background image

Heatsink

 

ON / OFF

 

A  sound  system  should  be  switched  on 

sequentially. Switch on the self-powered units last 
in your sound system (switch on the subwoofer 
before the mid-high system). Switch on the sound 
sources such as CD players or turntables, then the 
mixer,  then  the  processors, and  finally the  self-
powered  unit.  If  you  have  several  units,  it  is 
recommended  that  you  switch  them  on 
sequentially one at a time.
 

Follow the inverse order when switching off, 

turning  self-powered  units  off  before  any  other 
element in the sound system.

 

Disconnect the device by removing the mains 

connector  from  the  mains  socket.  The  mains 
connector and mains socket must always be freely 
accessible and never covered or blocked in any 
way. 
 

The models use a power cable equipped with 

a Neutrik PowerCon NC3FCA connector. Power 
can be daisy chained (only 

ARTEC-S15A

) via the 

NC3FCB output connector (see details on product 
label).

 

IMPORTANT

:  Do  not  disconnect  the  unit 

while in use.

 

Ensure that the device is disconnected from 

the mains by observing that the ON LED is turned 
off. Please note that the ON LED can stay on for 
several seconds after the mains power has been 
disconnected.

 

Low mains voltage

 

If  mains  voltage  falls  below  the  shutdown 

voltage  for  the  unit,  it  will  stop  playing.  When 
acceptable levels are regained, the unit will switch 
back on automatically.

 

Therefore  the  current  consumed  by  a  115V 

version is double the 230V version to achieve the 
same acoustic power level.

 

Normally it is enough just to let the unit cool 

down after you have corrected the problem so that 
the system functions properly again.
 

Keep grilles clean and dust-free.

 

Do not block or obstruct in any way the air 

entrance or exit while the equipment is in use.
 

Air circulates from the bottom to the top of the 

amplifier.

 

Overheating

 

This  equipment  does  not  normally  overheat 

during normal conditions of use. When overheating 
occurs, the unit protects itself. You should then 
find  out  why  and  if  necessary  contact  an 
authorised dealer for technical assistance.

 

Equalisation

 

The unit does not need extreme settings of 

equalisation to produce quality sound. Avoid high 
levels of gain on the equalisers. Gain values above 
+3 dB on a console’s EQ are not recommended.

 

Overload indicator

 

This device has an indicator (LIMIT LED) that 

lights when the signal is excessive.
 

The  indicator should  not  be  lit  continuously. 

This distorts the signal (quickly fatiguing your ears) 
and may damage the speakers. Therefore, it is 
recommended that you never work with this LED 
on; at most it should blink only occasionally.

Pink Noise

Mains 230 Vrms

1/3  Potencia

1.2A

1.2A

1.2A

1.2A

2A

ARTEC-508A

ARTEC-510A

ARTEC-526A

ARTEC-S15A

15

ARTEC-506A

Manual del Usuario

 / artec 500 series / 

User’s Manual

Содержание ARTEC 500 Series

Страница 1: ...ser s Manual Antes de utilizar el equipo lea la secci n Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions s...

Страница 2: ...WINGS 3 4 5 12 18 17 ACCESSORIES ANNEX CONFIGURATIONS Line connections unbalanced and balanced SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY 14 16 AMPLIFIER Description ON OFF Overload indicat...

Страница 3: ...of a flexible cable already prepared Si el aparato es conectado permanentemente la instalaci n el ctrica del edificio debe incorporar un interruptor multipolar con separaci n de contacto de al menos...

Страница 4: ...araci n en garant a es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defe...

Страница 5: ...Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Cumple con los objetivos esenc...

Страница 6: ...other systems in this market segment High frequencies are handled by the M 60N compression driver with 1 exit and titanium diaphragm offering excellent performance The birch plywood cabinet construct...

Страница 7: ...uction offers an ultra compact design which is available in black or white ARTEC S15A Powered subwoofer system High output 15 louspeaker Loop Thru connections Filtered output defeat switch Variable LP...

Страница 8: ...CONFIGURATIONS 4 x ARTEC 506A 230 1 x ARTEC S15A 230 Standard Configuration DSP 2040 From mixer POWER SUPPLY LINK LINK POWER SUPPLY POWER SUPPLY 8 Manual del Usuario artec 500 series User s Manual...

Страница 9: ...ATIONS cont d 4 x ARTEC 508A 115 2 x ARTEC S15A 115 Standard Configuration DSP 2040 From mixer LINK LINK POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY 9 Manual del Usuario artec 500 series User...

Страница 10: ...TIONS cont d 4 x ARTEC 510A 230 2 x ARTEC S15A 230 Standard Configuration DSP 2040 From mixer LINK POWER SUPPLY POWER SUPPLY LINK POWER SUPPLY POWER SUPPLY 10 Manual del Usuario artec 500 series User...

Страница 11: ...TIONS cont d 4 x ARTEC 526A 115 2 x ARTEC S15A 115 Standard Configuration DSP 2040 From mixer LINK POWER SUPPLY POWER SUPPLY LINK POWER SUPPLY POWER SUPPLY 11 Manual del Usuario artec 500 series User...

Страница 12: ...A ARTEC 508A Bottom View Right View Front View Rear View Rear View Bottom View Right View Front View Rear View Top View Right View Front View Bottom View Right View Front View Rear View Top View Right...

Страница 13: ...z 38 x 19 5 x 25 5 cm 15 x 7 7 x 10 in 9 kg 19 8 lb TRD 2 AXC ZT TRD 6 AXC ZT ANL 2 AXW 1 AXU AR506 AXR AR5 ARTEC 510A 720 W peak 360 W continuous Class D Bi amplified Balanced Differential Line Line...

Страница 14: ...between two types of frequency response 7 LOW PASS CROSSOVER only ARTEC S15A Button for LPF adjustment for subwoofer We recommend 100 Hz 8 MIC LINE Button for switching between microphone and line sen...

Страница 15: ...n acceptable levels are regained the unit will switch back on automatically Therefore the current consumed by a 115V version is double the 230V version to achieve the same acoustic power level Normall...

Страница 16: ...ound system with three phase AC the lighting equipment and the UNIT are connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 Faulty AC cable SOLUTION 1 Check that...

Страница 17: ...only For other wall materials source the suitable wall plug before use DAS Audio Group S L is not responsible for use other than the recommended or whether it be the result of insufficient strength o...

Страница 18: ...n the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanc...

Страница 19: ...8 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134...

Отзывы: