background image

CE Mark Warning 

This is a Class B product. In a domestic environment, this product may cause 
radio interference, in which case the user may be required to take adequate 
measures  

Warnung! 

Dies ist in Produkt der Klasse B. Im Wohnbereich kann dieses Produkt 
Funkstoerungen verursachen. In diesem Fall kann vom Benutzer verlangt 
werden, angemessene Massnahmen zu ergreifen. 

Advertencia de Marca de la CE 

Este es un producto de Clase B. En un entorno doméstico, puede causar 
interferencias de radio, en cuyo case, puede requerirse al usuario para que 
adopte las medidas adecuadas. 

Attention! 

Ceci est un produit de classe B. Dans un environnement domestique, ce produit 
pourrait causer des interférences radio, auquel cas l`utilisateur devrait prendre 
les mesures adéquates. 

Attenzione! 

Il presente prodotto appartiene alla classe B. Se utilizzato in ambiente 
domestico il prodotto può causare interferenze radio, nel cui caso è possibile 
che l`utente debba assumere provvedimenti adeguati. 

FCC Warning 

This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of 
the following measures: 
-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and receiver. 
-Connect the equipment into an outlet on a circuit different from that to which 
the receiver is connected. 
-Consult the dealer or an experienced radio/ TV technician for help.

Содержание AirPremier DWL-1800

Страница 1: ...rocedures The Base Unit Station DWL 1800B is a required product in all installations wether PtP or PtMP architecture the remote stations can t communicate to each others without DWL 1800B Outdoor units and antennas should be installed ONLY by experienced installers who are familiar with local building and safety codes and wherever applicable are licensed by the appropriate authorities Failure to d...

Страница 2: ... tighten the nut Make sure that the external jack of the cable is well inside the service box to guarantee a good sealing Route the cable to the location selected for the Indoor unit Preparing the Indoor to Outdoor Cable The Indoor to Outdoor cable provides pin to pin connection on both sides It is supplied open ended to allow the installer to conveniently route the cable through the service box o...

Страница 3: ...ge combination change antenna height and verify RF cables connections Verifying Correct Operation To verify proper operation of the Outdoor unit view the LED indicators located on the bottom panel of the unit as shown in the following table Outdoor Unit LEDs Name Description Functionality WLAN Wireless Link Indicator Blinking Green Data received or transmitted on wireless link Blinking rate is low...

Страница 4: ...he D Link AirPremier DWL 1800 wireless network will be up and running immediately If you are content with the default settings of the DWL 1800B DWL 1800R units you can stop right here It is more likely however that you want to assign different radio frequencies to each DWL 1800B DWL 1800R or impose some restrictions on the use of your wireless network 2 To be able to manage the DWL 1800B DWL 1800R...

Страница 5: ...rimp the connector Make sure to do the following a Remove as smaller length as possible of the external jacket to verify that the external jacket will be well inside the service box when connected to the Outdoor unit to ensure good sealing b Take back the shield drain wire before inserting the cable into the RJ 45 connector to ensure a good connection with the connector s shield after crimping Con...

Страница 6: ...s guide should arise checking the Ethernet and WLAN counters may help If the problem persists please feel free to contact your local distributor or the D Link Technical Support Department Troubleshooting Guide Problem and Indication Possible Cause Corrective Action No power to unit Power LED is off Power cord is not properly connected Verify power cord is properly connected to the DWL 1800 unit an...

Страница 7: ...tenna height Wireless link established but there is no Ethernet activity DWL 1800B and DWL 1800R units 1 Ethernet hub port or UTP cable is faulty 2 Ethernet port in unit is faulty 1 The DWL 1800R is associated to a DWL 1800B unit that is not connected correctly to the LAN 1 Check that the LINK LED is lighted Green If this is not the case the port is inactive Try another port on the hub or another ...

Страница 8: ...er of associations is 128 What is the practical limit to the number of DWL 1800R units per DWL 1800B And what performance can I expect for a multi point link This depends upon average throughput expectations All clients would have the maximum throughput available for burst traffic however the overall average would depend on the utilization of the network For example in a heavily utilized network n...

Страница 9: ...ructure Each unit is assigned to one of the non overlapping channels 1 6 or 11 Can a Frequency Hopping network operate in the same area as the D Link Air Premier DWL 1800 Yes but in a collocated network both products will suffer some a decrease in performance The degree of performance loss depends on network utilization For example the higher the utilization of the Frequency Hopping network the hi...

Страница 10: ...the old firmware version is overwritten with the new version on the new power on cycle Can D Link Air Premier DWL 1800 firmware be downgraded Yes an earlier version of firmware can overwrite a newer version Can the previous version of firmware be kept The previous version of firmware cannot be kept on the DWL 1800 itself but can be stored on your PC and loaded if needed Configuration Can the regul...

Страница 11: ...SNMP What installation and site survey tools are available for DWL 1800 DWL 1800 The DWL 1800 comes with a Windows based manager utility With this utility you can configure link parameters and monitor signal quality and RSSI received signal strength indication Optimizing antenna alignment is done using the signal quality and RSSI display Any computer on the network can use this utility to manage t...

Страница 12: ...le che l utente debba assumere provvedimenti adeguati FCC Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not ins...

Страница 13: ...lant et utilisant les produits réseaux sans fils de la gamme proposée par D Link vous vous engagez donc à respecter cette réglementation et à n utiliser que ces 4 canaux WARNING The Decision N 01 480 taken by ART Autorité de Régulation de Télécommunications on May 23 2001 authorizes the utilisation of a part of the 2400 2483 5MHz band for Radio Local Area Network RLAN in France Only the 2446 5 248...

Страница 14: ...99 5 EC The following importer manufacturer is responsible for this declaration Company Name D Link Corporation Company Address No 8 Li shing Road VII Science based Industrial Park Hsinchu Taiwan R O C Telephone 886 3 563 6666 Facsimile 886 3 578 1861 Person is responsible for marking this declaration Sam Liang President Name Full Name Position Title August 7 2002 Date Legal Signature ...

Страница 15: ...ree REPAIR LINE 00800 7250 8000 E MAIL info dlink de URL www dlink de IBERIA D LINK IBERIA Gran Via de Carlos III 84 3 Edificio Trade 08028 BARCELONA TEL 34 93 4090770 FAX 34 93 4910795 E MAIL info dlinkiberia es URL www dlinkiberia es INDIA D LINK INDIA Plot No 5 Kurla Bandra Complex Road Off Cst Road Santacruz E Bombay 400 098 India TEL 91 22 652 6696 FAX 91 22 652 8914 E MAIL service dlink indi...

Отзывы: