NO
.
Name
Def.
Vali
d
A B C
Description
the range is from 0x00 ~ 0xFF.
0
Bit0
: Reserve.
0
Bit1
: Enable sending motion OFF
report. (0:Disable, 1:Enable)
Note
: Depends on the Bit4,
0: Report Notification CC,
Type: 0x07, Event: 0xFE
1: Sensor Binary Report,
Type: 0x0C, Value: 0x00
1
Bit2
: Enable PIR super sensitivity
mode. (0:Disable, 1:Enable)
0
Bit3
: Disable send out BASIC OFF
after door closed. (1:Disable,
0:Enable)
0
Bit4
: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5
: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
0
Bit6
: Disable to report battery state
when the device triggered. (1:Disable,
0:Enable)
0
Bit7
: Reserve.
8 PIR Re-
Detect
Interval
Time
3
1 ~
127
In the normal mode, after the PIR
motion detected, setting the re-detect
time. 8 seconds per tick, default tick is
3 (24 seconds).
Setting the suitable value to prevent
NO
.
Name
Def.
Vali
d
A B C
Description
received the trigger signal too
frequently. Also can save the battery
energy.
Notice:
If this value bigger than the
configuration setting
NO. 9. There is a
period after the light turned off and
the PIR not start detecting.
9
Turn Off
Light
Time
4
0 ~
127
After turn on the lighting, setting the
delay time to turn off the lighting
when the PIR motion is not detected.
8 seconds per tick, default tick is 4 (32
seconds).
0 means never send turn off light
command.
10
Auto
Report
Battery
Time
12
0 ~
127
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
20
Auto Report
Tick
Interval
30
0 ~
0xFF
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.11,
No.12 and No.13.
The unit is 1 minute.
Caution1
:
Setting to
0
means turn
off all auto report function.
Caution2:
The value is unsigned
byte, the range is from 0x00 ~ 0xFF.