background image

 

38 

the network, preventing the effective propagation of the new 
information. Set by the Root Bridge, this value will aid in determining 
that the Switch has spanning tree configuration values consistent with 
other devices on the bridged LAN. If the value ages out and a BPDU 
has still not been received from the Root Bridge, the Switch will start 
sending its own BPDU to all other switches for permission to become 
the Root Bridge. If it turns out that your switch has the lowest Bridge 
Identifier, it will become the Root Bridge. The user may choose a time 
between 6 and 40 seconds. The default value is 20. 

Bridge Hello Time:

 The user may set the time interval between 

transmission of configuration messages by the root device, thus 
stating that the Switch is still functioning. A time between 1 and 10 
seconds may be chosen, with a default setting of 2 seconds. 

Bridge Forward Delay:

 The maximum amount of time (in seconds) 

that the root device will wait before changing states. The user may 
choose a time between 4 and 30 seconds. The default is 15 seconds. 

Port Path Cost:

 This defines a metric that indicates the relative cost 

of forwarding packets to specified port list. The value between 1 and 
65535 to determine the cost. The lower the number, the greater the 
probability the port will be chosen to forward packets. The default 
value is 10. 

Port Path Priority: 

Select a value between 0 and 255 to specify the 

priority for a specified port for forwarding packets. The lower the 
value, the higher the priority. The default is 128. 
 
 
 

Содержание DES-2110

Страница 1: ...DES 2110 8 port 10 100 1 port 1000Base T Copper 1 port miniGBIC Gigabit Switch User s Guide ...

Страница 2: ......

Страница 3: ...nd can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environ...

Страница 4: ......

Страница 5: ... Technology 3 Gigabit Ethernet Technology 3 Switching Technology 4 Switch Description 5 Features 6 Ports 8 Unpacking and Setup 9 Unpacking 9 Setup 9 Installing the Switch on a Desktop 10 Installing the Switch on a Rack 11 Power on 12 Identifying External Components 13 Front Panel Components 13 Rear Panel 14 ...

Страница 6: ...on To Switch Management 17 Management Options 17 Web Management Utility 17 Web based Management Interface 17 Command Line Interface CLI 18 SNMP Based Management 18 Configuration The Switch 19 Web Management Utility 19 Installing the Web Management Utility 19 Discovery List 20 Monitor List 21 Device Setting 23 Toolbar 25 Configuring the Switch using Web Browser 26 Login to Web Manager 27 ...

Страница 7: ...Tree Setting 37 SNMP Setting 39 Static MAC 45 IGMP Snooping Setting 47 Device Status 49 Statistic 50 System Setting 51 Trap Setting 52 Set Password 53 Backup Setting 54 Reset Setting 54 Logout 55 Configuring the Switch using the CLI 56 IP Address of the Switch 56 Using the CLI via Telnet interface 57 Command Syntax 58 ...

Страница 8: ... Commands 60 Basic IP Commands 65 Switch Port Commands 67 VLAN Commands 71 Port Mirroring Commands 79 Trap Commands 82 Spanning Tree Commands 87 SNMP Commands 95 IGMP Snooping Commands 102 Technical Specifications 108 ...

Страница 9: ...Ethernet switches including the DES 2110 Overview of this User s Guide Introduction Describes the Switch and its features Unpacking and Setup Helps you get started with the basic installation of the Switch Identifying External Components Describes the front panel rear panel and LED indicators of the Switch Configuration the Switch Tell to how to configuration the management functions of the Switch...

Страница 10: ......

Страница 11: ...ndard specified by the IEEE 802 3 LAN committee It is an extension of the 10Mbps Ethernet standard with the ability to transmit and receive data at 100Mbps while maintaining the Carrier Sense Multiple Access with Collision Detection CSMA CD Ethernet protocol Gigabit Ethernet Technology Gigabit Ethernet is an extension of IEEE 802 3 Ethernet utilizing the same packet structure format and support fo...

Страница 12: ...henomenal bandwidth delivered by Gigabit Ethernet is the most cost effective method to take advantage of today and tomorrow s rapidly improving switching and routing internetworking technologies Switching Technology Another key development pushing the limits of Ethernet technology is in the field of switching technology A switch bridges Ethernet packets at the MAC address level of the Ethernet pro...

Страница 13: ...y is a marked improvement over the previous generation of network bridges which were characterized by higher latencies Routers have also been used to segment local area networks but the cost of a router and the setup and maintenance required make routers relatively impractical Today s switches are an ideal solution to most kinds of local area network congestion problems Switch Description The DES ...

Страница 14: ...uing VLANs and port monitoring and port speed Features The DES 2110 was designed for easy installation and high performance in an environment where traffic on the network and the number of users increase continuously The Switch features include IEEE 802 3 10BASE T compliant IEEE 802 3u 100BASE TX compliant IEEE 802 3ab 1000BASE T compliant IEEE 802 3x flow control in full duplex mode IEEE 802 1Q V...

Страница 15: ...store and forward switching scheme capability to support rate adaptation and protocol conversion Efficient self learning and address recognition mechanism enables forwarding rate at wire speed Support port based enable and disable Address table Supports up to 4K MAC addresses per device Supports a packet buffer of up to 256 Kbytes IGMP Snooping support SNMP support Port Mirror support MIB support ...

Страница 16: ...between 10Mbps and 100Mbps half duplex and full duplex and flow control One 1 10 100 1000Mbps 1000BASE T Auto MDI X MDI II port for connecting to end station server switch or other networking devices The port can auto negotiate between 10Mbps 100Mbps and 1000Mbps half duplex and full duplex and flow control One 1 mini GBIC port for option mini GBIC transceiver module ...

Страница 17: ...two brackets and screws CD ROM This User s Guide and Utility If any item is found missing or damaged please contact your local reseller for replacement Setup The setup of the Switch can be performed using the following steps Install the Switch on a sturdy level surface that can support at least 6 6 lb 3 kg of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 me...

Страница 18: ... as motors vibration dust and direct exposure to sunlight When installing the Switch on a level surface attach the rubber feet to the bottom of the device The rubber feet cushion the Switch protect the casing from scratches and prevent it from scratching other surfaces Installing the Switch on a Desktop When installing the Switch on a desktop or shelf the rubber feet included with the Switch shoul...

Страница 19: ...the following diagrams to guide you Figure 2 Fasten mounting brackets to Switch Fasten the mounting brackets to the Switch using the screws provided With the brackets attached securely you can mount the Switch in a standard rack as shown in Figure 2 2 on the following page Mounting the Switch in a Standard 19 Rack 11 ...

Страница 20: ...power supply will adjust to the local power source automatically Plug one end of the AC power cord into the power connector of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will momentarily blink This blinking of the LED indicators represents a reset of the system ...

Страница 21: ...panel view Port 1 8 Eight 10 100Mbps Fast Ethernet ports Port 9 One 10 100 1000Mbps Gigabit Ethernet ports port 9 Port 10 One mini GBIC port port 10 LED Indicators Comprehensive LED indicators that display the conditions of the Switch and status of the network A description of these LED indicators follows see LED Indicators Reset The Reset button is to reset all the setting back to the factory def...

Страница 22: ... the provided power cord into this socket and the male side of the cord into a power outlet The Switch automatically adjusts its power setting to any supply voltage in the range from 100 240 VAC at 50 60 Hz LED Indicators The LED indicators of the Switch include Power CPU and Port Status LEDs The following shows the LED indicators for the Switch along with an explanation of each indicator Figure 6...

Страница 23: ...U is not working Ports 1 8 10 100M Fast Ethernet Ports Status LEDs Link Act On When the Link Act LED lights on the respective port is successfully connected to an Ethernet network Blinking When the Link Act LED is blinking the port is transmitting or receiving data on the Ethernet network Off No link 100M On When the 100Mbps LED lights on the respective port is connected to a 100Mbps Fast Ethernet...

Страница 24: ...bit Ethernet network 1000M On When the 100Mbps LED lights on the respective port is connected to a 100Mbps Fast Ethernet network Off When the respective port is connected to a 10Mbps Ethernet or 100Mbps Fast Ethernet network Port 10 mini GBIC Port Status LEDs Link Act On When the mini GBIC module is installed and connected to a network the Link Act LED lights on Blinking When the LED is blinking t...

Страница 25: ...anagement accessible through a web browser Web Management Utility With the Web Management Utility you can easily discover all the Web Management Switch assign the IP Address changing the password and upgrading the new firmware Web based Management Interface After you have successfully installed the Switch you can configure the Switch display statistics using a web browser such as Netscape Navigato...

Страница 26: ...sing the TCP IP Telnet protocol SNMP Based Management You can manage the Switch with an SNMP compatible console program The Switch supports SNMP version 1 0 The SNMP agent decodes the incoming SNMP messages and responds to requests with MIB objects stored in the database The SNMP agent updates the MIB objects to generate statistics and counters ...

Страница 27: ...irmware Installing the Web Management Utility The following gives instructions guiding you through the installations of the Web Management utility 1 Insert the Utility CD in the CD Rom Drive 2 From the Start menu on the Windows desktop choose Run 3 In the Run dialog box type D Web Management Utility setup exe D depends where your CD Rom drive is located and click OK 4 Follow the on screen instruct...

Страница 28: ... instruction follow the below section Discovery List This is the list where you can discover all the Web management devices in the entire network By pressing the Discovery button you can list all the Web Management devices in the discovery list Double click or press the Add to monitor list button to select a device from the Discovery List to the Monitor List 20 ...

Страница 29: ...ll the Web Smart Device in the Monitor List can be monitored you can also receive the trap and show the status of the device System word definitions in the Monitor List S Shows the system symbol of the Web Smart device represent for device system is not alive IP Address Shows the current IP address of the device MAC Address Shows the device MAC Address Protocol version Shows the version of the Uti...

Страница 30: ...it indicates in red it means that there is new trap transmitted this is to remind us to view the trap Figure 8 Figure 8 When the View Trap button is clicked a Trap Information window will pop out it will show the trap information including the Symbol Time Device IP and the Event occurred Figure 9 Trap information The symbol represents the trap signal arise this symbol will disappear after you revi...

Страница 31: ...you can set the IP Address Subnet Mask Gateway Set Trap to Trap IP Address System name Location and DHCP setting In factory default the IP address of the DES 2110 will atomically assign from DHCP server DHCP enabled If your network has no DHCP server the DES 2110 will fail to get IP address and the IP address of DES 2110 will be assigned to default IP address of 192 168 0 1 and netmask is 255 255 ...

Страница 32: ...ed to change the password fill in the password needed in the dialog box and press Set button to precede the password change immediately Figure 11 Password Change Firmware Upgrade When the device has a new function there will be a new firmware to update the device use this function to update 24 ...

Страница 33: ...eb Management Utility have four main tabs File View Options and Help File TAB In the File TAB there are Monitor Save Monitor Save As Monitor Load and Exit Monitor Save To record the setting of the Monitor List to the default when you open the Web Management Utility next time it will auto load the default recorded setting Monitor Save As To record the setting of the Monitor List in appointed filena...

Страница 34: ...nitoring Help TAB In the Help TAB there is About function it will show out the version of the Web Management Utility Configuring the Switch using Web Browser All software functions of the DES 2110 can be managed configured and monitored via the embedded web based HTML interface The Switch can be managed from remote stations anywhere on the network through a standard browser such as Netscape Naviga...

Страница 35: ...ting Password setting Backup Setting Reset Setting Login to Web Management Before you configure this device note that when the Web Smart Switch is configured through an Ethernet connection make sure the manager PC must be set on same the IP network For example when the default IP address of the Web Smart Switch is 192 168 0 1 then the manager PC should be set at 192 168 0 x where x is a number bet...

Страница 36: ... Monitor List of the Web Management Utility to settle the device on the Web Browser When the following dialog page appears remain enter the default password admin and press Login to enter the main configuration window Figure 14 After entering the password the main page comes up the screen will display the device status 28 ...

Страница 37: ...Figure 15 Device Status 29 ...

Страница 38: ...you want to configure There are fifteen options Port Settings VLAN Settings Mirror Setting Spanning Tree Settings SNMP Settings Static MAC Settings IGMP Snooping Settings Device Status Statistic System Settings Trap Setting Password Setting Backup Setting and Reset Setting as shown in the Main Menu screen Figure 16 Setup menu 30 ...

Страница 39: ...ettings menu Figure 17 this page will show each port s status press the ID parameter to set each port s Speed Flow Control QoS priority and Link Status When you need to renew the posted information press the Refresh button The Link Status in the screen will show the connection speed and duplex mode else this dialog box will show down when the port is disconnected Figure 17 Port Configuration 31 ...

Страница 40: ...d or port disable selections Flow Control This setting determines whether or not the Switch will be handling flow control Set Flow Control to Enable for avoiding data transfer overflow Or it sets to Disable there is either no flow control or other hardware software management When the port is set to forced mode then the flow control will automatically set to Disable QoS In some ports that need to ...

Страница 41: ...N type if you change to the other VLAN mode the current VLAN setting will be erased Port based VLAN To add a VLAN group press Add Group button the new VLAN configuration window will pop out you can fill in the description in order to describe this VLAN Group check on the port to be a member to this VLAN Group and press Apply button to execute the setting Figure 19 VLAN Group Settings Figure 20 Add...

Страница 42: ...elect VID Table Setting press Add new VID to create new VID group from port 01 port 10 select Untag Port Tag Port or Not Member for each port To save the VID group press Apply button To remove the selected VID group select the VID group and press Remove the VID button To modify the VID group setting select the VID group and change the setting and press Apply button to save the settings Figure 22 8...

Страница 43: ... you select Port VLAN setting fill in each port s PVID value between 1 and 4094 Figure 23 802 1Q Port VID Setting Note If you change the VLAN mode to the other VLAN mode the current VLAN setting will be erased Figure 24 35 ...

Страница 44: ... source port from which to copy all packets and a sniffer port where those packets will be sent The selection of the sniffer mode is as follow TX transmit mode this mode will duplicate the data transmit from the source port and forward to the sniffer port RX receive mode this mode will duplicate the data that send to the source and forward to the sniffer port Both transmit and receive mode this mo...

Страница 45: ...Ultimately this difference results in faster detection of failed links and thus faster topology adjustment A draw back of 802 1d is this absence of immediate feedback from adjacent bridges Figure 26 Spanning Tree Setting STP Function To selecting enable or disable STP function on the Switch Bridge Priority This value between 0 and 65535 to specify the priority for forwarding packets The lower the ...

Страница 46: ...etween transmission of configuration messages by the root device thus stating that the Switch is still functioning A time between 1 and 10 seconds may be chosen with a default setting of 2 seconds Bridge Forward Delay The maximum amount of time in seconds that the root device will wait before changing states The user may choose a time between 4 and 30 seconds The default is 15 seconds Port Path Co...

Страница 47: ...he device These objects are defined in a Management Information Base MIB which provides a standard presentation of the information controlled by the on board SNMP agent SNMP defines both the format of the MIB specifications and the protocol used to access this information over the network The DES 2110 supports the SNMP versions 1 In SNMP v 1 user authentication is accomplished using community stri...

Страница 48: ...s a reboot someone accidentally turned OFF the Switch or less serious like a port status change The Switch generates traps and sends them to the trap recipient or network manager Typical traps include trap messages for Device boot up Authentication Failure Port status change and Abnormal transmit receive data packet error ...

Страница 49: ...addition to the standard MIB II the Switch also supports its own proprietary enterprise MIB as an extended Management Information Base The proprietary MIB may also be retrieved by specifying the MIB Object Identifier MIB values can be either read only or read write Enabled Disabled To selecting enable or disable SNMP function on the Switch SNMP Community Trap To configure the SNMP Community or SNM...

Страница 50: ...e read_only or read_write Press Apply button to execute the setting Figure 28 Add SNMP Community group Delete Group To delete previously defined SNMP Community group press Delete Group button the Delete SNMP Community configuration window will pop out checked the delete dialog box Press Apply to delete the selected SNMP Community Group Figure 29 Delete SNMP Community group 42 ...

Страница 51: ...y name and community enable Press Apply to save change of the SNMP Community Group Figure 30 Modify SNMP Community group Configure SNMP Trap Figure 31 Configure SNMP Trap Setting Trap authentication fail When checked the dialog box of the Trap authentication fail when fail to authentication the Switch will trap the authentication fail even to the SNMP host 43 ...

Страница 52: ...mote management station that will serve as the SNMP host for the Switch and checked the events selection to enabled selected event traps Figure 32 Add SNMP Trap Delete Trap To delete previously defined SNMP Trap press Delete Trap button the Delete SNMP Trap Delete configuration window will pop out checked the delete dialog box Press Apply to delete the selected SNMP Trap setting Figure 33 Delete S...

Страница 53: ...unction allows you to enable the Switch to forward the data packets to specific MAC address and specific port Only Static MAC function enabled ports will follow the Static MAC rule from the Static MAC list Enabled Disabled Selecting the enable or disable Static MAC function on the Switch Select Enabled to enabling the Static MAC function on the Switch the Switch s auto learning function will be di...

Страница 54: ...auto learning function will be disable check the dialog box of the Disable auto learning excluding uplink port and then check the dialog box of port numbers to enable the auto learning function of the port and the Switch will forward data following the Static MAC Address Table and the Switch s auto learn MAC address table to the specific port Figure 35 Configure Static MAC Setting Add Static MAC r...

Страница 55: ...ted Static MAC rule from the list Figure 37 Delete Static MAC IGMP Snooping Setting IGMP Snooping allows the Switch to read the Multicast Group IP address and the corresponding MAC address from IGMP packets that pass through the Switch The number of IGMP reports that were snooped is displayed in the Reports field Figure 38 IGMP Snooping Setting 47 ...

Страница 56: ...t group without the Switch receiving a host membership report The default is 260 seconds Router Timeout 1 16711450 Specifies the maximum amount of time a route can be a member of a multicast group without the Switch receiving a host membership report The default is 125 seconds Member Ports Checked specifies of ports as being connected to multicast enabled routers This will ensure that all packets ...

Страница 57: ...nt the device status on this screen it will show the System Status Port Status VLAN Setting Mirror Setting Spanning Tree status SNMP Setting and IGMP Setting Figure 39 Device Status Press Refresh when you need to renew the posted information 49 ...

Страница 58: ...tistic The Statistic Menu screen will show the status of each port packet count Figure 40 Device Statistics For Detail packet information click on the ID parameter as Figure 42 Figure 41 Port Statistics 50 ...

Страница 59: ... by using the System Name and the Location Name The Login Timeout is to set the idle time out for security issue when there is no action when running the Web Smart Utility and the time is up you must re login to Web Smart Utility before you set the Utility Fill up the IP address Subnet mask and Gateway for the device or enable DHCP get IP address from DHCP server Figure 42 System Setting 51 ...

Страница 60: ... Bootup a trap when booting up the system Illegal Login a trap when there is using a wrong password login and it will record from where the IP to be login Fiber Port Events Monitoring the Fiber port status Link Up Link Down a trap when there is linking status happens in fiber port Abnormal Receive Error a trap when there are receive data error in fiber port Abnormal Transmit Error a trap when ther...

Страница 61: ...port Abnormal 50 error packet count within 10 seconds Set Password Password is the invaluable tool for the manager to secure Web Management Switch use this function to change the password If you forget the password press the Reset button in the rear panel of the Switch the current setting includes VLAN Port Setting etc will be lost and the Switch will restore to the default setting Figure 44 Set P...

Страница 62: ... the recorded file Figure 45 Backup Setting Note when restoring a recorded file the current password will not be erased Reset Setting The Factory Reset button helps you to reset the device back to the default setting from the factory Be aware that the entire configuration will be reset the IP address of the device will be get from DHCP server factory default is DHCP enabled or got the default IP a...

Страница 63: ...Logout When press this function the web configuration will go back to first Login page Figure 47 Logout 55 ...

Страница 64: ...P IP Telnet protocol This section provides a reference for all of the commands contained in the CLI IP Address of the Switch The Switch IP address can be automatically set using DHCP protocols in which case the actual address assigned to the Switch must be known You can use the Web Management Utility to get or setting the IP address of the Switch Figure 48 Web Management Utility 56 ...

Страница 65: ...is telnet ip address Where ip address is the IP address you have assigned to the Switch When you telnet to the Switch it displays its login in message Figure 49 The DES 2110 console login At this point you can enter the password you have assigned to your print server The factory default password is admin The Switch will then display the telnet interface CLI command prompt 57 ...

Страница 66: ...er unwanted function that changes text case angle brackets Purpose Encloses a variable or value that must be specified Syntax show stp ports portlist Description This command displays the STP group of configuration on the Switch Example Command show stp ports 1 5 square brackets Purpose Encloses a required value or set of required arguments One value or argument can be specified Syntax show snmp c...

Страница 67: ...e above syntax sample you must specify either a community or host configuration to be show Example Command show snmp host braces Purpose Encloses an optional value or set of optional arguments Syntax reset config Description The command is used to restore the Switch s configuration to the default setting assigned from the factory Example Command reset config ...

Страница 68: ...ers show switch config system auto_logout value 3 30 config system_name system_name config location_name location_name reset config logout save Each command is listed in detail in the following sections show switch Purpose Used to display general information about the Switch Syntax show switch Description This command displays information about the Switch Parameters None ...

Страница 69: ...nfigure the auto log out timer of the Switch Syntax config system auto_logout value 3 30 Description This command is used to configure the auto log out timer of the Switch Parameters auto_logout value 3 30 A value is between 3 to 30 The telnet console will log out if there is no user input for 3 to 30 minutes 61 ...

Страница 70: ... system_name Purpose Used to configure the name for the Switch Syntax config system_name system_name Description The config system_name command configures the name of the Switch Parameters system_name A maximum of 20 characters is allowed Example usage To configure the Switch name for Sales SW 1 Figure 53 config system_name command 62 ...

Страница 71: ...location_name A maximum of 20 characters is allowed Example usage To configure the Switch location for Sales 6F Figure 54 config location_name command reset Purpose Used to reset the Switch to the factory default setting Syntax reset config Description The command is used to restore the Switch s configuration to the default setting assigned from the factory Parameters config All of the factory def...

Страница 72: ...ure 55 reset command logout Purpose Used to log out a user from the Switch s console Syntax logout Description This command terminates the current session on the Switch s console Parameters None Example usage To terminate the current telnet console session Figure 56 logout command 64 ...

Страница 73: ...ll be loaded into the Switch s memory each time the Switch is restarted Parameters None Example usage To save the Switch s current configuration to non volatile RAM Figure 57 save command Basic IP Commands The basic IP commands in the Command Line Interface CLI are listed along with the appropriate parameters in the following table Command Parameters config ipif ipaddress network address gw ipaddr...

Страница 74: ...work address IP address and netmask of the IP interface to created You can specify the address and mask information using traditional format for example Parameters 192 168 100 100 255 255 255 0 of in CIDR format 192 168 100 100 24 dhcp Allows the selection of the DHCP protocol for the assignment of an IP address to Switch s system IP address vlan_id Specific the 802 1Q VLAN ID to the Switch The ra...

Страница 75: ...s None Example usage To display IP interface settings Figure 59 show ipif command Switch Port Commands The switch port commands in the Command Line Interface CLI are listed along with the appropriate parameters in the following table Command Parameters config ports portlist all speed disable auto 10_half 10_full 100_half 100_full 1000_full flow_control enable disable qos normal high show ports por...

Страница 76: ...ws the user to adjust the speed for a port or range of ports The user has a choice of the following auto Enables auto negotiation for the specified range of ports 10 100 1000 Configures the speed in Mbps for the specified range of ports half full Configures the specified range of ports as either full duplex or half duplex flow_control enable disable Enable or disable flow control for the specified...

Страница 77: ...ose Used to display current configuration of a range of ports Syntax show ports portlist Description This command is used to display current configuration of a range of ports Parameters portlist Specifies a port or range of ports to be displayed 69 ...

Страница 78: ...Example usage To display the configuration of all ports on the switch Figure 61 show ports command 70 ...

Страница 79: ... 1 4094 add tagged untagged delete portlist show vlan vlan_name 8 tag vlanid 1 4094 enable port_based vlan disable port_based vlan enable 802 1q_based vlan Command Parameters disable 802 1q_based vlan config pvid portlist vlanid 1 4094 priority 0 7 Each command is listed in detail in the following sections create vlan Purpose Used to create a VLAN on the Switch Syntax create vlan vlan_name 8 tag v...

Страница 80: ... can be used vlanid 1 4094 The VLAN ID of the 802 1Q_based VLAN to be created Allowed values 1 4094 Example usage To create a Port_based VLAN sales VLAN group Figure 62 create vlan command port_based VLAN To create an 802 1Q_based VLAN tag 2 Figure 63 create vlan command 802 1q_based VLAN 72 ...

Страница 81: ...ously configured VLAN on the Switch Parameters vlan_name 8 The VLAN name of the Port_based VLAN you want to delete vlanid 1 4094 The VLAN ID of the 802 1Q_Based VLAN you want to delete Example usage To delete a Port_based VLAN sales VLAN group Figure 64 create vlan command port_based VLAN To delete an 802 1Q_based VLAN tag 10 Figure 65 delete vlan command 802 1q_based VLAN ...

Страница 82: ...t to add delete ports to from vlanid 1 4094 The VLAN ID of the 802 1Q_based VLAN you want to add delete ports to from tagged Specifies the additional ports as tagged untagged Specifies the additional ports as untagged add Entering the add parameter will add ports to the VLAN delete Delete ports from the specified VLAN portlist A port or range of ports to add to or delete from the specified VLAN Ex...

Страница 83: ...d delete VLAN group members port_based VLAN To add 1 through 3 as tagged ports to the VLAN tag 10 Figure 68 config vlan command add VLAN group members 802 1q_based VLAN To delete port 3 from the VLAN tag 10 Figure 69 config vlan command delete VLAN group members 802 1q_based VLAN 75 ...

Страница 84: ...pe to Port_based VLAN on the Switch Parameters None Example usage To switched the VLAN type to Port_based VLAN Figure 70 enable port_based vlan command disable port_based vlan Purpose Used to change the VLAN type to 802 1Q_based VLAN on the Switch Syntax disable port_based vlan Description This command allows you to change the VLAN type to 802 1Q_based VLAN on the Switch Parameters None ...

Страница 85: ...lan Purpose Used to change the VLAN type to 802 1Q_based VLAN on the Switch Syntax enable 802 1q_based vlan Description This command allows you to change the VLAN type to 802 1Q_based VLAN on the Switch Parameters None Example usage To switched the VLAN type to 802 1Q_based VLAN Figure 72 enable 802 1q_based vlan command 77 ...

Страница 86: ...ne Example usage To switched the VLAN type to Port_based VLAN Figure 73 disable 802 1q_based vlan command config pvid Purpose Used to configure the 802 1Q Port VLAN ID and priority Syntax config pvid portlist vlanid 1 4094 priority 0 7 Description This command allows you to configure the 802 1Q Port VLAN ID and priority Parameters portlist A port or range of ports to configure to the specified PVI...

Страница 87: ...802 1Q Port VLAN_ID Figure 74 config pvid command Port Mirroring Commands The port mirroring commands in the Command Line Interface CLI are listed along with the appropriate parameters in the following table Command Parameters config mirror port enable disable port source ports portlist rx tx both show mirror show mirror 79 ...

Страница 88: ...d must be operating at the same speed as the source port If the target port is operating at a lower speed the source port will be forced to drop its operating speed to match that the target port source ports The port or ports being mirrored This can not include the Target port config mirror port Description portlist This specifics a port or range of ports that will be mirrored That is the range of...

Страница 89: ...To disable Port Mirror function of the Switch Figure 76 config mirror port command disable port mirror function show mirror Purpose Used to show the current mirroring configuration on the Switch Syntax show mirror Description This command displays the current mirroring configuration on the Switch Parameters None 81 ...

Страница 90: ...listed along with the appropriate parameters in the following table Command Parameters config discovery trap_ip ipaddress ip_address vid vlan_id config discovery trap_event bootup illegal_login t_rx_err t_tx_err f_rx_err f_tx_err f_link_change delete discovery trap_event bootup illegal_login t_rx_err t_tx_err f_rx_err f_tx_err f_link_change show discovery trap 82 ...

Страница 91: ...p_address vid vlan_id Description The command is configure an IP address of the trap recipient of Web Management Utility to the Switch Parameters ip_address IP address of the Web Management Utility vlan_id Specific the 802 1Q VLAN ID of Web Management Utility The range is between 1 to 4094 Example usage To assigned IP address of the Web Configuration Utility to receive trap message Figure 78 confi...

Страница 92: ...h s boot up event illegal_login Enabled the Switch s illegal login event t_rx_err Enabled the Switch s twisted pair ports port 1 9 error receive data packets event t_tx_err Enabled the Switch s twisted pair ports port 1 9 error transmitting data packets event f_rx_err Enabled the Switch s fiber port port 10 error receive data packets event f_tx_err Enabled the Switch s fiber port port 10 error tra...

Страница 93: ...mand delete discovery trap_event Purpose Used to delete previously configured events of trap on the Switch Syntax delete discovery trap_event bootup illegal_login t_rx_err t_tx_err f_rx_rtt f_tx_err f_link_change Description The command is delete previously configured events of trap on the Switch 85 ...

Страница 94: ...witch s twisted pair ports port 1 9 error transmitting data packets event f_rx_err Disabled the Switch s fiber port port 10 error receive data packets event f_tx_err Disabled the Switch s fiber port port 10 error transmitting data packets event f_link_change Disabled the Switch s fiber port port 10 linking status change event Example usage To delete the event type from current event configuration ...

Страница 95: ...he command is display the configuration of the discovery trap on the Switch Parameters None Example usage To display discovery trap configuration Figure 81 show discovery trap command Spanning Tree Commands The spanning tree commands in the Command Line Interface CLI are listed along with the appropriate parameters in the following table ...

Страница 96: ...rtlist cost value 1 65535 priority value 0 255 show stp show stp ports portlist Each command is listed in detail in the following sections enable stp Purpose Used to enable STP on the Switch Syntax enable stp Description This command allows the Spanning Tree Protocol to be enabled on the Switch Parameters None Example usage To enable STP on the Switch Figure 82 enable stp command ...

Страница 97: ...alue 6 40 hellotime value 1 10 forwarddelay 4 30 priority value 1 65535 fbpdu enable disable Description This command is used to setup the Spanning Tree Protocol STP for the entire Switch Parameters maxage value 6 40 The value may be set to ensure that old information does not endlessly circulate through redundant paths in the network preventing the effective propagation of the new information Set...

Страница 98: ...configuration messages by the root device thus stating that the Switch is still functioning A time between 1 and 10 seconds may be chosen with a default setting of 2 seconds forwarddelay value 4 30 The maximum amount of time in seconds that the root device will wait before changing states The user may choose a time between 4 and 30 seconds The default is 15 seconds priority value 1 65535 Select a ...

Страница 99: ...portlist Specifies all ports or range of ports to be configured cost value 1 65535 This defines a metric that indicates the relative cost of forwarding packets to specified port list The value between 1 and 65535 to determine the cost The lower the number the greater the probability the port will be chosen to forward packets The default value is 10 priority value 0 255 Select a value between 0 and...

Страница 100: ...10 priority of 100 for ports 1 5 Figure 85 config stp ports command show stp Purpose Used to display the Switch s current STP configuration Syntax show stp Description This command displays the Switch s current STP configuration Parameters None 92 ...

Страница 101: ...how stp ports Purpose Used to display the Switch s current STP group of ports configuration on the Switch Syntax show stp ports portlist Description This command displays the STP group of configuration on the Switch Parameters portlist Specifies a port or range of ports to be viewed 93 ...

Страница 102: ...Example usage To display the STP status of port on the Switch Figure 87 show stp ports command 94 ...

Страница 103: ...ty_string delete snmp host ipaddress trap_community community_string show snmp host enable snmp traps disable snmp traps Each command is listed in detail in the following sections create snmp community Purpose Used to create an SNMP community string to define the relationship between the SNMP manager and an agent The community string acts like a password to permit access to the agent on the Switch...

Страница 104: ...like a password to give remote SNMP managers access to MIB objects in the Switch s SNMP agent read_only Specifies that SNMP community members using the community string created with this command can only read the contents of the MIBs on the Switch read_write Specifies that SNMP community members using the community string created with this command can only read from and write to the contents of th...

Страница 105: ...e snmp community community_string 20 read_only read_write Description This command is used to remove a previously defined SNMP community string from the Switch Parameters community_string 20 Specifies which previously created SNMP community to be delete read_only Specifies which previously created SNMP community of read_only to be delete read_write Specifies which previously created SNMP community...

Страница 106: ...Switch Example usage To display the currently entered SNMP community strings Figure 90 show snmp community command create snmp host Purpose Used to create a recipient of SNMP traps generated by the Switch s SNMP agent Syntax create snmp host ipaddress vid vlan_id trap_community community_string Description This command creates a recipient of SNMP traps generated by the Switch s SNMP agent 98 ...

Страница 107: ... a remote SNMP manager to access the Switch s SNMP agent Example usage To create an SNMP host to receive SNMP messages Figure 91 create snmp host command show snmp host Purpose Used to display the recipient of SNMP traps generated by the Switch s SNMP agent Syntax show snmp host Description This command is used to display the IP addresses and configuration information of remote SNMP managers that ...

Страница 108: ...gure 92 show snmp host command enable snmp traps Purpose Used to enable SNMP trap support on the Switch Syntax enable snmp traps Description This command is used to enable SNMP trap support on the Switch Parameters None Example usage To enable SNMP trap support on the Switch 100 ...

Страница 109: ... Used to disable SNMP trap support on the Switch Syntax disable snmp traps Description This command is used to disable SNMP trap support on the Switch Parameters None Example usage To disable SNMP trap support on the Switch Figure 94 disable snmp traps command 101 ...

Страница 110: ...ted in detail in the following sections config router_ports Purpose Used to configure ports as router ports Syntax config router_ports add delete portlist Description This command allows you to designate a range of ports as being connected to multicast enabled routers This will ensure that all packets with such a router as its destination will reach the multicast enabled router regardless of proto...

Страница 111: ...enable igmp snooping Purpose Used to enable IGMP snooping on the Switch Syntax enable igmp snooping forward_mcrouter_only Description This command allows you to enable IGMP snooping on the Switch If forward_mcrouter_only is specified the Switch will only forward all multicast traffic to the multicast router only Otherwise the Switch forwards all multicast traffic to any IP router Parameters None 1...

Страница 112: ...command disable igmp snooping Purpose Used to disable IGMP snooping on the Switch Syntax disable igmp snooping Description This command disables IGMP snooping on the Switch Parameters None Example usage To disable IGMP snooping on the Switch Figure 98 disable igmp snooping command 104 ...

Страница 113: ...y configured router ports on the Switch Parameters None Example usage To display the router ports Figure 99 show router_ports command show igmp_snooping group Purpose Used to display the current IGMP snooping configuration on the Switch Syntax show igmp_snooping group Description This command will display the current IGMP setup currently configured on the Switch Parameters None ...

Страница 114: ...n This command allows you to configure IGMP snooping on the Switch Parameters host_timeout sec 1 16711450 Specifies the maximum amount of time a host can be a member of a multicast group without the Switch receiving a host membership report The default is 260 seconds router_timeout sec 1 16711450 Specifies the maximum amount of time a route can be a member of a multicast group without the Switch r...

Страница 115: ...Example usage To configure IGMP snooping Figure 101 config igmp_snooping command 107 ...

Страница 116: ...CD Data Transfer Rate Ethernet 10Mbps half duplex 20Mbps full duplex Fast Ethernet 100Mbps half duplex 200Mbps full duplex Gigabit Ethernet 2000Mbps full duplex Topology Star Network Cables Ethernet 2 pair UTP Cat 3 4 5 EIA TIA 568 STP Fast Ethernet 2 pair UTP Cat 5 EIA TIA 568 STP Gigabit Ethernet 4 pair UTP Cat 5 EIA TIA 568 STP Number of Ports 8 x 10 100BASE TX Auto MDIX UTP ports 1 x 1000BASE ...

Страница 117: ... 10 90 RH non condensing Dimensions 280 mm x 180 mm x 44 mm EMI FCC Class A CE Mark Class A VCCI Class A Performance Transmission Method Store and forward RAM Buffer 256 Kbytes per device Filtering Address Table 4K MAC address per device Packet Filtering Forwarding Rate Ethernet 14 880pps Fast Ethernet 148 800pps Gigabit Ethernet 1 488 000pps MAC Address Learning Self learning Auto aging ...

Страница 118: ...ützen 6 Bei der Aufstellung des Gerätes ist auf sichern Stand zu achten Ein Kippen oder Fallen könnte Verletzungen hervorrufen Verwenden Sie nur sichere Standorte und beachten Sie die Aufstellhinweise des Herstellers 7 Die Belüftungsöffnungen dienen zur Luftzirkulation die das Gerät vor Überhitzung schützt Sorgen Sie dafür daß diese Öffnungen nicht abgedeckt werden 8 Beachten Sie beim Anschluß an ...

Страница 119: ...gedrungen c Das Gerät war Feuchtigkeit ausgesetzt d Wenn das Gerät nicht der Bedienungsanleitung ensprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Gerät ist gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 16 Bei Reparaturen dürfen nur Orginalersatzteile bzw den Orginalteilen entsprechende Teile v...

Страница 120: ... NOT EXIST OR WAS CAUSED BY THE CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WILL D LINK BE LIABLE FOR ANY DAMAGES INCLUDING LOSS OF DATA LOSS OF PROFITS COST OF COVER OR OTHER INCIDENTAL CONSEQ...

Страница 121: ... pursuant to this warranty shall have a warranty period of not less than 90 days from date of such repair irrespective of any earlier expiration of original warranty period When D Link provides replacement then the defective product becomes the property of D Link Warranty service may be obtained by contacting a D Link office within the applicable warranty period and requesting a Return Material Au...

Страница 122: ... with the applicable product documentation provided by D Link with such software product for a period of ninety 90 days from the date of purchase from D Link or its Authorized Reseller D Link warrants the magnetic media on which D Link provides its software product against failure during the same warranty period This warranty applies to purchased software and to replacement software provided by D ...

Страница 123: ...o provide compatibility when there is fault in the third party hardware or software D Link makes no warranty that operation of its software products will be uninterrupted or absolutely error free and no warranty that all defects in the software product within or without the scope of D Link s applicable product documentation will be corrected ...

Страница 124: ...mpaq 486 Product installed in computer serial No Applies to adapters only Product was purchased from Reseller s name ______________________________________________________________________________ Telephone _______________________________________ Fax ________________________________________ Reseller s full address _________________________________________________________________________ ___________...

Страница 125: ... used on your network Desktop publishing Spreadsheet Word processing CAD CAM Database management Accounting Others_____________________ 8 What category best describes your company Aerospace Engineering Education Finance Hospital Legal Insurance Real Estate Manufacturing Retail Chainstore Wholesale Government Transportation Utilities Communication VAR System house company Other_____________________...

Страница 126: ......