background image

* Tamper Report:

Both the 2 tamper keys are pressed over 5 seconds. The device will

into the alarm state. In that state, if any one of the tamper keys be

released, the device will unsolicited to send the report to the nodes in

the group 1.

Notification Report (V4)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)

Sensor Value: 0xFF

* Temperature Report:

When the PIR motion detected tate changed, the device will unsolicited

to send the “Sensor Multilevel Report” to the nodes in the group 1.

Caution 1

:

 Enable this functionality, it will cause the PIR Motion to 

disable detection when the temperature measurement. In other words,

The PIR motion will blind one second in every one minute.

 

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Notice

:  The configuration NO. 10, 11, 12 and 13 could be setting to

zero to disable the auto report. And the configuration NO. 20 could

change the tick interval, the default value is 30, if setting to 1, that

means the minimum auto report interval will be one minute. And please

notice if setting this value to zero, that means disable all of the timing

report except the low battery detection.

Power Up Procedure

* Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* PIR Warm Up

When   the   device   power   on,   the   PIR   need   to   warm   up   before   the

operation. The warm up time about 1 minute, the LED will flash in

every 2 seconds. After finish the procedure the LED will light ON three

times.

* NWI

When the device power on, the device will check is it already adding to

the network? If doesn't, it will auto start the NWI mode. The LED will

flash in every second and continue 30 seconds. Until timeout or the

device successful to inclusion by controller. The use can presses the

tamper key 3 times to abort the NWI mode.

* Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Security Network

The device support the security function. When the device included

with a security controller, the device will auto switch to the security

mode. In the security mode, the follow commands need using Security

3

All manuals and user guides at all-guides.com

Содержание DCH-122

Страница 1: ...ow Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network In the first time add the dev...

Страница 2: ... to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake Up Notification message to the network and w...

Страница 3: ...lue is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flas...

Страница 4: ...delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Normal Mode it according to the setting of the configuration NO 8 Notice When the tamper key of the back side is released the device always in the Test Mode no matter the DIP switch setting Battery Installation When the ...

Страница 5: ...ing The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you can remove tape A and mounting the sensor by using tape B The tamper key will pressed and let the sensor enter no...

Страница 6: ...ns turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Vali d A B C Description 5 Operation Mode 0 All Operation mode Using bit to control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 1 means test mo...

Страница 7: ...f Vali d A B C Description received the trigger signal too frequently Also can save the battery energy Notice If this value bigger than the configuration setting NO 9 There is a period after the light turned off and the PIR not start detecting 9 Turn Off Light Time 4 0 127 After turn on the lighting setting the delay time to turn off the lighting when the PIR motion is not detected 8 seconds per t...

Страница 8: ... use only Specifications subject to change without notice due to continuing product improvement FCC ID KA2CHZ122A1 IC ID 4216A CHZ122A1 Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable re...

Страница 9: ...his device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any o...

Отзывы: