NO.
Name
Def.
Valid
A B
Description
6
(*)
Mult-
Sensor
Function
Switch
4
All
Multisensor function switch. Using bit
to control.
0
Bit0
: Disable magnetic integrate
illumination to turn ON the lighting
nodes in the association group 2.
(1:Disable, 0:Enable)
0
Bit1
: Disable PIR integrate
Illumination to turn ON the lighting
nodes in the association group 2.
(1:Disable, 0:Enable)
1
Bit2
: Disable magnetic integrate PIR
to turn ON the lighting nodes in the
association group 2. (1:Disable,
0:Enable) (Default is Disable)
0
Bit3
: When Bit2 is 0 (Enable), Are the
device and the lighting in the same
room?
0: In the same room(Default),
1: In the different room.
Notice
: If this bit is 1, it is
recommended also set the Bit1 to 1,
cause the PIR triggered, doesn't
mean the people in that room.
0
Bit4
: Disable delay 5 seconds to turn
off the light, when door/window
closed. (1:Disable, 0:Enable)
0
Bit5
: Disable auto turn off the light,
after door/window opened to turn on
the light. (1:Disable, 0:Enable)
Notice:
If bit2 is zero, this setting is
useless.
Notice:
If the configuration No.9 is
zero, this setting is useless.
0
Bit6
: Reserve.
0
Bit7
: Reserve.
NO.
Name
Def.
Valid
A B
Description
NO.
Name
Def.
Valid
A B
Description
7
(*)
Customer
Function
4
All
Customer function switch, using bit
control.
0
Bit0
: Reserve.
0
Bit1
: Enable sending motion OFF
report. (0:Disable, 1:Enable)
Note
: Depends on the Bit4,
0: Report Notification CC,
Type: 0x07, Event: 0xFE
1: Sensor Binary Report,
Type: 0x0C, Value: 0x00
1
Bit2
: Enable PIR super sensitivity
mode. (0:Disable, 1:Enable)
0
Bit3
: Disable send out BASIC OFF
after door closed. (1:Disable,
0:Enable)
0
Bit4
: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5
: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
0
Bit6
: Disable to report battery state
when the device triggered. (1:Disable,
10