NO.

Name

Def.

Valid

A B

Description

2 Basic Set 

Level

0xFF

All

 

Setting the BASIC command value to 
turn on the light. The 0xFF(-1) means 
turn on the light. For dimmer 
equipment 1 to 100 means the light 
strength.
0 means turn off the light.

3

(*)

PIR 

Sensitivity

80

0 ~

99

 

PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected 
long distance, but if there is more 
noise signal in the environment, it will 
re-trigger too frequency.

4 Light 

Threshold

99

0 ~

100

 

Setting the illumination threshold to 
turn on the light. When the event 
triggered and the environment 
illumination lower then the threshold, 
the device will turn on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination 
detected function. And always turn on 
the light.

Notice:

 In none test mode, only the 

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

NO.

Name

Def.

Valid

A B

Description

NO.

Name

Def.

Valid

A B

Description

5

(*)

Operation

Mode

0

All

Operation mode. Using bit to control.

0

 

Bit0

: Reserve.

0

 

Bit1

: 1 means test mode, 

        0 means normal mode.

Notice:

This bit only effect by the DIP Switch 
setting to “customer mode”, otherwise 
it decides by DIP Switch setting to Test
or Normal Mode.

0

 

Bit2

: Disable the door/window 

function.  (1:Disable, 0:Enable)

0

 

Bit3

: Setting the temperature scale.

  0: 

Fahrenheit

, 1:Celsius

0

 

Bit4

: Disable the illumination report 

after event triggered.  (1:Disable, 
0:Enable)

0

 

Bit5

: Disable the temperature report 

after event triggered.  (1:Disable, 
0:Enable)

0

 

Bit6

: Reserve.

0

 

Bit7: 

Disable the back key release 

into test mode.  (1:Disable, 
0:Enable)

NO.

Name

Def.

Valid

A B

Description

9

Содержание DCH-Z110

Страница 1: ...rs regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communi...

Страница 2: ...groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is for light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM netwo...

Страница 3: ...hen the PIR motion detected or the door window state changed the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Note To disable this functionality by setting the configuration N0 5 bit5 to 1 Temperature differential report This function default is enabled to disable this function by setting the configuration NO 21 to 0 In the d...

Страница 4: ...ult It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timin...

Страница 5: ... the sensor function when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the tempera...

Страница 6: ...6 ...

Страница 7: ...e the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm for DCH Z120 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the sour...

Страница 8: ...einafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and dec...

Страница 9: ... the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Valid A B Description NO Name Def Valid A B Description 5 Operation Mode 0 All Operation mode Using bit to control 0 Bit0 Reserve 0...

Страница 10: ... turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def Valid A B Description NO Name Def Valid A B Description 7 Customer Function 4 A...

Страница 11: ...means turn off auto report door window state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B Description NO Name Def Valid A B Description 12 Auto Report Illumination Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report illumination The default value is 12 The tick time can setting by the configuration No 2...

Страница 12: ...ASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium...

Страница 13: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modif...

Отзывы: