background image

of   the   device.   The   device   will   auto   start   the   NWI   (Network   Wide

Inclusion) mode. And it should be included in 5 seconds. You will see

the LED light ON one second.

2. Let the controller associate with the device into the first group, any

light switch that intend to be turned on when the device trig please

associate with the device into the second group.

3. In the accessory pack. There are two type of double coated tape,

one is thicker (hereinafter referred to as A tape)  and another is thinner

(hereinafter referred to as B tape), you can use A tape for the test at

the beginning. The right way for A tape installation is stick it to the

position below tamper key. The thicker tape won't let the tamper key

pressed,   so   the   sensor   will   enter   the   test   mode,   You   may   test   if

installed position is good or not by this way.

After finish the test and decide to fix, then you can remove tape A, and

mounting the sensor by using tape B. The tamper key will pressed and

let the sensor enter normal mode.

Z-Wave Configuration Settings

Notice:

 

* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the setting
still   keep,   don't   reset   to   factory   default.   Unless   the   user   execute   the
“RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect. 

5

All manuals and user guides at all-guides.com

Содержание DCH-122

Страница 1: ...ow Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network In the first time add the dev...

Страница 2: ... to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake Up Notification message to the network and w...

Страница 3: ...lue is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flas...

Страница 4: ...delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Normal Mode it according to the setting of the configuration NO 8 Notice When the tamper key of the back side is released the device always in the Test Mode no matter the DIP switch setting Battery Installation When the ...

Страница 5: ...ing The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you can remove tape A and mounting the sensor by using tape B The tamper key will pressed and let the sensor enter no...

Страница 6: ...ns turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Vali d A B C Description 5 Operation Mode 0 All Operation mode Using bit to control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 1 means test mo...

Страница 7: ...f Vali d A B C Description received the trigger signal too frequently Also can save the battery energy Notice If this value bigger than the configuration setting NO 9 There is a period after the light turned off and the PIR not start detecting 9 Turn Off Light Time 4 0 127 After turn on the lighting setting the delay time to turn off the lighting when the PIR motion is not detected 8 seconds per t...

Страница 8: ... use only Specifications subject to change without notice due to continuing product improvement FCC ID KA2CHZ122A1 IC ID 4216A CHZ122A1 Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable re...

Страница 9: ...his device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any o...

Отзывы: