English
English
99.831.10 1.2/02/16
99.831.10 1.2/02/16
6/16
7/16
VCD 204 -K
VCD 204 -K
Type
VCD 204-K
Power supply
230 V AC / +10...-15 % / 50 ... 60 Hz
Power consumption
10 W / 15 VA
Nominal force
200 N
Nominal locking force
approx. 2000 N (Excluding bracket)
Service life
>20 000 double strokes
Duty cycle
30 % (With cycle time 10 minutes)
Housing
Zinc-diecasting, powdercoated
Ingress protection
IP 30
Temp. range
0 ... +60 °C
Emission sound pressure level
LpA ≤ 70 dB(A)
Nominal stroke length*
See type plate
Additional functions
Closing edge protection activated (3 stroke repeatings),
Locking relief activted
* Adjustable with magnet
Stroke limiting with magnets
Closing edge protection
In the "CLOSE" direction the drive has an active
protection for the main closing edge. If there is an
overload in the closing ranges 3 and 2, the drive runs
"OPEN" for 20 seconds, then "CLOSE" again. If
closing is not possible after three attempts, the drive
remains in this position.
In addition, the drive is equipped with passive
protection. The closing speed in closing range 2 and
1 is reduced to 5 mm/s.
Significantly greater forces can be
exerted at the secondary closing edges.
Danger of crushing hands and fingers!
Main closing edge
Beside closing edge
Beside -
closing edge
Voltage must continue to
be applied to the drive when
moving in the “CLOSE”
direction.
Hold the magnet next
to the drive as shown in the
diagramme (2 sec.) until you hear
a pulsating ton >
The
drive
is
now
in
learning
mode
.
The
magnet
can
now
be
removed
and
the
drive
no
longer
has
to
be
under
voltage
.
Close drive.
1
Allow the drive to run
“OPEN” until you reach the
required stroke.
If the stroke is set incorrectly,
the procedure is accidentally
interrupted or the drive
continues to the full stroke
length, please return to point 1
and start again.
STOP
3
appr
.100 mm
learning mode
appr. 2 sec.
2
Electrical devices, accessories, batteries and packa-
ging should be sorted for environmental-friendly
recycling. Do not dispose electrical devices and
batteries into household waste!
Only for EC countries:
According the European Guideline 2012/19/EU for
waste electrical and electronic equipment and its
implementation into national right, electrcal devices
that are no longer usable must be collected separa-
tely and disposed of in an environmentally correct
manner.
Disposal
Declaration of Conformity
We declare under our sole responsibility that the
product described under “Technical Data” is in
conformity with the following directives:
2014/30/EU, 2014/35/EU
Technical file at:
D+H Mechatronic AG, D-22949 Ammersbek
Dirk Dingfelder
Maik Schmees
Member of the Board
Authorized signatory, Technical Director
24.02.2016
All approx. 20 % switch-off reserve (temporary)
Closure Ranges
~6 mm/s
150 N
(Safety cut-off force)
5 mm/s
150 N
77 mm
~6 mm/s
200 N
23 mm
Running speed and forces
Technical data