background image

This function default is disabled, to enable this function by setting the

configuration NO.22 not to zero.

Enable  this  functionality,  the device  will  measure  the  illumination  in

every one minute. And if the illumination is changed to plus or minus

the value (setting by the configuration NO.22), the device will report

illumination information to the nodes in the group 1.

Caution 1

Enable this function will reduce the battery life about 15% 

~ 20%. And another issue is setting the differential value too small, it 

will cause report too frequency, shorter the battery life more.

Propose the setting differential value should not small than 10.

Caution 2

:

 If the configuration No.4 is setting to 0 or 100, this 

functionality is useless.

Caution 3

:

 Enable this functionality, it will cause the PIR Motion to 

disable detection when the illumination measurement. In other words, 

The PIR motion will blind one second in every one minute.

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 10.

Low   battery   report:   When   the   battery   level   is   too   low,   every   30

minutes will report once.

Door/window state report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 11.

Illumination level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 12.

Temperature report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 13.

Notice

:  The configuration NO. 10, 11, 12 and 13 could be setting to

zero to disable the auto report. And the configuration NO. 20 could

change the tick interval, the default value is 30, if setting to 1, that

means the minimum auto report interval will be one minute. And please

notice if setting this value to zero, that means disable all of the timing

report except the low battery detection.

Power Up Procedure

* Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* PIR Warm Up

When   the   device   power   on,   the   PIR   need   to   warm   up   before   the

operation. The warm up time about 1 minute, the LED will flash in

every 2 seconds. After finish the procedure the LED will light ON three

times.

* NWI

When the device power on, the device will check is it already adding to

the network? If doesn't, it will auto start the NWI mode. The LED will

flash in every second and continue 30 seconds. Until timeout or the

device successful to inclusion by controller. The use can presses the

tamper key 3 times to abort the NWI mode.

* Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Over The Air (OTA) Firmware Update

The device supports the Z-Wave firmware update via OTA.

Before starting the procedure, please remove the front cover of the

device. Otherwise the hardware check will be failed.

Let the controller into the firmware update mode, and then press the

front tamper key once to start the update.

4

Содержание DCH-Z110

Страница 1: ...rs regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communi...

Страница 2: ...groups The group 1 is for receiving the report message like triggered event temperature illumination etc The group 2 is for light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM netwo...

Страница 3: ...hen the PIR motion detected or the door window state changed the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Sensor Type Temperature 0x01 Note To disable this functionality by setting the configuration N0 5 bit5 to 1 Temperature differential report This function default is enabled to disable this function by setting the configuration NO 21 to 0 In the d...

Страница 4: ...ult It could be changed by setting the configuration NO 13 Notice The configuration NO 10 11 12 and 13 could be setting to zero to disable the auto report And the configuration NO 20 could change the tick interval the default value is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timin...

Страница 5: ... the sensor function when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the tempera...

Страница 6: ...6 ...

Страница 7: ...e the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm for DCH Z120 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the sour...

Страница 8: ...einafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and dec...

Страница 9: ... the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Valid A B Description NO Name Def Valid A B Description 5 Operation Mode 0 All Operation mode Using bit to control 0 Bit0 Reserve 0...

Страница 10: ... turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable Notice If bit2 is zero this setting is useless Notice If the configuration No 9 is zero this setting is useless 0 Bit6 Reserve 0 Bit7 Reserve NO Name Def Valid A B Description NO Name Def Valid A B Description 7 Customer Function 4 A...

Страница 11: ...means turn off auto report door window state The default value is 12 The tick time can setting by the configuration No 20 NO Name Def Valid A B Description NO Name Def Valid A B Description 12 Auto Report Illumination Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report illumination The default value is 12 The tick time can setting by the configuration No 2...

Страница 12: ...ASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Specifications Power by CR123A lithium...

Страница 13: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modif...

Отзывы: