Connection Examples
Connection with line derivation:
supply wires
Mot a / Mot b
derive off in par-
allel,
monitoring
will be looped through all
cables up to group end.
Example 1:
1 lane
Simple installation, but unfavourable for
voltage drop: All drives on one line.
Example 2:
2 lanes
Control panel in centre, one side wired as
derivation, the other as terminal line.
Observe 4 wires for derivation!
Example 3:
2 lanes on one side
Derivation and terminal lines in same
direction; number of drives vary according
to line lengths.
Observe 4 wires for derivation!
Example 4:
3 lanes
3 line lanes have been provided due to
extremely long distances: 2 line lanes with
3 drives each on 75 m line as derivation,
and 1 line lane with 2 drives on 200 m line.
Observe 4 wires for derivation!