Light on Solid When there is a secure connection or link to 1Gbps Ethernet device at any of the ports Light blinking When there is reception or transmission of data occurring at 1Gbps Off Light off No link ...

Страница 38: ...pin assignments Figure B 1 Standard RJ 45 port and connector RJ 45 Pin Assignment Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 1000BASE T 1000BASE T 8 1000BASE T 1000BASE T Console Cable A console cable is used when a user want to connect to the console port of th...

Страница 39: ...witch Hardware Installation Guide 39 Figure B 2 Console to RJ 45 Cable Contact Console DB9 RS232 RJ 45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Страница 40: ...iquidators expressly disclaim their warranty obligation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return poli...

Страница 41: ...opyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without...

Страница 42: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Страница 43: ...onfiguration Please refer to the user manual to learn more or visit http www mydlink com for more information Also feel free to contact us U S and Canadian customers can contact D Link Technical Support through our website USA http support dlink com Canada http support dlink ca ...

Страница 44: ...SISTENCIA TÉCNICA SUPPORTO TECNICO TECHNISCHE ONDERSTEUNING POMOC TECHNICZNA TECHNICKÁ PODPORA TECHNICKÁ PODPORA TECHNIKAI TÁMOGATÁS TEKNISK SUPPORT TEKNISK SUPPORT TEKNISK STØTTE TEKNINEN TUKI ASSISTÊNCIA TÉCNICA ΤΕΧΝΙΚΉ ΥΠΟΣΤΉΡΙΞΗ TEHNIČKA PODRŠKA TEHNIČNA PODPORA SUPORT TEHNIC ТЕХНИЧЕСКА ПОДДРЪЖКА ...

Страница 45: ...and Indonesia Malaysia Philippines Vietnam customers Singapore www dlink com sg Thailand www dlink co th Indonesia www dlink co id Malaysia www dlink com my Philippines www dlink com ph Vietnam www dlink com vn Korea customers Tel 82 2 2028 1810 Monday to Friday 9 00am to 6 00pm Web http d link co kr E mail g2b d link co kr New Zealandcustomers Tel 0800 900 900 24 7 Technical Support Web http www ...

Страница 46: ... 971 4 8809033 General Inquiries info me dlinkmea com Tech Support support me dlinkmea com Egypt customers 1 Makram Ebeid Street City Light Building floor 5 Nasrcity Cairo Egypt Tel 2 02 23521593 2 02 23520852 Technical Support 2 02 26738470 General Inquiries info eg dlinkmea com Tech Support support eg dlinkmea com Kingdom of Saudi Arabia customers Office 84 Al Khaleej Building Mujamathu Al Khale...

Страница 47: ...echnical Support 92 21 34548310 34305069 General Inquiries info pk dlinkmea com Tech Support support pk dlinkmea com Iran customers Unit 5 5th Floor No 20 17th Alley Bokharest St Argentine Sq Tehran IRAN Postal Code 1513833817 Tel 98 21 88880918 19 98 21 88706653 54 General Inquiries info ir dlinkmea com Tech Support support ir dlinkmea com Morocco customers M I T C Route de Nouaceur angle RS et C...

Страница 48: ... Support 973 1 3332904 Kuwait customers Technical Support 965 22453939 965 22453949 Türkiye customers Büyükdere Cad Ferro Plaza No 155 D 1 K 1 Zincirlikuyu Istanbul Tel 90 212 289 56 59 Email info tr dlink com tr לארשי ןולטמ רטנס חר םימישגמה 20 תירק ןולטמ פ ת 49348 ת ד 7060 לט 03 9215173 לט 073 7962797 אוד ל יללכ info dlink co il אוד ל הכימת support dlink co il ...

Страница 49: ...pport dlink ru Офисы Россия Москва Графский переулок 14 Тел 7 495 744 00 99 E mail mail dlink ru Україна Київ вул Межигірська 87 А Тел 38 044 545 64 40 E mail ua dlink ua Moldova Chisinau str C Negruzzi 8 Tel 373 22 80 81 07 E mail info dlink md Беларусь Мінск пр т Незалежнасці 169 Тэл 375 17 218 13 65 E mail support dlink by Қазақстан Алматы қ Құрманғазы 143 үй Тел 7 727 378 55 90 E mail almaty d...

Страница 50: ...avor revise el número telefónico del Call Center de su país en http www dlinkla com soporte call center Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dlinkla com consultas dlinkla com ...

Страница 51: ...Clientes de Brasil Caso tenha dúvidas na instalação do produto entre em contato com o Suporte Técnico D Link Acesse o site www dlink com br suporte ...

Страница 52: ... D Link 免付費技術諮詢專線 0800 002 615 手機付費電話 02 6600 0123 8715 服務時間 週一至週五 早上9 00到晚上9 00 週六日及國定假日 不含農曆春節 早上10 00到晚上7 00 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站 全球各地分公司 的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Страница 53: ... 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id 日本のお客様 この度は弊社製品をお買い上げいただき 誠にありがとうございます 製品に同梱されている保証書の購入元にお問い合わせください 中國客戶 辦公地址 北京市朝陽區將台路5號院5號樓 郵編 100016 技術支持中心電話 400 629 6688 技術支持中心傳真 028 61317620 各地維修中心地址請登陸官方網站查詢 網址 http www dlink com cn 400電話工作時間 工作日9 00 19 00 節假日9 00 18 00 ...

Страница 54: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Страница 55: ......

Отзывы: