background image

Gebra

uchsan

leitu

ng

99.821.70 3.5/01/12

housing

transformer

rail

cable duct

cable ducts

motherboard with rectifier card
and power supply plug-in unit

keys

Smoke Vent Control Panel RZN 43xx-E

Installation

Safety system protects human life and material assets!

A specialist company authorised by the manufacturer should carry out connection, installation and annual

service.

Green control diodes in the buttons must be alight all the time, otherwise see "Trouble shooting".

Repair power failure immediately. Emergency power supply available for 72 hours.

Instruction for use

i n s t r u c t i o n

f o r

u s e

Smoke vent control book

Fig.: RZN 43xx-E6

D+H service and sales partners

Installation and operation

Safety in the building not only comes from the product. Above all, safety
results from competence. All D+H service and sales partners are certified
and regularly trained specialist SHEV businesses. Working closely with
D+H Mechatronic AG as the manufacturer, they develop comprehensive
system solutions for SHEVs and natural building ventilation. With integral
customer support and continuous quality assurance in all phases of the
project: from sales advice, planning and project management through to
installation, commissioning, repair and service. The highest national and
international quality standards are therefore reliably fulfilled.

The comprehensive network of D+H service and sales partners is at your
disposal to professionally install your system and commission it. Our partner
system guarantees that D+H products are installed exclusively by trained
and experienced fitters, in compliance with the technical guidelines and
specifications. Personal handover and training for users is included.

Maintenance and repair

Quality with guarantee

Always nearby

www.dh-partner.com

Every building operator is responsible for ensuring that its safety equipment
works reliably. Regular and professional maintenance ensures that your
system is always operational. As specialist SHEV businesses, the D+H
service and sales partners are best qualified to carry out maintenance. By
taking out a maintenance contract, operators can prove at all times that they
have fulfilled their obligations.

For all D+H SHEV systems, which have been installed by a D+H service and
sales partner and are regularly serviced, you will receive extended warranty
services. Ask your local D+H service and sales partner about this.

With the network of our own subsidiaries and exclusive partners, we are
represented nearly all over the world.
Are you looking for your local D+H partner?
Simply visit our website:

Introduction

Содержание RZN 43-E Series

Страница 1: ...nstallation commissioning repair and service The highest national and international quality standards are therefore reliably fulfilled The comprehensive network of D H service and sales partners is at...

Страница 2: ...d by D H for carrying out this maintenance competently and will be automatically provided with the latest maintenance instructions Following tests must be carried out during maintenance External exami...

Страница 3: ...heat ventilation system under alarm conditions will occur if the inner temperature exceeds 72 C caused by the radiant heat from a fire in the immediate vicinity of the installation location VE 530 Se...

Страница 4: ...er power lines In case of a cable with green yellow this must Cable and terminal boxes have to be labeled ground wire not be used Slot E1 E2 AM 44 Z Alarm cutoff module TR 42 Cutoff relay module WFR 4...

Страница 5: ...function can be deactivated via the servicetool Attention Reset of the service timer can be carried out by a specialist company only who has been authorized by the appliance manufacturer close red gre...

Страница 6: ...switched OFF ON for Smoke Detector Reset at the control panel This line is released by a line connected in series Every previous plug in slot after the releasing line must be occupied Both the lines...

Страница 7: ...rst to penultimate smoke vent button each Malfunc tion 1 shunt connection by customer Line plug in card LE 513 continuation Parallel connection of RT 45 on LE 513 Terminal resistor for line monitoring...

Страница 8: ...During a period of 30 minutes the smoke vent is triggered at intervals of 2 minutes in accordance with VdS 2581 The group plug in card can be triggered in OPEN direction viaAz signals The group plug i...

Страница 9: ...llel 3 wires for each drive line simple cable length m x total current total consumption 1 2 3 4 5 6 7 8 9 10 A 3x 1 5 mm 120 60 40 30 24 20 17 15 13 12 m 3x 2 5 mm 200 100 65 50 40 33 28 25 22 20 m 5...

Страница 10: ...s overridden in the case of an alarm from the Smoke and heat vent system The function Master CLOSE e g in the case of rain or a timer has a higher priority than the servo function and can be activated...

Страница 11: ...g Mot a Mot b drive with SGI or ZA SG SG I black black orange 2x47kW branch box by customer terminal module EM 47 K LT MOT Mot a Mot b HS SG I SG I SGI 0 10 V 0 10 V SG 0 10 V 0 20 mA 4 20 mA BMS Mot...

Страница 12: ...1 ZMP2 1 2 3 4 5 6 7 8 9 10 11 WE 516 rain wind wind 1 2 4 3 5 7 6 8 9 R W WRG 82 S 1 1 S 1 2 P3 P4 rain wind N AZ ZZ1 T ITR 79 1 6 2 7 4 3 5 230VAC 5 1 3 RTR 230 open close potential free wind rain i...

Страница 13: ...w lock plug in card AE 525 A Function of DIP switches S1 1 on ON failure alarm S1 2 no function DIP switch factory setting DIP switch factory setting Function of DIP switches S1 1 on ON failure alarm...

Страница 14: ...1 Bridge diagnostic pin against middle pin on line plug in card Check fuse connections cables t clamps smoke detectors and external control 2 Bridge diagnostic pin against middle pin on line plug in c...

Страница 15: ...rol panel with reset button 2 Press concealed button in smoke vent button smoke vent closes 3 Red display LED in button and on line plug in unit goes out 1 Trigger external control if available 2 Smok...

Страница 16: ...org Sasse Str 28 32 22949Ammersbek Tel 40 605 65 Fax 40 605 65 254 Germany 49 239 49 E Mail info dh partner com www dh partner com 2010 D H Mechatronic AG Ammersbek Technische nderungen vorbehalten Ri...

Отзывы: